Bard QTEC WALL SLEEVE QWS48A user manual

User manual for the device Bard QTEC WALL SLEEVE QWS48A

Device: Bard QTEC WALL SLEEVE QWS48A
Category: Ventilation Hood
Manufacturer: Bard
Size: 0.22 MB
Added : 4/6/2014
Number of pages: 10
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bard QTEC WALL SLEEVE QWS48A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bard QTEC WALL SLEEVE QWS48A.

For your convenience

If looking through the Bard QTEC WALL SLEEVE QWS48A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bard QTEC WALL SLEEVE QWS48A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bard QTEC WALL SLEEVE QWS48A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bard QTEC WALL SLEEVE QWS48A User manual - Online PDF
Advertisement
« Page 1 of 10 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bard QTEC WALL SLEEVE QWS48A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bard QTEC WALL SLEEVE QWS48A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

QTEC Wall Sleeve
Models: QWS48A
INSTALLATION
QWS48A-16
INSTRUCTIONS
QWS48A-19
QWS48A-23
QWS48A-30
Manual No.: 2100-319F
Bard Manufacturing Company
Supersedes: 2110-319E
Bryan, Ohio 43506
File: Vol. II Tab 14
Since 1914 . . . Moving ahead just as
Date: 11-07-05
planned.
© Copyright 2003
Manual 2100-319F
Page 1 of 10

Summary of the content on the page No. 2

CONTENTS Getting Other Information and Publications 3 Figures QTEC Wall Sleeve General Information Figure 1 Wood Framed Installation ..................... 4 Shipping Damage .................................................. 4 Figure 2 Application of Sealant to 2 x 6 Plate ..... 5 General .................................................................. 4 Figure 3 Application of Sealant to Flanges ......... 5 Installation Instructions Figure 4 Masonry Construction Installation ......... 6 Instal

Summary of the content on the page No. 3

Getting Other Information and Publications These publications can help you install the air FOR MORE INFORMATION, CONTACT THESE conditioner or heat pump. You can usually find these at PUBLISHERS: your local library or purchase them directly from the publisher. Be sure to consult current edition of each ACCA Air Conditioning Contractors of America standard. 1712 New Hampshire Avenue, NW Washington, DC 20009 Telephone: (202) 483-9370 Standard for the Installation of ........... ANSI/NFPA 90A Fax

Summary of the content on the page No. 4

SHIPPING DAMAGE INSTALLATION – WOOD FRAMED WALLS Upon receipt of equipment, the carton should be checked for external signs of shipping damage. If damage is For wood frame construction walls, the dimensions of found, the receiving party must contact the last carrier the opening must be 48 inches tall by 43 inches wide. A immediately, preferably in writing requesting inspection 2 x 6 header will be required for the opening. The sides by the carrier’s agent. of the opening must have trimmer s

Summary of the content on the page No. 5

FIGURE 2 APPLICATION OF SEALANT TO 2 X 6 PLATE SLEEVE OPENING OUTSIDE WALL TREATED 2 X 6 BOTTOM SUPPORT AND SEAL PLATE APPLY CONSTRUCTION APPLY CONSTRUCTION ADHESIVE TO SEAL. ADHESIVE TO SEAL. APPLY CONSTRUCTION ADHESIVE TO SEAL. FRONT VIEW FIGURE 3 APPLICATION OF SEALANT TO FLANGES Manual 2100-319F Page 5 of 10

Summary of the content on the page No. 6

The sleeve is then reinserted into the prepared opening INSTALLATION – MASONRY from the outside of the building. All of the mounting CONSTRUCTION WALLS flanges must contact the exterior wall. Check to see For masonry construction walls, the dimensions for the that there is enough sealant to make this joint opening will be 48-1/4 inches tall by 43-1/4 inches wide. watertight. Additional sealant must be applied as These dimensions are plus or minus 1/4 inch and are necessary. The sleeve must b

Summary of the content on the page No. 7

sealant must be applied as required. The sleeve must be square in the opening. A slope is built into the bottom of the sleeve from the inside to the outside. This will allow anchored to the wall. All four mounting flanges must be fastened with two fasteners each to the outside wall. any water that gets into the sleeve to drain out. Once the test fitting has been checked out, the sleeve should be The gaps between the side flanges, and the top and bottom flanges must be sealed to the wall. re

Summary of the content on the page No. 8

INSTALLATION WITH 16" THICK WALLS INSTALLATION WITH 23" THICK WALLS When an application is required on a building with 16" wall, When an application is required on a building with 23" wall, a Wall Sleeve model number QWS48A-16 is required. a Wall Sleeve model number QWS48A-23 is required. The installation of the QWS48A-16 is similar to the The installation of the QWS48A-23 is similar to the QWS48A with one exception. A condenser fill plate is QWS48A with one exception. A condenser fill plate i

Summary of the content on the page No. 9

drain of the QTEC. This system allows the QTEC unit to ACCESSORY ITEM be installed or removed from the sleeve without The QCDS48 is a condensate disposal system for use on connecting or disconnecting the drain line. all QTEC models. The system consists of a drain box The installation of the QCDS48 requires that a recessed and a rear drain assembly. The drain attaches to the side area next to the sleeve opening be built. See Figure 7 for of the sleeve. The drain box has a rear drain and an di

Summary of the content on the page No. 10

To use this method, discard the two side mounting ATTACHMENT OF WALL SLEEVE TO QTEC UNIT brackets. Remove the nuts and washers from the threaded studs and retain for use later. Remove the All Wall Sleeve Models covered in this manual are lower cabinet door and locate the mating holes in the equipped with two different methods to attach the QTEC rear of the cabinet. It may be necessary to clear the Model being applied. holes of gasket material. The first method is with brackets supplied with t


Alternative user manuals
# User manual Category Download
1 Bard QTEC WALL SLEEVE QWS48A-19 User manual Ventilation Hood 0
2 Bard Economizer with exhaust WGEIFM-5C User manual Ventilation Hood 0
3 Bard QERV-A4B User manual Ventilation Hood 1
4 Bard QTEC WALL SLEEVE QWS48A- 16 User manual Ventilation Hood 0
5 Bard QTEC WALL SLEEVE QWS48A-23 User manual Ventilation Hood 0
6 Bard Economizer with exhaust WGEIFM-3C User manual Ventilation Hood 0
7 Bard Economizer with exhaust WGSEIFM-5 User manual Ventilation Hood 0
8 Bard QERV2-A4B User manual Ventilation Hood 0
9 Bard QTEC WALL SLEEVE QWS48A-30 User manual Ventilation Hood 0
10 Bard Mfg. Co.920-0074 qwserv User manual Ventilation Hood 0
11 Sony SH-L35W User manual Ventilation Hood 0
12 Air King AIF8X User manual Ventilation Hood 3
13 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
14 Air King AIF10X User manual Ventilation Hood 0
15 Agilent Technologies 31A User manual Ventilation Hood 0