Denon AVR-3805 user manual

User manual for the device Denon AVR-3805

Device: Denon AVR-3805
Category: TV Cables
Manufacturer: Denon
Size: 0.96 MB
Added : 10/4/2014
Number of pages: 15
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Denon AVR-3805. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Denon AVR-3805.

For your convenience

If looking through the Denon AVR-3805 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Denon AVR-3805 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Denon AVR-3805 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Denon AVR-3805 User manual - Online PDF
Advertisement
« Page 1 of 15 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Denon AVR-3805 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Denon AVR-3805. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


DENON AVR/AVC control protocol
Ver. 4.0

Application model : AVR-3805/AVC-3890
Application terminal : RS-232C

Connector specification

Connector type : DB-9pin female type, slave straight connection (DCE type)
( 1pin : GND , 2pin : TxD , 3pin : RxD , 5pin : Common(GND) , 4,6,7,8,9pin : NC )
Communication format :
Synchronous system : Tone step synchronization
communication system : A half duplex
Communication speed : 9600bps
Character length : 8 bits
Parity cont

Summary of the content on the page No. 2

Protocol specification The following three data forms is defined. COMMAND : The message sent to a system(AVR/AVC) from a controller(Touch Panel etc.) A command to a system is given from a controller. EVENT : The message sent to a controller(Touch Panel etc.) from a system(AVR/AVC) The result is sent, when a system is operated directly and a state changes. *The form of EVENT presupposes that it is the same as that of COMMAND. **Refer to the following table for the c

Summary of the content on the page No. 3

The example of a command * is the meaning of 0x0D. SIDVD : Select Input source DVD MSTHX SURROUND EX : surround Mode Set to THX SURROUND EX MVUP : Master Volume UP PWON : system PoWer ON PWSTANDBY : system PoWer STANDBY SI? : Request command for now playing input source >> Return RESPONSE ‘SI***’ - 3 -

Summary of the content on the page No. 4

Others A) COMMAND is receivable also during transmission of EVENT. B) Since CHANNEL VOLUME changes simultaneously when the SURROUND MODE changes, the value of the channel volume of all channels returns as EVENT. C) CHANNEL VOLUME returns the data of ALL channels by the present SURROUND MODE also including an intact channel. In this case, the data of an intact channel is set to "50". D) Since SURROUND MODE changes simultaneously when the INPUT source changes, the SURROUND MODE (and al

Summary of the content on the page No. 5

COMMAND and PARAMETER list COMMAND PARAMETER function example PW ON POWER ON/STANDBY change PWON STANDBY PWSTANDBY MV UP MASTER VOLUME UP/DOWN , direct change to **dB MVUP DOWN MVDOWN ** **:00 to 99 by ASCII , 80=0dB, 99=---(MIN) MV80 CV FL UP CHANNEL VOLUME UP/DOWN , direct change to **dB CVFL UP FL DOWN ---FRONT Lch CVFL DOWN FL ** **:38 to 62 by ASCII , 50=0dB CVFL 50 FR UP CVFR UP FR DOWN ---FRONT Rch CVFR DOWN

Summary of the content on the page No. 6

COMMAND PARAMETER function example CV SB UP ---SURROUND BACKch (SBch 1SP) CVSB UP SB DOWN CVSB DOWN SB ** **:38 to 62 by ASCII , 50=0dB CVSB 50 MU ON OUTPUT MUTE ON/OFF change MUON OFF MUOFF SI PHONO Select INPUT source SIPHONO CD SICD TUNER SITUNER DVD SIDVD VDP SIVDP TV SITV DBS/SAT ---Select DBS function at AVR-3805 SIDBS/SAT VCR-1 SIVCR-1 VCR-2 SIVCR-2 VCR-3 ---

Summary of the content on the page No. 7

COMMAND PARAMETER function example Z2 PHONO MULTI ZONE-2 mode set , and select source at AVR-3805 Z2PHONO | ---The name of PARAMETER is | CDR/TAPE1 the same as that of the time of SI COMMAND. Z2MD/TAPE2 SOURCE MULTI ZONE-2 mode cancel Z2SOURCE UP MULTI ZONE-2 VOLUME UP/DOWN , direct change to ***dB Z2UP DOWN Z2DOWN ** **:00 to 99 by ASCII , 80=0dB, 99=---(MIN) Z280 ON MULTI ZONE-2 ON/OFF change at AVR-3805 Z2ON OFF Z2OF

Summary of the content on the page No. 8

EVENT PARAMETER function example MS DIRECT SURROUND mode set MSDIRECT PURE DIRECT MSPURE DIRECT STEREO MSSTEREO MULTI CH IN MSMULTI CH IN MULTI CH DIRECT MSMULTI CH DIRECT MULTI CH PURE D MSMULTI CH PURE D DOLBY PRO LOGIC All are received as "DOLBY SURROUND" , MSDOLBY PRO LOGIC DOLBY PL2 the surround mode which changed return as EVENT. MSDOLBY PL2 DOLBY PL2x MSDOLBY PL2X DOLBY DIGITAL MSDOLBY DIGITAL DO

