Summary of the content on the page No. 1
ROOM AIR CONDITIONER
Use & Care Guide
ACONDICIONADOR DE AIRE PARA HABITACIÓN
Manual de Uso y Cuidado
CLIMATISEUR DE PIÈCE
Guide d’utilisation et d’entretien
Model:
HWR06XCJ
For questions about features, operation/performance, parts,
accessories or service call: 1-877-337-3639
Si tiene preguntas respecto a las características, funcionamiento,
rendimiento, partes, accesorios o servicio técnico,
llame al: 1-877-337-3639
Au Canada, pour assistance, installation ou service,
composez le : 1-877
Summary of the content on the page No. 2
TABLE OF CONTENTS AIR CONDITIONER SAFETY ........................................................3 Using the Remote Control...........................................................11 INSTALLATION REQUIREMENTS.................................................3 Changing Air Direction ................................................................12 Tools and Parts ............................................................................3 Normal Sounds.................................
Summary of the content on the page No. 3
AIR CONDITIONER SAFETY Your safety and the safety of others is very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean: You can be killed or seriously injured if you don't immediat
Summary of the content on the page No. 4
Electrical Requirements Location Requirements IMPORTANT: Observe all governing codes and ordinances. Check the location where the air conditioner will be installed. Make sure you have everything necessary for correct installation. The location should provide: ■ Grounded electrical outlet within 6 ft (183 cm) of where the power cord exits the air conditioner. NOTE: Do not use an extension cord. ■ Free movement of air in room to be cooled. ■ A large enough opening for the air conditi
Summary of the content on the page No. 5
RESET TEST Power Supply Cord NOTE: Your air conditioner’s device may differ from the one shown. A B A. Test button B. Reset button This room air conditioner is equipped with a power supply cord required by UL. This power supply cord contains state-of-the-art To test your power supply cord: electronics that sense current leakage. If the cord is crushed, the electronics detect current leakage and power will be 1. Plug power supply cord into a grounded 3 prong outlet. disconnected in a fraction o
Summary of the content on the page No. 6
NOTE: Your model may differ from the one shown. 3. Slide the side curtain frame into the top channel on the top of the air conditioner and the track on the bottom of the air conditioner. A B 4. Slide the side curtain frame as close to the air conditioner as necessary to lock the side curtain to the frame. A. ¹³⁄₃₂” screws 5. Repeat above steps for the left-hand side curtain and B. Top channel frame. Install Side Curtains NOTE: Attach curtains to the air conditioner before
Summary of the content on the page No. 7
Position Air Conditioner 3. Slide the side bracket over the screw. 4. Tighten the screw. The side bracket should be resting on the windowsill. NOTES: ■ Handle the air conditioner gently. ■ Be sure your air conditioner d oes not fall out of the opening during installation or removal. ■ The place where the power cord exits the air conditioner should be no more than 6 ft (183 cm) from a grounded outlet. ■ Do not block the louvers in the front panel. 5. Use ¹⁄₈” drill bit to d
Summary of the content on the page No. 8
Top View 2. Place the window lock bracket as shown. Use a ¹⁄₈” drill bit to drill a starter hole through the hole in the window lock bracket and into the upper window. 3. Attach the window lock bracket to the upper window with one ³¹⁄₃₂” screw to secure the window in place. 5. Use a ¹⁄₈” drill bit to drill a starter hole through the bottom hole in the side curtain and into the window frame. 6. Insert one of the ³¹⁄₃₂” screws through the bottom hole of the left-hand curtain and
Summary of the content on the page No. 9
AIR CONDITIONER USE Operating your air conditioner properly helps you to obtain the ■ Do not try to operate your air conditioner in the Cool mode when outside temperature is below 61°F (16°C). The inside evaporator best possible results. coil will freeze up, and the air conditioner will not operate prop- This section explains proper air conditioner operation. erly. IMPORTANT: NOTE: In the event of a power failure, your air conditioner will ■ If you turn of f the air conditioner, wait at l
Summary of the content on the page No. 10
To set the Timer to turn on the air conditioner, changing Temperature the previous settings: 1. Turn on the air conditioner. ■ Press the TEMP/TIME up arrow button to raise the 2. Adjust the mode to Fan, Cool, Energy Saver or Dehum. temperature. Each time you press or hold the TEMP/TIME up 3. For Fan, Cool or Energy Saver mode, adjust the fan speed to arrow button, the temperature will go up 1ºF until it reaches High, Med or Low. 86°F (30°C). NOTE: In Dehum mode, the Speed bu
Summary of the content on the page No. 11
