Hunter Fan SPA SELECT 90050 user manual

User manual for the device Hunter Fan SPA SELECT 90050

Device: Hunter Fan SPA SELECT 90050
Category: TV Receiver
Manufacturer: Hunter Fan
Size: 4.02 MB
Added : 4/16/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Hunter Fan SPA SELECT 90050. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Hunter Fan SPA SELECT 90050.

For your convenience

If looking through the Hunter Fan SPA SELECT 90050 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Hunter Fan SPA SELECT 90050 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Hunter Fan SPA SELECT 90050 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Hunter Fan SPA SELECT 90050 User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Hunter Fan SPA SELECT 90050 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Hunter Fan SPA SELECT 90050. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

ENGLISH ES L
See page 2 Vea la página 15
I n s t a l l a t i o n G u i d e
aopñ

90050/90051/90059 Spa Select Bath Ventilator Fan
41717-0105/31/2006
41717-EngS_05.31.06.indd 1 5/31/06 3:53:11 PM

Summary of the content on the page No. 2

W a r n i n g TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING: 1. Use this unit only in a manner intended by the manufacturer. such as those published by the National Fire Prevention If you have questions, contact the manufacturer at the phone Association (NFPA), and the American Society for Heating, number or address listed in the warranty. Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities. 2. Before installing, servicing, or cle

Summary of the content on the page No. 3

Check all the parts. 95047-01-000 95047-01-000 If damaged, call D D 1-888-830-1326 for replacements. 03242-07-133 03242-07-133 E E A A 75192-01-000 * 75192-01-000 * F F 3/8" Cable Connector 3/8" Cable Connector B B 95374-01-000 * 95374-01-000 * G G x3 C 74508-03-133 x3 C 74508-03-133 x2 H x2 H x2 H Extra Screws x2 H Extra Screws 94998-01/02-000 94998-01/02-000 I NOTE: Strain relief cable connector I NOTE: Strain relief cable connector * * must be installed. Not Inclu

Summary of the content on the page No. 4

New Construction Installation A2 A1 D Remove the motor/blower from the housing. Remove tape. A3 A4 Remove the pre-loaded screw tip covers. Remove packing material. A5 A6 E Back out the pre-loaded screw tips until flush with the Remove the wiring cover screw. side of the housing. 41717-01 05/31/2006 41717-01 05/31/2006 4 41717-EngS_05.31.06.indd 4 5/31/06 3:53:15 PM

Summary of the content on the page No. 5

A8 A7 F D Remove the wiring cover. Pop out the first wiring access slug. Use second if needed. A9 A10 D C 5/8 5/8 1/2 1/2 B Insert the strain relief into the housing and secure Position the correct depth mark at the bottom edge with the washer. of the joist–based on the thickness of your sheet rock. OPTION A11 Screw pre-loaded screws into joist or framing. Nail the tabs on both sides to joist or framing so that the housing will be flush with the finished ceiling. Nails are not provided. 41

Summary of the content on the page No. 6

A12 A13 Pull the wires through the strain relief. Tighten the strain relief screws. Ground A14 A15 Green A Bare Copper A A F Black White Connect wires as shown. A0 17 A16 B B D D D F Install the wiring cover plate. Make sure all wiring con- Connect a 4” duct and vent to the outside. Tape joints. nections are inside the box or under the wiring cover plate. If ducting does not fit securely, an adapter may need to be purchased. 41717-01 05/31/2006 41717-01 05/31/2006 6 41717-EngS_05.31

Summary of the content on the page No. 7

ON OFF 0000 A18 A19 0000 D D G G Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. A21 A20 H Secure the motor by tightening the 2 screws. Turn on the power source. A22 A23 I Test the motor. If the motor does not run, Insert one spring clip of the fan cover into the slot on the check the plug connection. motor housing. 41717-01 05/31/2006

Summary of the content on the page No. 8

7.25” A24 I Push the cover into place. Existing Construction Installation D Use the motor housing as a template to mark position. Cut out an opening for the housing. Existing Fan B1 D Remove tape. Remove the existing fan and check to make sure the opening is large enough to accommodate the new motor housing (7.25” x 7.75”). 41717-0105/31/2006 41717-01 05/31/2006 8 41717-EngS_05.31.06.indd 8 5/31/06 3:53:27 PM 7.75”

Summary of the content on the page No. 9

B2 B3 Remove the motor/blower from the housing. Remove packing material. B4 B5 Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush with the side of the housing. B6 B7 F E Remove the wiring cover screw. Remove the wiring cover. 41717-01 05/31/2006 41717-01 05/31/2006 9 41717-EngS_05.31.06.indd 9 5/31/06 3:53:29 PM

Summary of the content on the page No. 10

B9 B8 D C B Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and secure with the washer. B11 B10 D Move the housing into position above the ceiling. Pull the wires through the strain relief and tighten the strain relief screws. B12 B13 D Attach existing ducting to duct connector. Tape joints. Fit housing into the opening and secure by tightening the If ducting does not fit securely, pre-loaded screws into the joist. an adapter may need to

Summary of the content on the page No. 11

B14 B15 Ground Green A Bare Copper D A A Black White Connect the wiring. Connect wires as shown. B16 B17 B D D D E F Install the wiring cover plate. Make sure all wiring Connect wiring from the motor to the wiring cover plate. connections are inside the box or under the wiring cover plate. B19 B18 0000 D H G Reinstall the motor by inserting the tabs and pushing up Secure the motor by tightening the 2 screws. into position. Make sure the wires are not pinched between the motor and the housin

