Teledyne 200AU-NOy user manual

User manual for the device Teledyne 200AU-NOy

Device: Teledyne 200AU-NOy
Category: TV Converter Box
Manufacturer: Teledyne
Size: 0.53 MB
Added : 8/2/2014
Number of pages: 37
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Teledyne 200AU-NOy. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Teledyne 200AU-NOy.

For your convenience

If looking through the Teledyne 200AU-NOy user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Teledyne 200AU-NOy on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Teledyne 200AU-NOy to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Teledyne 200AU-NOy User manual - Online PDF
Advertisement
« Page 1 of 37 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Teledyne 200AU-NOy but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Teledyne 200AU-NOy. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MANUAL ADDENDUM




M200AU

NOy CONVERTER OPTION
(for use with M200AU Operators Manual, 02293)











Teledyne Advanced Pollution Instrumentation
9480 Carroll Park Dr.
San Diego, CA 92121-5201



TOLL-FREE: 800-324-5190
FAX: 858-657-9818
TEL: 858-657-9800
E-MAIL: api-sales@teledyne.com
WEB SITE: www.teledyne-api.com





02808
REV. E
Copyright 2007 API Inc. July 2007

Summary of the content on the page No. 2

Model 200AU-NOy Option Manual Addendum SAFETY MESSAGES Your safety and the safety of others is very important. We have provided many important safety messages in this manual. Please read these messages carefully. A safety message alerts you to potential hazards that could hurt you or others. Each safety message is associated with a safety alert symbol. These symbols are found in the manual and inside the instrument. The definition of these symbols is described below: General

Summary of the content on the page No. 3

Model 200AU-NOy Option Manual Addendum Table of Contents SAFETY MESSAGES............................................................................................................................................ 2 Table of Contents.................................................................................................................................................... 3 List of Figures ...............................................................................................

Summary of the content on the page No. 4

Model 200AU-NOy Option Manual Addendum 6.1 Operation Verification - M501Y Diagnostic Techniques............................................................................ 31 6.1.1 Pneumatic System..................................................................................................................................... 31 6.1.2 Leak Check ...............................................................................................................................................

Summary of the content on the page No. 5

Model 200AU-NOy Option Manual Addendum List of Figures FIGURE 1.1 - REAR PANEL PNEUMATIC CONNECTIONS ................................................................................. 9 FIGURE 4.1 - CALIBRATION SETUP..................................................................................................................... 16 FIGURE 5.1 - REPLACING THE PARTICULATE FILTER ...................................................................................25 FIGURE 5.2 - CONVERTER

Summary of the content on the page No. 6

Model 200AU-NOy Option Manual Addendum List of Tables TABLE 2.1 - FINAL TEST AND CALIBRATION VALUES.................................................................................. 10 TABLE 4.1 - MANUAL ZERO CALIBRATION PROCEDURE - ZERO GAS THRU SAMPLE PORT............... 17 TABLE 4.2 - ENTER EXPECTED SPAN GAS CONCENTRATIONS PROCEDURE........................................... 18 TABLE 4.3 - SPAN CALIBRATION PROCEDURE.....................................................................

Summary of the content on the page No. 7

Model 200AU-NOy Option Manual Addendum 1.0 Getting Started The M501Y has been designed to operate with the M200AU low level NOx analyzer. The M200AU manual, part number 02293, is a required reference to properly set up and operate this system. 1.1 Unpacking 1. The M200AU with NOy Option comes in three boxes. • The M200AU analyzer • The Bypass Pump Chassis • The External Converter and umbilical cable assembly 2. Verify that there is no apparent shipping damage. If damage has occu

Summary of the content on the page No. 8

Model 200AU-NOy Option Manual Addendum WARNING • Lethal voltages are present inside case • Do not operate with cover off during normal operation • Before operation, check for correct input voltage and frequency. • Do not operate without proper chassis grounding • Do not defeat the ground wire on power plug • Turn off power before disconnecting electrical subassemblies 02808 Rev. E Page 8

Summary of the content on the page No. 9

Model 200AU-NOy Option Manual Addendum Figure 1.1 - Rear Panel Pneumatic Connections 02808 Rev. E Page 9

Summary of the content on the page No. 10

Model 200AU-NOy Option Manual Addendum 1.3 Initial Operation 1. After confirming proper supply voltage, turn on the instrument power. If you are unfamiliar with the M200AU with NOy Option, we recommend that you read the overview in Section 3 before proceeding. 2. The power indicator light and display should immediately light, in addition the bypass pump should start up. The M501Y requires about 30 minutes for the converter to come up to temperature. 3. While the converter is comi

