Toshiba HV6CS-MLD user manual

User manual for the device Toshiba HV6CS-MLD

Device: Toshiba HV6CS-MLD
Category: Vacuum Cleaner
Manufacturer: Toshiba
Size: 1.06 MB
Added : 7/19/2014
Number of pages: 38
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Toshiba HV6CS-MLD. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Toshiba HV6CS-MLD.

For your convenience

If looking through the Toshiba HV6CS-MLD user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Toshiba HV6CS-MLD on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Toshiba HV6CS-MLD to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Toshiba HV6CS-MLD User manual - Online PDF
Advertisement
« Page 1 of 38 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Toshiba HV6CS-MLD but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Toshiba HV6CS-MLD. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1




Document: GF07Z313




INSTALLATION & OPERATION MANUAL






HV6CS Vacuum Circuit Breakers – Drawout Type
7.2kV Voltage Class







APPLICABLE MODEL NUMBER:




(Motor Operation Type)

HV6CS-MLD


(Drawout Cell)

H6A-HLS













Issued: December, 2012

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Important Notice The instructions contained in this manual are not intended to cover all details or variations in equipment types nor may it provide for every possible contingency concerning the installation, operations, or maintenance of this equipment. Should additional information be required, contact your Toshiba Customer Support Center. The contents of this manual shall not become a part of or modify any prior or existing agreement, commitment, or relationship. The sales con

Summary of the content on the page No. 4

About This Manual Every effort has been made to provide accurate and concise information to you, our customer. At Toshiba International Corporation we are continuously striving for better ways to meet the constantly changing needs of our customers. E-mail your comments, questions, or concerns about this publication to controls@tic.toshiba.com. Purpose and Scope of Manual This manual provides information on how to safely install, operate, maintain, and dispose of your HV6CS brea

Summary of the content on the page No. 5

Contacting TIC’s Customer Support Center Toshiba International Corporation’s Customer Support Center can be contacted to obtain help in resolving any Adjustable Speed Drive system problem that you may experience or to provide application information. The Support Center is open from 8 a.m. to 5 p.m. (CST), Monday through Friday. The Center’s toll free number is US (800) 231-1412/Fax (713) 937-9349 CAN (800) 872-2192 MEX 01 (800) 527-1204. For after-hours support follow the direc

Summary of the content on the page No. 6

Table of Contents General Safety Information ………………………………………………………………………. 1 Safety Alert Symbol ……………………………………………………………………….. 1 Signal Words ………………………………………………………………………………. 1 Equipment Warning Labels ………………………………………………………………. 2 Qualified Personnel ……………………………………………………………………….. 2 Equipment Inspection …………………………………………………………………….. 3 Handling and Storage …………………………………………………………………….. 3 Disposal ……………………………………………………………………………………. 4 During Use ………………………………………………………………………..……………

Summary of the content on the page No. 7

General Safety Information DO NOT attempt to install, operate, maintain, or dispose of this equipment until you have read and understood all of the product safety information and directions that are contained in this manual. Safety Alert Symbol The Safety Alert Symbol is comprised of an equilateral triangle enclosing an exclamation mark. This indicates that a potential personal injury hazard exists. Signal Words Listed below are the signal words that are used throughout this

Summary of the content on the page No. 8

Equipment Warning Labels DO NOT attempt to install, operate, perform maintenance, or dispose of this equipment until you have read and understood all of the product labels and user directions that are contained in this manual. Warning labels that are attached to the equipment will include the exclamation mark within a triangle. DO NOT remove or cover any of these labels. If the labels are damaged or if additional labels are required, contact the Toshiba Customer Support Center. Lab

Summary of the content on the page No. 9

Equipment Inspection • Upon receipt of the equipment, inspect the packaging and equipment for shipping damage. • Carefully unpack the equipment and check for parts that may have been damaged during shipping, missing parts, or concealed damage. If any discrepancies are discovered, it should be noted with the carrier prior to accepting the shipment, if possible. File a claim with the carrier if necessary and immediately notify your Toshiba Customer Support Center. • DO NOT install th

Summary of the content on the page No. 10

Operating the VCB Failure to take the opportunity to discover abnormalities can result in injuries and equipment damage. Always check to make sure that the ON and OFF indicators are correct before operating the equipment. To avoid damaging the equipment, do not close the circuit when the unit switching indicator is ON. Connecting and disconnecting the main circuit To avoid injury and damage to the equipment, do not remove the holding pin unless you are moving the VC

Summary of the content on the page No. 11

During Use Installation location To prevent damage to the VCB or performance degradation, do not store or install it in the following locations: * Places whose ambient temperature is outside the range of -5 C to 40 C (23 F to 104 F). This may result in damage or performance degradation. * Places exceeding 1000 m (3300 ft) elevation. This may result in damage or performance degradation. * Places where excessive dust is produced. This may result in damage

