Summary of the content on the page No. 1
REMOTE CONTROLLER
OWNER’S MANUAL
B-SMA/SMH 09/12/18SC
Single Zone Mini-Splits
B-VMH 09/12/18/24/30/36SC-1
Single Zone Inverter Mini-Splits
B-VMH09/12/18FC-1
Multi-Flex Inverter Mini-Splits
Heat Controller, Inc. • 1900 Wellworth Ave. • Jackson, MI 49203 • (517)787-2100 • www.heatcontroller.com
Summary of the content on the page No. 2
Owner’s Manual Remote ContR olleR Heat Controller, Inc. Table of Contents Using the remote controller ......................................................................................... 2 Remote controller specifications.................................................................................. 3 Function buttons .......................................................................................................... 4 Indicators on LCD display......................................
Summary of the content on the page No. 3
Heat Controller, Inc. Remote ContR olleR Owner’s Manual Using the Remote Controller Use the remote controller within a distance of 26' 3" (8 meters) from the appliance, pointing it towards the receiver. Reception is confirmed by a beep. receiver housing Remove the battery cover by pressing and sliding it off. 2
Summary of the content on the page No. 4
Owner’s Manual Remote ContR olleR Heat Controller, Inc. an extended period of time. Remote Controller Specifications R51l5BG(C)E, R51l6/BG(C)E, R51l7/BG(C)E, R51l8/BG(C)E, R51l9/BG(C)E; Model* R51l10/BG(C)E, R51l11/BG(C)E, R51l12/BG(C)E; Rated Voltage 3.0V (Dry batteries R03/LR03x2 or (2) AAA) Lowest Voltage of CPU Emitting Signal 2.0V Signal Receiving Range 26'3" (8m) Environment -41°F~140°F (-5°C~60°C) *NOTE: Temperature setting display: Fahrenheit scale (°F): R51l9/BG(C)E; R51l10/BG(C)E,
Summary of the content on the page No. 5
Heat Controller, Inc. Remote ContR olleR Owner’s Manual Function Buttons AUTO COOL DRY HEAT* FAN *NOTE: Heat pump models only ION and FOLLOW buttons are optional functions. 4
Summary of the content on the page No. 6
Owner’s Manual Remote ContR olleR Heat Controller, Inc. Function Buttons (continued) ECONOMY Button (Sleep Mode) to maintain the most comfortable temperature TIMER OFF Button ION and FOLLOW buttons are optional functions. Press this recessed button to lock all current set- tings. Use the LOCK mode when you want to prevent settings from being changed accidentally. Press the LOCK button again to cancel the LOCK function. A key symbol will appear on the remote controller display when the lock
Summary of the content on the page No. 7
Heat Controller, Inc. Remote ContR olleR Owner’s Manual Indicators on LCD Display The temperature setting (from 62°F (17°C) to 88°F (30°C)) or timer setting (0~24h) will be displayed. If FAN mode is selected, there will be no display. A key symbol is displayed when pushing the LOCK button. Push the LOCK button to clear display. 6
Summary of the content on the page No. 8
Owner’s Manual REMOTE CONTROLLER Heat Controller, Inc. How to use the buttons Auto operation Ensure power is available to the unit. The OPERATION indicator on the display panel of the indoor unit illumi- nates. 1. Press the MODE button to select Auto. 2. Press the TEMP button to set the desired tempera- ture. The temperature can be set within a range of 2 62°F (17°C)~88°F (30°C) in 2°F (1°C) increments. 3 3. Press the ON/OFF button to start the air conditioner. 1 NOTE 1. In the Auto mode, the
Summary of the content on the page No. 9
Heat Controller, Inc. REMOTE CONTROLLER Owner’s Manual Dehumidifying operation Ensure power is available to the unit. The OPERATION indicator on the display panel of the indoor unit illumi- nates. 1. Press the MODE button to select DRY mode. 2. Press the TEMP button to set the desired tempera- ture. The temperature can be set within a range of 62°F (17°C)~88°F (30°C) in 2°F (1°C) increments. 2 3. Press the ON/OFF button to start the air conditioner. 3 NOTE 1 In the Dehumidifying mode, you can
Summary of the content on the page No. 10
Owner’s Manual Remote ContR olleR Heat Controller, Inc. Pressing the TIMER ON button can set the auto-on time of the unit. And pressing the TIMER OFF button can set the auto-off time of the unit. symbol . SEE NOTE. symbol SEE NOTE ON NEXT PAGE. symbol 9
Summary of the content on the page No. 11
Heat Controller, Inc. Remote ContR olleR Owner’s Manual 10
Summary of the content on the page No. 12
Owner’s Manual Remote ContR olleR Heat Controller, Inc. symbol “h” will 11
Summary of the content on the page No. 13
Heat Controller, Inc. REMOTE CONTROLLER Owner’s Manual ECONOMY (SLEEP MODE) operation When you press the ECONOMY button, the econ- omy/sleep mode running function will be activated, the set temperature will increase (in cooling) or decrease (in heating mode) by 2°F (1°C) over the next 30 minutes and by another 2°F (1°C) after an additional 30 minutes. This new temperature will be maintained for 7 hours before it returns to the originally selected temperature. (NOTE: On some models, the se
Summary of the content on the page No. 14
12/2011