Summary of the content on the page No. 1
Modular Media Converter Center System
KC-1300
Operation Manual
DOC.060301-KC1300
-1-
Summary of the content on the page No. 2
(C) 2005 KTI Networks Inc. All rights reserved. No part of this documen- tation may be reproduced in any form or by any means or used to make any directive work (such as translation or transformation) without per- mission from KTI Networks Inc. KTI Networks Inc. reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc. to provide notification of such revision or change. For more information, contact: Unite
Summary of the content on the page No. 3
The information contained in this document is subject to change without prior notice. Copyright (C) KTI. All Rights Reserved. TRADEMARKS Ethernet is a registered trademark of Xerox Corp. WARNING: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment genera
Summary of the content on the page No. 4
Table of Contents 1. Introduction ......................................................... 6 1.1 Features ........................................................................................ 7 1.2 Technical Specifications ............................................................... 8 2. Installation ......................................................... 12 2.1 Unpacking .................................................................................... 12 2.2 System Units ...........
Summary of the content on the page No. 5
6.5.1 Basic ......................................................................................... 52 6.5.2 Console Port Information ......................................................... 57 6.5.3 Security Manager ...................................................................... 58 6.5.4 Image Refresh Time ................................................................ 59 6.5.5 Update Firmware...................................................................... 60 6.5.6 Reboot Syste
Summary of the content on the page No. 6
1. Introduction The Modular Converter System KC-1300 is a managed media converter rack that provides 16 slots and hosts 16 units of Media Converter (MC). A wide range of media converters are available depending on your variety of network cabling environment. These optional media converters include Gigabit and Fast Ethernet copper to multimode or single mode fiber cable. The rack unit provides a centered power supply to the converter mod- ules and serves as a converter center and wiring concentr
Summary of the content on the page No. 7
1.1 Features Some of the key features include: Managed Media Converter Center Rack 19-inch rack-mountable 2U chassis Managed system accommodates up to 16 media converters Highly modularized chassis design with - modular media converters - modular management module - two system power modules for power redundancy Provides high availability and maintainability Power backup feature with two power chassis Visible system status indication Supports in-band Telnet, SNMP and web-based man
Summary of the content on the page No. 8
1.2 Technical Specifications System Model KC-1300L/1A KC-1300L/2A KC-1300/1A KC-1300/2A Management support Unmanaged Unmanaged Managed Managed Plug-in power modules 1 AC 2 AC 1 AC 2 AC Input voltage 90~264V 90~264V 90~264V 90~264V Power supply rating 60W 60W 60W 60W Weight (no MC installed) 5.5Kg 6.2Kg 5.5Kg 6.2Kg System Model KC-1300L/1D KC-1300L/2D KC-1300/1D KC-1300/2D Management support Unmanaged Unmanaged Managed Managed Plug-in power modules 1 DC 2 DC 1 DC 2 DC Input voltage -48VDC -48VDC
Summary of the content on the page No. 9
AC Power Chassis Module Specifications Dimension 194mm x 156.6mm x 40.3mm Installation method Plug in from system rear panel Maintenance Modular design for easy maintenance AC power switch System power on/off switch AC power receptacle IEC320 type receptacle Power status indicator Green LED Electric Input voltage rating 100 ~ 240VAC Input voltage range 90 ~ 264VAC Input frequency 47 ~ 63Hz Input surge current 20A max. @115VAC Efficiency 75% @115VAC full load Output power 60W Over current protec
Summary of the content on the page No. 10
Management Module Specifications Dimension 107mm x 24mm x 86.4mm Slot position Slot 0 CPU RISC-based ARM7 RAM size 2M bytes Flash size 512K bytes System interface Connector FutureBus Console interface Interface RS-232 DTE Connector 9-pin male D-SUB connector Baud rate 38400, N, 8, 1, 0 Flow control Disabled In-band interface Interface 10/100M LAN port Connector Shielded RJ-45 MDI Standard IEEE 802.3 10BASE-T/100BASE-TX Auto-negotiation Support LED Indicators P1, P2 Green LED, power module status
Summary of the content on the page No. 11