Summary of the content on the page No. 11

Model 200AU-NOy Option Manual Addendum 2.0 Specifications, Warranty 2.1 Specifications Converter Remotely mounted molybdenum converter with temperature controller in a NEMA – 4 enclosure. o o Converter Temperature 315 C ± 7 C with read-out on front panel of bypass pump chassis. Tube/Electrical Cable Up to 50 feet (15 m) maximum length Assembly 120V~ 60 Hz, 230V~ 50 Hz 360 watts Power, Bypass Pump Assembly Power, Converter Assembly 120V~ 50/60 Hz, 60 watts Converter Efficiency >

Summary of the content on the page No. 12

Model 200AU-NOy Option Manual Addendum 2.2 Warranty ADVANCED POLLUTION INSTRUMENTATION, INC. 02024c Prior to shipment, API equipment is thoroughly inspected and tested. Should equipment failure occur, API assures its customers that prompt service and support will be available. COVERAGE After the warranty period and throughout the equipment lifetime, API stands ready to provide on-site or in-plant service at reasonable rates similar to those of other manufacturers in the industry.

Summary of the content on the page No. 13

Model 200AU-NOy Option Manual Addendum 3.0 The M501Y NOy Converter 3.1 Principle of Operation The API Model 200AU with NOy Option is designed to measure the concentration of NO, NO2, and other compounds that are too unstable to be measured when taken in through the normal ambient air sample inlet system. Please refer to Section 4 of the M200AU manual supplied with this system for a general discussion of the operation of a NOx analyzer. The suite of compounds known collectively as NO

Summary of the content on the page No. 14

Summary of the content on the page No. 15

Model 200AU-NOy Option Manual Addendum 4.0 CALIBRATION AND ZERO/SPAN CHECKS Unlike most NOx analyzers, the M200AU with the NOy option does not have a sample inlet port on the rear panel; therefore zero/span calibration is different than a normal NOx instrument. Follow the steps in Section 7 of the M200AU manual to: a. Enter the expected NO and NOx span gas concentrations in the M200AU. b. Do the zero calibration procedure covered in Section 7.1. c. Do the span calibration procedure

Summary of the content on the page No. 16

Model 200AU-NOy Option Manual Addendum NOTE The M200AU with the NOy Option does NOT have equivalency approval, and may not be used for EPA monitoring. Figure 4.1 - Calibration Setup 02808 Rev. E Page 16

Summary of the content on the page No. 17

Model 200AU-NOy Option Manual Addendum 4.1 Calibration or Cal Check Procedure The calibration of the instrument can be checked or adjusted using gas introduced through the calibration port on the Bypass Pump Module. The calibration gas is routed to a TEE near the sample inlet port on the remote converter assembly. Since the zero gas concentration is defined as 0 ppb, it is not necessary to enter the expected zero value. Table 4.1 details the zero calibration procedure. Table 4.1 -

Summary of the content on the page No. 18

Model 200AU-NOy Option Manual Addendum Enter the expected NOx and NO span gas concentrations: Table 4.2 - Enter Expected Span Gas Concentrations Procedure Step Action Comment Number 1. Press This key sequence causes the M200AU to prompt for the CAL-CONC-NOX expected NOx concentration. Enter the NOx span concentration value by pressing the key under each digit until the expected value is set. 2. Press ENTR ENTR stores the expected NOx span value. 3. Press Now enter the expected

Summary of the content on the page No. 19

Model 200AU-NOy Option Manual Addendum Table 4.3 - Span Calibration Procedure Step Action Comment Number 1. Press CAL The M200AU enters the calibrate mode and the adaptive filter is activated. This allows the instrument to respond rapidly to concentration changes regardless of their magnitude. 2. Wait 10 min Wait for reading to stabilize at span value. 3. Press SPAN If you change your mind after pressing SPAN, you can still press EXIT here without spanning the instrument. 4. Pr

Summary of the content on the page No. 20


Alternative user manuals
# User manual Category Download
1 Teledyne 200AH User manual TV Converter Box 0
2 Teledyne 4060 User manual TV Converter Box 1
3 Teledyne gfc 7000t User manual TV Converter Box 0
4 Teledyne pjnmoo385 User manual TV Converter Box 0
5 Teledyne 200EH/EM User manual TV Converter Box 4
6 Teledyne 3190 User manual TV Converter Box 2
7 Teledyne 3020P User manual TV Converter Box 2
8 Teledyne T200U-NOy User manual TV Converter Box 0
9 Teledyne 5000bf User manual TV Converter Box 0
10 Teledyne T101 User manual TV Converter Box 5
11 Teledyne 9110T User manual TV Converter Box 0
12 Teledyne 200A User manual TV Converter Box 0
13 Sony User manual TV Converter Box 2
14 Sony 409 User manual TV Converter Box 0
15 Sony DSBK-1504 User manual TV Converter Box 3
16 Sony BKPF-L752 User manual TV Converter Box 17
17 Sony DSBK-1504P User manual TV Converter Box 2