Black Box LGC300A-R2 user manual

User manual for the device Black Box LGC300A-R2

Device: Black Box LGC300A-R2
Category: TV Converter Box
Manufacturer: Black Box
Size: 0.59 MB
Added : 7/7/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Black Box LGC300A-R2. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Black Box LGC300A-R2.

For your convenience

If looking through the Black Box LGC300A-R2 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Black Box LGC300A-R2 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Black Box LGC300A-R2 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Black Box LGC300A-R2 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Black Box LGC300A-R2 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Black Box LGC300A-R2. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


LGC300A-R2



Industrial SFP/SFP Multi-Power Mode Converter
Converts any fiber optics type interface
to any other fiber optics type interface.

Summary of the content on the page No. 2

FCC and IC RFI Statements FCC and Industry Canada RF Interference Statements Class B Digital Device. This equipment has been tested and found to comply with the limits for a Class B computing device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. This equipment generates, uses, and c

Summary of the content on the page No. 3

Certifications Certifications Class 1 Laser product, Luokan 1 Laserlaite, Laser Klasse 1, Appareil A’Laser de Classe European Directive 2002/96/EC (WEEE) requires that any equipment that bears this symbol on product or packaging must not be disposed of with unsorted municipal waste. This symbol indicates that the equipment should be disposed of separately from regular household waste. It is the consumer’s responsibility to dispose of this and all equipment so marked t

Summary of the content on the page No. 4

Table of Contents Table of Contents Part Numbers ...................................................................................................... 5 1. Specifications ......................................................................................... 6 1.1 Standards/Compliance........................................................................... 6 2. Overview: About the Industrial SFP/SFP Multi-Power Mode Converter.......................................................

Summary of the content on the page No. 5

Part Numbers Part Numbers Part Number Description LGC300A-R2 MultiPower SFP to SFP Mode Converter (SFPs sold separately) LGC300A-R2 724-746-5500 | blackbox.com Page 5

Summary of the content on the page No. 6

Chapter 1: Specifications 1. Specifications DC Input +7 VDC to +50 VDC @ 2.5 watts. Actual current consumption may vary depending on the type of SFP modules installed. When not using the supplied AC/DC converter the externally supplied DC power must be provided from a LPS source. AC Wall Adapter 100 to 240 ±10% VAC input, 5 VDC output @ 2A max. Operating -13°F to +185°F (-25°C to +85°C) DC configuration Temperature +14°F to +122°F (-10°C to +50°C) with Franmar AC wall adapter

Summary of the content on the page No. 7

Chapter 2: Overview 2. Overview: About the Industrial SFP/SFP Multi-Power Mode Converter The Industrial SFP/SFP is a pure mode converter that converts any fiber optics type to any other fiber optics type. This product is a Protocol independent converter and is not intended for applications that require retiming or any Layer 2 functions. The Industrial SFP/SFP supports extended temperature operation. The Industrial SFP/SFP requires two small form-factor (SFP) modules (sold separate

Summary of the content on the page No. 8

Chapter 3: Install the Industrial SFP/SFP Multi-Power Mode Converter 3. Install the Industrial SFP/SFP Multi-Power Mode Converter The Industrial SFP/SFP Multi-Power Mode Converter installs anywhere as a standalone, table-top device or on a DIN rail. As a standalone device, install it in locations with limited space. If multiple connections are required, use an IE-PowerTray/18 enclosure (sold separately). The tray allows for 18 conversions in a 1.5 rack unit of space. The units can

Summary of the content on the page No. 9

Chapter 3: Install the Industrial SFP/SFP Multi-Power Mode Converter • User supplied LPS DC power via a four-position DC power block. • Power from an Power Tray 18-Slot DC For extended temperature operation the DC terminal block must be used because the supplied AC to DC converter is not rated for extended temperature operation. The power source used with the DC terminal block should be a Limited Power Source (LPS). 3.3.1 DC Terminal Block Option The Industrial SFP/SFP DC power opti