Summary of the content on the page No. 9

EVENT PARAMETER function example MS MPEG2 AAC ---Invalid at AVR model MSMPEG2 AAC AAC+DOLBY EX ---Invalid at AVR model MSAAC+DOLBY EX PS TONE DEFEAT ON PARAMETER setting PSTONE DEFEAT ON TONE DEFEAT OFF TONE DEFEAT ON/OFF PSTONE DEFEAT OFF SB:MTRX ON SURROUND BACK SP MODE set PSSB:MTRX ON SB:NON MTRX ---MTRX ON = SURR.EX ON = DSCRT ON PSSB:NON MTRX SB:PL2xCINEMA (@THX) (@ES DSCRT) PSSB:PL2X CINEMA SB:PL2xMUSIC

Summary of the content on the page No. 10

EVENT(or RESPONSE) and PARAMETER list EVENT PARAMETER function example *RES. PW ON POWER ON/STANDBY change PWON STANDBY PWSTANDBY MV ** MASTER VOLUME change , **:00 to 98 by ASCII MV80 98 = +18dB(MAX) 80 = 0dB 00 = -80dB 99 = ---(MIN) CV FL ** CHANNEL VOLUME change , **:38 to 62 by ASCII CVFL 50 FR ** 62 = +12dB(MAX) CVFR 50 C ** 50 = 0dB CVC 50 SW ** 38 = -12d

Summary of the content on the page No. 11

EVENT PARAMETER function example *RES. ZM ON MAIN-ZONE ON/OFF change ZMON OFF ZMOFF Z1 PHONO MULTI ZONE-3 source change Z1PHONO | ---The name of PARAMETER is | CDR/TAPE1 the same as that of the time of SI COMMAND. Z1MD/TAPE2 SOURCE MULTI ZONE-3 mode cancel Z1SOURCE ** MULTI ZONE-3 VOLUME change , **:00 to 99 by ASCII Z180 ? 98 = +18dB(MAX) 80 = 0dB 10 = -70dB 99 = ---(MIN) ON

Summary of the content on the page No. 12

EVENT PARAMETER function example *RES. TF ****** (6 digits) TUNER Frequency change TF105000 --- ****.** kHz at AM band (1050.00kHz at AM) ****.** MHz at FM band TP **(PRESET No.) TUNER PRESET change to No.** TPA1 (PRESET No.”A1”) TM TUNER BAND , MODE change AM ---Band set to AM TMAM ? FM ---Band set to FM TMFM ? AUTO ---Tuning mode set to AUTO mode TMAUTO MANUAL ---Tuning mode set to MANUAL mode TMMANUAL *RES. : NOT

Summary of the content on the page No. 13

EVENT PARAMETER function example *RES. MS DIRECT SURROUND mode change MSDIRECT PURE DIRECT MSPURE DIRECT STEREO MSSTEREO MULTI CH IN MSMULTI CH IN MULTI CH IN MSM CH IN+PL2X C +PL2x CINEMA MULTI CH IN MSM CH IN+PL2X M +PL2x MUSIC MULTI CH DIRECT MSMULTI CH DIRECT MULTI CH DIRECT MSM CH DRCT+PL2X C +PL2x CINEMA MULTI CH DIRECT MSM CH DRCT+PL2X M +PL2x MUSIC MULTI CH PURE D MSMULTI CH PURE D MULTI

Summary of the content on the page No. 14

EVENT PARAMETER function example *RES. DTS NEO:6 CINEMA MSDTS NEO:6 C DTS NEO:6 MUSIC MSDTS NEO:6 M DTS SURROUND MSDTS SURROUND DTS ES DSCRT6.1 MSDTS ES DSCRT6.1 DTS ES MTRX6.1 MSDTS ES MTRX6.1 DTS+PL2x CINEMA MSDTS+PL2X C DTS+PL2x MUSIC MSDTS+PL2X M DOLBY H/P ---Invalid at AVR-3805 MSDOLBY H/P DTS+DOLBY H/P ---Invalid at AVR-3805 MSDTS+DOLBY H/P HOME THX CINEMA ---Invalid at AVR-3805 MSHOME THX CINEMA

Summary of the content on the page No. 15

EVENT PARAMETER function example *RES. PS ROOM EQ:NORMAL ROOM EQ mode change PSROOM EQ:NORMAL ? ROOM EQ:FRONT PSROOM EQ:FRONT ? ROOM EQ:FLAT PSROOM EQ:FLAT ? ROOM EQ:MANUAL PSROOM EQ:MANUAL ? ROOM EQ:OFF PSROOM EQ:OFF ? *RES. : NOT returns '? ' parameters as RESPONSE. - 15 -


Alternative user manuals
# User manual Category Download
1 Denon AVR-3805 User manual Home Theater System 65
2 Denon AVR-3805 User manual Stereo System 234
3 Denon AK-DL1 User manual TV Cables 9
4 Denon AK-HM500/300/100 User manual TV Cables 0
5 Denon AVR-687 User manual TV Cables 11
6 Denon AVR-4802R User manual TV Cables 4
7 Sony DSBK-190 User manual TV Cables 10
8 Sony KE-42M1 User manual TV Cables 5
9 Sony KLV-21SG2 User manual TV Cables 3
10 Sony User manual TV Cables 1
11 Sony XS-AR1023 User manual TV Cables 4
12 Sony BR8K-MF1 User manual TV Cables 1
13 Sony KLV-26HG2 User manual TV Cables 5
14 Sony HXCU-D70 User manual TV Cables 31
15 Sony 408 User manual TV Cables 0