Summary of the content on the page No. 12

Special environmental conditions When using the VCB in special environments, check the points in Table 1 below. Table 1 Points to Check When Using the Circuit Breaker in Special Environments Special Practical example Check points environmental condition Contamination * Large amounts of dust. * Reduce the size of the ventilation duct * Salt corrosion (locations near the * Make sure the wind does not blow seashore or where winds containing directly at the location where the

Summary of the content on the page No. 13

Applicable standards pertaining to switching surges Consult Table 2 for the standards applicable to VCB switching surges. Table 2 Applicable Standards Pertaining to Switching Surges Circuit Load type breaker Rotating Dry type Oil-immersed When there is Phase advance type machine *1 transformer transformer electronic capacitor *4, *5 (insulation (insulation equipment on resistance resistance transformer below class A) low voltage class A) side Ordinary Protected by CR Pr

Summary of the content on the page No. 14

1. Part Names SHAFT FOR MANUAL DRAWOUT CHARGING HANDLE CELL ON-OFF INDICATOR SPRING INDICATOR INTERLOCK LEVER CLOSE LEVER TRIP LEVER VCB COUNTER SECONDARY DRAWOUT DISCONNECTS HANDLES Figure 1 Drawout Type Circuit Breaker - 8 -

Summary of the content on the page No. 15

2. From Receipt to Storage 2.1 Receipt and Unpacking Each VCB unit is carefully tested and inspected prior to shipment, so it can be used as soon as it has been unpacked. However, just in case something should be amiss, you should check the following: (1) When the box is delivered, check to make sure it is not damaged or warped. (2) Remove the unit from the box carefully to avoid damaging it. To prevent injury or damage to the equipment, make sure the unit is CAUTION s

Summary of the content on the page No. 16

Table 5 List of Accessories (Drawout Cell) Part Appearance Quantity Control cable 1* (2m) 2.2 Transport Use the proper procedures when moving or transporting the unit. CAUTION Failure to use the proper (authorized) methods may damage the unit or cause it to fall, resulting in injury. 2.2.1 Transporting U Type VCBs (main circuit terminals on top left and right) Cable Figure 2 Hoisting the Circuit Breaker - 10 -

Summary of the content on the page No. 17

2.2.2 Drawout Cell When hoisting the drawout unit, attach cable (wire rope) to the holes on the left and right of the rear of the unit, as shown in Figure 3. Cable Figure 3 Lifting the Drawout Cell - 11 -

Summary of the content on the page No. 18

2.3 Storage Use the following procedures if the VCB will not be operated for a long period of time after it has been installed, or if it must be stored for a long period of time prior to installation. Be sure to observe the precautions for storage and installation locations (see page 5). (1) When storing the unit, cover it with a dust cover. (2) Avoid locations subject to high humidity or exposed to direct sunlight. (3) Inspect the unit periodically and make sure there are no p

Summary of the content on the page No. 19

3. Installation Make sure the location satisfied the requirements listed under Storage and Installation Location (page 3) and check the dimensions using the diagrams in other catalogs or external view diagrams and panel cut diagram. Prior to installation, the maximum fault current capacity of the power system at the point of installation should be verified. This value must not exceed the symmetrical interrupting capability of the circuit breaker. See typical circuit breaker nameplate

Summary of the content on the page No. 20

Screw Tightening Screw Tightening torque nominal dia. torque Nominal dia. M4 1.47 to 1.96 N-m M8 11.8 to 14.7 N-m (15 to 20 kgf-cm) (120 to 150 kgf-cm) M5 2.94 to 3.92 N-m M10 M10 24.5 to 30.9 N-m (30 to 40 kgf-cm) (250 to 315 kgf-cm) M6 4.90 to 6.37 N-m M12 44.1 to 55.4 N-m (50 to 65 kgf-cm) (450 to 565 kgf-cm) Table 5 Tightening Torque 3.2 Inserting the VCB into the Cell (Outside the cell → disconnected position) Perform the steps shown in Figures 6 through 10 in that ord


Alternative user manuals
# User manual Category Download
1 Toshiba H6A-HLS User manual Vacuum Cleaner 4
2 Toshiba HV6AS User manual Vacuum Cleaner 4
3 Toshiba SR1054HSPCR User manual Vacuum Cleaner 7
4 Toshiba HCV-1JBU User manual Vacuum Cleaner 5
5 Edelbrock 2263 User manual Vacuum Cleaner 0
6 ACS XFC-S User manual Vacuum Cleaner 9
7 Addtron Technology Standard And High Speed Floor Machine P201 User manual Vacuum Cleaner 2
8 AEG ELECTROLUX 460 User manual Vacuum Cleaner 72
9 AEG VAMPYR 825I User manual Vacuum Cleaner 162
10 AEG VAMPYR 731I User manual Vacuum Cleaner 102
11 AEG SMART 301 User manual Vacuum Cleaner 14
12 AEG SMART 300 User manual Vacuum Cleaner 17
13 AEG Z6160 User manual Vacuum Cleaner 3
14 AEG VAMPYR 751I User manual Vacuum Cleaner 36
15 AEG VAMPYR 831I User manual Vacuum Cleaner 19