Summary of the content on the page No. 1
Installation and Assembly:
Flat Panel Pull-out Swivel Wall Mount for 26" - 58"
Screens
Models: SP 850, SP 850P, SP 850-S, SP 850P-S
This product is intended for use with UL
Listed products and must be installed by a
qualified professional installer.
Max Load Capacity: 150 lb (68 kg)
3215 W. North Ave. • Melrose Park, IL 60160 • (800) 729-0307 or (708) 865-8870 • Fax: (708) 865-2941 • www.peerlessmounts.com
ISSUED: 10-12-05 SHEET #: 202-9038-6 05-19-07
Summary of the content on the page No. 2
Note: Read entire instruction sheet before you start installation and assembly. WARNING • Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, please call Peerless customer care at 1-800-729-0307. • This product should only be installed by a qualified professional. • Make sure that the supporting surface will safely support the c
Summary of the content on the page No. 3
Parts List SP850 SP850P SP850-S SP850P-S Description Qty. Part # Part # Part # Part # wall mount assembly 1 201-0385 201-0386 201-0383 201-0384 A B locking tab 1 200-1871 200-1871 200-4871 200-4871 C .219 ID x .5 OD x .125H spacer 1 540-1032 540-1032 540-1032 540-1032 #14 x 2.5" hex head wood screw 4 5S1-015-C03 5S1-015-C03 5S1-015-C03 5S1-015-C03 D Alligator® anchor 4 590-0097 590-0097 590-0097 590-0097 E F 18" polyester mesh sleeve 2 600-1014 600-1014 600-1014 600-1014 G cable tie 4 560-9711 5
Summary of the content on the page No. 4
Installation to Wood Stud Wall WARNING • Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components. Using a stud finder, locate the edges of the wood studs used in mounting this product. Use of an edge-to-edge stud 2 finder is highly recommended. Based on its edges and using a level, draw a vertical line down the center of each stud. Mark a point (point 1) on the right stud centerline where upper right slot will be locat
Summary of the content on the page No. 5
CINDER BLOCK SOLID CONCRETE Installation to Solid Concrete and Cinder Block Wall WARNING • When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifications. It is suggested that a standard electric drill on slow set
Summary of the content on the page No. 6
Place installation tab over sliding arms of wall mount assembly (A) to lock them in place. 3 INSTALLATION TAB SLIDING ARM A FOR INSTALLING TO VESA 100 MM, 200 MM HOLE PATTERN WARNING • If screws don't get three complete turns in the screen inserts or if screws bottom out and adapter plate is still not tightly secured, damage may occur to screen or product may fail. Contact customer care for correct hardware to use. ® Find the VESA hole pattern as shown in figures 4.1 and 4.2, and attach screen t
Summary of the content on the page No. 7
FOR VESA 200 MOUNTING PATTERN: Thread two M4 x 12 mm screws (BB), leaving .25" exposed thread, into top holes on back of screen. Hook screen onto mounting plate, and attach using two bottom M4 x 12 mm screws as shown in figures 4.3 and 4.4. Tighten all four screws. FOR SCREENS WITH VESA MOUNTING PATTERN IN A POCKET: Thread two retaining spacers (L) onto two M4 x 20 mm screws (CC), leaving .25" exposed thread as shown in figure 4.5. Thread M4 x 20 mm screws with retaining spacers into top holes o
Summary of the content on the page No. 8
Slide one mesh sleeve (F) over each cable. Use Optional: To lock mount in closed position, insert 6 7 cable ties (G) to tighten both ends of mesh sleeves one M5 x 40 mm screw (DD) into tapped hole in to cables. either top or bottom of flat plate. Note: loop cable ties through cable mounts and Note: Screen not shown for clarity. tighten cable and mesh sleeve to cable mounts. DD TAPPED HOLE TAPPED HOLE G CABLE MOUNTS FLAT F PLATE Screen can tilt 5° or 10° forward. 8 Note: Screen must be securely a
Summary of the content on the page No. 9
Roll can be adjusted 1° clockwise or Optional: To lock one sliding arm of mount in place, 9 10 counterclockwise. slide locking tab (B) over top or bottom of sliding arm and attach to mount using one M5 x 10 mm screw To adjust roll, loosen screen fasteners slightly, (AA) and one spacer (C). leaving them snug. Level screen, then tighten screen fasteners. Note: Screen not shown for clarity. NOTE: When adjusting roll, screws should be retightened as indicated in step 4. AA B C SLIDING ARM SCREEN FAS
Summary of the content on the page No. 10
Screen Compatibility Chart Manufacturer Screen Manufacturer Model Manufacturer Screen Manufacturer Model Size Size Apex 27" AVL-2776 Sharp 26" IT-26M1U Dell 26" W2600 Sharp 26" LC-26D5U Dell 30" W3000 Sharp 26" LC-26D7U Gateway 26" GTW-L26M103 Sharp 26" LC-26GA4U Gateway 30" GTW-L30M103 Sharp 26" LC-26GD4U Hewlett Packard 30" LC3040N Sharp 26" LC-26GD6U Hyundai 26" HQL260WR Sharp 26" LD-26SH1U Hyundai 32" HQL320WR Sharp 30" LC-30HV2U LG 26" 26LX1D Sharp 30" LC-30HV4U LG 26" RM-26LZ30 Sharp 30" L