Summary of the content on the page No. 12

ON OFF B20 B21 Test the motor. If the motor does not run, Turn on the power source. check the plug connection. B22 B23 I I Insert one spring clip of the fan cover into the slot Push the cover into place. on the motor housing. 41717-01 05/31/2006 41717-01 05/31/2006 12 41717-EngS_05.31.06.indd 12 5/31/06 3:53:37 PM

Summary of the content on the page No. 13

Trouble Shooting Problem: Fan does not come on. Solution: • Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand near the vents to feel the air movement. • Turn power on, replace fuse, or reset breaker. • Check all plug connections to be sure they are secure. • Check the wiring to make sure it matches the wiring diagram. Problem: Fan is noisy. Solution: • Check and tighten all fasteners. • Check the glass to make sure it is sec

Summary of the content on the page No. 14

Warranty Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any time within one year after the date of sale to you due to a defect in material or workmanship, we will repair or, at our option, replace the defective part free of charge for parts and labor performed

Summary of the content on the page No. 15

E DESDE G u í a d e i n s t a l a c i ó n oapsñ l ™ Ventilador para baño 90050/90051/90059 Spa Select 41717-0205/31/2006 15 41717-Span_05.31.06.indd 15 5/31/06 3:54:37 PM

Summary of the content on the page No. 16

A D V E R T E N C I A PARA REDUCIR EL RIESGO DE DESCARGA ELÉCTRICA O LESIONES, OBSERVE LO SIGUIENTE: normas de seguridad, como las de la Asociación Nacional de 1. Utilice esta unidad sólo de la manera indicada por el fabricante. Protección contra Incendios (NFPA), la Asociación de Ingenieros Si tiene alguna pregunta, contacte con el fabricante en el Americanos en Calefacción y Aire acondicionado (ASHRAE), y teléfono o la dirección indicados en la garantía. los códigos locales.

Summary of the content on the page No. 17

Verifique todos los componentes. 95047-01-000 95047-01-000 Si están dañados, llame al D D 1-888-830-1326 para un reemplazo. 03242-07-133 03242-07-133 E E x4 A A 75192-01-000 * 75192-01-000 F F 3/8" Cable Connector B * B 95374-01-000 * 95374-01-000 Conector de cable de 3/8” G G C x3 * C 74508-03-133 74508-03-133 x2 H x2 H x2 H Extra Screws x2 I Tornillos adicionales 95018-01/02-000 94998-01/02-000 I NOTE: Strain relief cable connector NOTA: Debe estar instalado el I * * must be i

Summary of the content on the page No. 18

Instalación para construcción nueva A2 A1 D Retire la cinta. Retire el motor/soplador del alojamiento. A3 A4 Retire las cubiertas de las puntas de tornillo precargadas. Retire el material de embalaje. A5 A6 E Retire las puntas de tornillo precargadas hasta que estén Retire el tornillo de la cubierta del cableado. a nivel con el lado del alojamiento. 41717-0205/31/2006 41717-02 05/31/2006 18 41717-Span_05.31.06.indd 18 5/31/06 3:54:42 PM

Summary of the content on the page No. 19

A8 A7 F D Retire la cubierta del cableado. Expulse el primer tapón metálico de acceso del cableado. Utilice el segundo si es necesario. A9 A10 D C 5/8 5/8 1/2 1/2 B Introduzca el aliviador de tensiones en el alojamiento y Ubique la correcta marca de profundidad en el borde asegúrelo con la arandela. inferior de la viga, según el espesor de su plancha de yeso. OPCIÓN A11 Clave las pestañas en ambos lados a la viga o al marco de Instale los tornillos precargados en la viga o el marco. modo que

Summary of the content on the page No. 20

A12 A13 Tire de los alambres por el aliviador de tensiones. Apriete los tornillos del aliviador de tensiones. Tierra A14 A15 Verde A Cobre desnudo A A F Negro Blanco Conecte los alambres como se muestra. A0 17 A16 B B D D D F Instale la placa de cubierta del cableado. Asegúrese que Conecte un ducto de 4” y ventile hacia el exterior. Aplique todas las conexiones de cableado estén dentro de la caja cinta a las uniones. Si el ducto no se ajusta firmemente, o debajo de la placa de cubierta del cab


Alternative user manuals
# User manual Category Download
1 Hunter Fan SPA SELECT 90051 User manual TV Receiver 1
2 Hunter Fan SPA SELECT 90059 User manual TV Receiver 0
3 Sony NSX-32GT1 User manual TV Receiver 153
4 Sony DHG-M55CV User manual TV Receiver 0
5 Sony ICS-SP30 User manual TV Receiver 1
6 Adcom GTP-740 User manual TV Receiver 3
7 Addlogix IV-2020 User manual TV Receiver 1
8 Sony HALO LV212 User manual TV Receiver 0
9 Sony HALO LV217 User manual TV Receiver 0
10 Sony HALO AW1 User manual TV Receiver 0
11 Sony HALO LV211 User manual TV Receiver 0
12 Sony HALO DEW210 User manual TV Receiver 0
13 Sony HALO LV216 User manual TV Receiver 0
14 Sony HALO TB216 User manual TV Receiver 0
15 AMX Rough-In Box CB-MVP-WCS52 User manual TV Receiver 0