Tripp Lite H2561 user manual

User manual for the device Tripp Lite H2561

Device: Tripp Lite H2561
Category: Telephone
Manufacturer: Tripp Lite
Size: 0.13 MB
Added : 8/20/2014
Number of pages: 15
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Tripp Lite H2561. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Tripp Lite H2561.

For your convenience

If looking through the Tripp Lite H2561 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Tripp Lite H2561 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Tripp Lite H2561 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Tripp Lite H2561 User manual - Online PDF
Advertisement
« Page 1 of 15 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Tripp Lite H2561 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Tripp Lite H2561. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

www.tripplite.com
Practical Power Guidelines for VoIP and
Internet Telephony Applications
by David Slotten
WHITE
PAPER
Cisco, Cisco Systems, the Cisco Systems logo, and the Cisco Square Bridge logo
are registered trademarks or trademarks of Cisco Systems, Inc. and/or its affiliates
95-2914
in the U.S. and certain other countries.

Summary of the content on the page No. 2

Integrate Backup Power into VoIP Networks Voice over IP (VoIP) is exploding in popularity as an application for business data networks. VoIP promises to consolidate a company's data and telecommunications infrastructure as well as its support resources. As a result, a company can lower its hardware and service costs while raising productivity through the use of more elaborate and customizable telephony applications. Unfortunately, there are serious limitations inherent to the data networks that

Summary of the content on the page No. 3

Consider the Diverse Needs of VoIP Network Equipment Before selecting a UPS System to ensure 100% availability of IP telephony systems, it's important to consider the unique requirements of VoIP network equipment. Network designs hosting VoIP applications will vary widely from business to business due to a number of variables, including the scale of the network and the variety of legacy equipment involved. However, three devices are common to all networks: Client Devices (phones, PC-based soft p

Summary of the content on the page No. 4

Select a UPS System which Provides the Highest Availability, Resiliency and Manageability When selecting a UPS System, the most obvious criterion to consider is whether a UPS System has enough capacity (VA/watts) to power equipment while having enough battery capacity to operate during a power outage for your required duration. Specific Tripp Lite UPS System recommendations are listed at the end of this document. Often overlooked during the selection process, however, are more subtle, yet critic

Summary of the content on the page No. 5

Single Power Supply, or Multiple Power Supplies Operating in Redundant Mode STEP 1: Determine Configuration Configuration 1 2 3 4 5 Power Supply PS1 PS1 PS2 PS1 PS2 PS1 & PS2 PS1 PS2 Power Source Wall Wall Wall UPS1 Wall UPS1 UPS1 UPS2 STEP 2: Consider Failure Scenarios STEP 3: Consider System Status PS1 Status Utility Status UPS Status System Status System Status System Status System Status System Status OK OK OK OK OK OK OK OK Failure OK OK Crash OK OK Crash OK OK Blackout OK Crash Crash OK OK

Summary of the content on the page No. 6

B. UPS System Battery Configuration UPS System availability, and therefore VoIP system availability, is most critically dependent upon the capacity of the UPS System's battery configuration. The number of UPS System batteries, both internal and external, determines the amount of runtime that is provided during a power outage. As mentioned previously, the runtime must fit the application. Most existing data networks are unlikely to provide reserve runtime power comparable to the public switched p

Summary of the content on the page No. 7

With power present, a battery system failure will not cause a system interruption. As long as utility power remains present, the UPS System will continue to power the connected IP telephony system without interruption and will continue to condition the power against most power anomalies. In the event of a power outage, the system will crash. In the event of a battery system failure, the internal batteries of the UPS System and/or the external battery packs can be replaced without a service in

Summary of the content on the page No. 8

In the event of a power electronics failure, a service interruption needs to be planned to replace the UPS System. With power present, a battery system failure will not cause a system interruption. As long as utility power remains present, the UPS System will continue to power the connected IP telephony system without interruption and will continue to condition the power against many power anomalies. In the event of a power outage, the system will crash. In the event of a battery system failu

Summary of the content on the page No. 9

adequate. Generally, line-interactive UPS Systems do not pose a problem. This is the subject of some debate and is generally presented as a major issue by vendors biased towards selling online UPS Systems. Line-interactive UPS Systems do tend to cost less than on-line UPS Systems and operate with higher efficiency, reducing electrical costs. In theory, an on-line UPS System battery should be used less frequently due to input voltage variation, and will therefore last longer. This advantage will