Summary of the content on the page No. 10

Chapter 3: Install the Industrial SFP/SFP Multi-Power Mode Converter 3.4 DC Power Supply Precautions The following precautions must be observed when installing the chassis model with an internal DC power supply. 1. Check nameplate ratings to ensure there is no overloading of supply circuits that could effect overcurrent protection and supply wiring. 2. In addition, the following must be observed: a. Connect the equipment to a 35 to 50 VDC power source that is electrically isolated fr

Summary of the content on the page No. 11

Chapter 4: Operation 4. Operation 4.1 LED Operation The Industrial SFP/SFP contains four status LED indicators. Each LED is dual color and has three states: off, red, or green. A loss of signal on one SFP causes the TX of the other SFP to turn off. This action does not activate the red TX Fault LED. LED Color or State Red OFF Green Power is applied to the Card does not pass Unit does not card. the self-test. have power. PWR All internal self-test functions must pass b

Summary of the content on the page No. 12

Chapter 5: Contacting Black Box 5. Contacting Black Box Black Box Customer Service Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) Free technical support, 24 hours a day, 7 days a week. Call: 724-746-5500 or Fax: 724-746-0746 Mail order: Black Box Corporation 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com E-mail: info@blackbox.com WARNING Disconnect all power supplies before servicing. Page 12 724-746-5500 | bla

Summary of the content on the page No. 13

Chapter 6: Fiber Optic Cleaning Guidelines 6. Fiber Optic Cleaning Guidelines Fiber Optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust, which can obstruct the optic path and cause performance degradation. Good system performance requires clean optics and connector ferrules. 1. Use fiber patch cords (or connectors, if you terminate your own fiber) only from a reputable supplier; low-quality components can cause many hard-to- diagno

Summary of the content on the page No. 14

Chapter 7: Electrostatic Discharge Precautions 7. Electrostatic Discharge Precautions Electrostatic discharge (ESD) can cause damage to any product, add-in modules or stand alone units, containing electronic components. Always observe the following precautions when installing or handling these kinds of products. 1. Do not remove unit from its protective packaging until ready to install. 2. Wear an ESD wrist grounding strap before handling any module or component. If the wrist str

Summary of the content on the page No. 15

Notes LGC300A-R2 724-746-5500 | blackbox.com Page 15

Summary of the content on the page No. 16

LGC300A-R2 Rev. 1 55-80619BB-00 Rev. B1


Alternative user manuals
# User manual Category Download
1 Black Box AC217A User manual TV Converter Box 0
2 Black Box 485 User manual TV Converter Box 0
3 Black Box AC095A User manual TV Converter Box 0
4 Black Box Compact Media Converter TP/BNC 50-ohm User manual TV Converter Box 1
5 Black Box MULTIPOWER INDUSTRAL MEDIA CONVERTERS User manual TV Converter Box 2
6 Black Box 422 User manual TV Converter Box 0
7 Black Box 232 User manual TV Converter Box 0
8 Black Box AC215A User manual TV Converter Box 2
9 Black Box DVI-Singlelink AC1038A User manual TV Converter Box 0
10 Black Box LIC022A-R2 User manual TV Converter Box 2
11 Black Box LIC052A-R2 User manual TV Converter Box 0
12 Black Box LIC055A-R2 User manual TV Converter Box 0
13 Black Box LIC025A-R2 User manual TV Converter Box 5
14 Black Box LIC024A-R2 User manual TV Converter Box 0
15 Black Box LIC054A-R2 User manual TV Converter Box 0
16 Sony User manual TV Converter Box 2
17 Sony 409 User manual TV Converter Box 0
18 Sony DSBK-1504 User manual TV Converter Box 3
19 Sony BKPF-L752 User manual TV Converter Box 17
20 Sony DSBK-1504P User manual TV Converter Box 2