Management Specifications Management interface Telnet Via direct RS-232 console connection Telnet Via TCP/IP Telnet software SNMP agent Via TCP/IP SNMP manager software HTTP server Via web browser software Protocols IPv4 IP version4 RFC791 TCP Transmission Control Protocol RFC793 UDP User Datagram Protocol RFC768 ICMP Internet Control Message Protocol RFC792 SNMP SNMP agent v1 RFC1157 MIB-II Standard MIB RFC1213 TFTP Trivial File Transfer Protocol RFC1350 TELNET Telnet protocol RFC854 HTTP HTTP
Summary of the content on the page No. 12
2. Installation 2.1 Unpacking The product package contains: The system unit One power cord One 19-inch rack mounting kit Operation Manual 2.2 System Units The figure below illustrates the front view of the KC-1300 system: Depending on the model purchased, the type and numbers of the pre- installed media converters may be different. The figure shows a system which is fully installed with media converters. The following figures show the rear view of the KC-1300 system. The main chassis pro
Summary of the content on the page No. 13
The following figure shows the model equipped with two AC power chassis. Main Chassis : provides insertion slots on front panel for CPU manage- ment module and optional add-on media converters. It also provides two chassis slots on rear for mounting power chassis modules. Management Module : serves as a management agent to monitor system status and add-on converter modules for in-band and out-of-band man- agement requests. Power Chassis : provides full centered power supply for whole system unit
Summary of the content on the page No. 14
2.2.2 Management Module The system unit comes with one pre-installed Management module. The module facilitates the following functions: Direct out-of-band management via RS-232 console port SNMP agent to serve in-band management via SNMP protocol Telnet console in-band management via TCP/IP protocol HTTP host to serve web-based in-band management Monitoring all MCs status installed in the system Monitoring system power and fan status See figure below for major components on the pane
Summary of the content on the page No. 15
Console Port This port is a 9-pin male D-sub connector. It serves as an RS-232 DTE port. Refer to Chapter xx for the console operation. The pin definitions are: Pin2 RXD Pin 3 TXD Pin 4 DTR Pin 5 GND Pin 6 DSR UTP Port This is an auto-negotiation 10/100BASE-TX LAN port and provides a shielded RJ-45 jack with MDI definition. This port must connect to your TCP/IP network for all in-band management operations. LED Indicators Color States Interpretation P1 Green On Power 1 module is ON P2 Green On P
Summary of the content on the page No. 16
2.2.3 Power Chassis Modules The system power supply is assembled in a plug-in chassis module as shown below: Each single power module is capable to supply full power for system operation with media converters fully installed. AC Power Chassis Specifications (KC1300-AC) AC power switch System power on/off switch AC power receptacle IEC320 type receptacle Input voltage range 90 ~ 264VAC Input frequency 47 ~ 63Hz Output power 60W AC power cord IEC320 type power cord Power status display Green LED
Summary of the content on the page No. 17
DC Power Chassis Specifications (KC1300-DC) Input power switch System power on/off switch Input power receptacle Terminal connector (screw type) Input voltage rating -48VDC Input voltage range -48VDC +/-10% Output power 60W Power status display Green LED -17-
Summary of the content on the page No. 18
Removal of System Power Chassis The system power chassis is pre-installed in the system unit when sys- tem unit is shipped from factory. The chassis is designed for easy un- installation from system unit in case of any inspection purpose. How- ever, note that this removal only can be performed by a well-trained technical person. For safety reason before removing the power chassis, make sure: The power switch is turned off. The power cord is disconnected from the power chassis. To remove the
Summary of the content on the page No. 19
Insertion of System Power Chassis Before inserting the power chassis into system unit, make sure: The system power switch is turned off. The power cord is disconnected from the power chassis. To insert the power chassis, hold the handle and push it into system unit until it is seated in system chassis properly. Screw the chassis securely in the system unit. See figure below: The power chassis is designed to be hot plugged into or unplugged from the system even when another power chassis is i
Summary of the content on the page No. 20
2.2.4 Media Converter Slots The system chassis provides sixteen slots for installing optional slide-in MCs. A media converter can be inserted into an available slot or removed from a slot anytime even when system unit is powered on. This hot-plug design keeps all exiting connections on the other slots running with no influence. To insert an MC into a slot, the steps are: 1. Install a bracket, which is provided in the rack chassis package onto the MC unit as shown below: 2. Remove slot cover firs