Summary of the content on the page No. 10

Alerts available from most UPS Systems and network cards include: � Voltage levels � Current levels � Temperature levels � Humidity levels � Dry contacts for fire, water, security, etc. � Battery capacity � Battery failure Commands from the administrator to most UPS Systems include: � Reboot system � Reboot outlet(s) � Shut down system � Shut down outlet(s) � Run inverter/battery test Tripp Lite presents a uniquely simple management scheme for VoIP UPS System hardware. Whether management is thr

Summary of the content on the page No. 11

Tripp Lite's PowerAlert Software, version 12.5—which is part of an integrated VoIP power solution that includes a Tripp Lite UPS System—has met the Cisco Technology Developer Partner Program test criteria for interoperability with Media Convergence Servers running CallManager, versions 3.3(4) and 4.0(2). Through participation in the Cisco Technology Developer Partner Program, Tripp Lite's integrated VoIP solution provides continuous IP telephony availability to enterprise customers. As an additi

Summary of the content on the page No. 12

Networking Devices (switches, routers, etc.) Networking hardware will typically drive the most significant changes to your existing power infrastructure. With requirements spanning buildings and remote wiring closets, existing facility-wide backup plans are often impractical or unable to address the requirements of mid-size and large switches. Focused UPS System additions with extended runtime battery configurations more efficiently add the high level of availability that VoIP users demand. Trip

Summary of the content on the page No. 13

Call Processing Devices (servers and related storage systems) Typically, additional server and storage resources are added to handle call processing, voice messaging and other telephony applications. Such systems tend to reside within the data center and are multi-vendor in origin. For configuration assistance specific to your rollout, please contact Tripp Lite. Tripp Lite maintains interactive sizing and configuration resources at www.tripplite.com/selector. We also welcome your contact with

Summary of the content on the page No. 14

SmartPro® Line-Interactive UPS Systems Input Nominal Voltage Output Capacity Outlet Outlet Input Plug Model Range Voltage (VA/Watts) Quantity Type Type RU Depth Bypass SMART1500CRMXL 83-145 120 1500/1440 8 8 (5-15R) 5-15P 2U 19 in. Internal SMART2200RMXL2U 120 120 2200/1600 8 4 (5-15R) 5-20P 2U 17 in. None 4 (5-20R) SMART2200CRMXL 83-145 120 2200/1900 8 4 (5-15R) 5-20P 4U 16.75 in. Internal SMART3000RM2U 120 120 3000/2250 9 4 (5-15R) L5-30P 2U 17 in. None 4 (5-20R) 1 (L5-30R) SMART3000CRMXL 83-

Summary of the content on the page No. 15

SmartPro Line-Interactive UPS Systems Half load (Watts) Runtime (minutes) Non-Expandable Battery Pack Expandable Battery Pack* Full Load (Watts) with included batteries 1 2 3 4 BP48V24-2U BP48V48RT4U SMART1500CRMXL Extended Runtime (Non-Expandable) (Expandable) 720 28.5 70.6 195.5 349.2 504.2 658.8 1440 11 28.1 82.1 152 225 299.3 BP48V24-2U BP48V60RT-3U SMART2200RMXL2U Extended Runtime (Non-Expandable) (Expandable) 800 16 62 128 264.3 403.4 542.9 1540 6 24.5 52.6 113 177.3 243.5 BP48V24-2U BP48


Alternative user manuals
# User manual Category Download
1 Tripp Lite H2550 User manual Telephone 2
2 Tripp Lite H2513 User manual Telephone 2
3 Tripp Lite H2551 User manual Telephone 1
4 Tripp Lite H2550EFL16 User manual Telephone 0
5 Tripp Lite H2553 User manual Telephone 1
6 Tripp Lite H2552 User manual Telephone 1
7 Tripp Lite H2550FL16 User manual Telephone 1
8 Tripp Lite H2552EFL28U User manual Telephone 1
9 Tripp Lite H2552FL28 User manual Telephone 1
10 Tripp Lite H2562 User manual Telephone 1
11 Edelbrock 2005-2007 (R) User manual Telephone 0
12 3Com VCX V7000 User manual Telephone 8
13 3Com CommWorks 5210 User manual Telephone 0
14 3Com NBX 900-0208 User manual Telephone 7
15 3Com Analog NBX User manual Telephone 0