Using the Remote Control NOTE: Remote control may differ in appearance. Temperature ■ Press the TEMP/TIME up arrow button to raise the temperature. Each time you press or hold the TEMP/TIME up arrow button, the temperature will go up 1ºF until it reaches 86°F (30°C). ■ Press the TEMP/TIME down arrow button to lower the temperature. Each time you press or hold the TEMP/TIME down arrow button, the temperature will go down 1ºF until it reaches 61°F (16°C). NOTE: One CR2025 battery (
Summary of the content on the page No. 12
4. Adjust the temperature between 61ºF and 86ºF (16ºC and Changing Air Direction 30ºC). NOTE: In Fan mode, the temperature cannot be set. 2-Way Air Flow:The air directional louvers let you control the 5. Wait 3 seconds before turning off the air conditioner. direction of the airflow to the desired direction.The airflow can be 6. Press TIMER. Timer On indicator light on the air conditioner directed left-right. control panel will flash. Display will show remaining hours befo
Summary of the content on the page No. 13
3. Use a vacuum cleaner to clean air filter . If the air filter is very dirty, wash it in warm water with a mild detergent. Do not wash the air filter in the dishwasher or use any chemical cleaners. Air dry the air filter completely before replacing to ensure maximum efficiency. 4. Replace the air filter. 5. Close the front panel. 6. Turn on the air conditioner. Cleaning the Front Panel 1. Turn off the air conditioner. 2. Clean the front panel with a soft, damp cloth. 3. Air dry the
Summary of the content on the page No. 14
■ An extension cord is being used. Do not use an extension Air conditioner cycles on and off too much or does not cord with this or any other appliance. cool room in cooling mode ■ You are trying to restart the air conditioner too soon after turning off the air conditioner. Wait at least 3 minutes after ■ The air conditioner is not pr operly sized for your room. turning off the air conditioner before trying to restart the air Check the cooling capabilities of your room air conditioner.
Summary of the content on the page No. 15
ASSISTANCE OR SERVICE Before calling for assistance or service, please check You can find this information on the model and serial number “Troubleshooting.” It may save you the cost of a service call. If label. See “Electrical Requirements” for the location of the model you still need help, follow the instructions below. and serial number label. Please record the model and serial number information below. When calling, please know the purchase date and the complete Also, record the purchase date
Summary of the content on the page No. 16
LIMITED WARRANTY ONE YEAR LIMITED WARRANTY This warranty covers all defects in workmanship or material for the mechanical and electrical parts (including labor costs) contained in this product for a period of 12 months from the date of purchase. For commercial or rental application, the warranty is 90 days. You must keep and be able to provide your original sales receipt as proof of the date of purchase. FIVE YEAR LIMITED WARRANTY ON THE SEALED SYSTEM The sealed system and compressor (hermetic
Summary of the content on the page No. 17
SEGURIDAD DEL ACONDICIONADOR DE AIRE Su seguridad y la seguridad de los demás es muy importante. Hemos incluido muchos mensajes importantes de seguridad en este manual y en su electrodoméstico. Lea y obedezca siempre todos los mensajes de seguridad. Este es el símbolo de advertencia de seguridad. Este símbolo le llama la atención sobre peligros potenciales que pueden ocasionar la muerte o una lesión a usted y a los demás. Todos los mensajes de seguridad irán a continuación del símbolo de adver
Summary of the content on the page No. 18
Requisitos de ubicación Requisitos eléctricos IMPORTANTE:Observe todos los códigos y reglamentos aplicables. Verifique el lugar donde se instalará el acondicionador de aire. ADVERTENCIA Asegúrese de tener todo lo necesario para una instalación correcta. El lugar debe tener: ■ Contacto con conexión a tierra a no más de 6 pies (183 cm) de donde el cable eléctrico sale del acondicionador de aire. NOTA: No use un cable eléctrico de extensión. Peligro de
Summary of the content on the page No. 19
RESET TEST Para poner a prueba el cable de suministro de energía: Cable de suministro de energía 1. Enchufe el cable de suministro de energía en un tomacorriente de 3 terminales con conexión a tierra. NOTA:El dispositivo de su acondicionador de aire puede ser diferente del que se ilustra. 2. Presione RESET (Reposición) (en algunos aparatos se A encenderá una luz verde). B 3. Presione TEST (Prueba) (escuche el chasquido, el botón de reposición se atrapará y en algunos ap
Summary of the content on the page No. 20
Prepare el acondicionador de aire para la instalación 3. Deslice el marco de la cortina lateral dentro del canal Instale el canal superior superior, en la parte superior del acondicionador de aire, y la vía en la parte inferior del mismo. 1. Coloque el canal superior sobre la parte superior del acondicionador de aire, alineando los orificios en el canal superior con los orificios en la parte superior del acondicionador de aire. 2. Sujete el panel superior al acondicionador de aire