Summary of the content on the page No. 1
Magnum Workgroup Hubs
Corporate Headquarters
GarrettCom, Inc. Ten Series
213 Hammond Ave.
Models 1008, 1016 and 1024
Fremont, CA 94539
Phone (510) 438-9071
Fax (510) 438-9072
Website: http://www.GarrettCom.com
email support@garrettcom.com
Installation and User Guide
www .. GarrettCom com www .. GarrettCom com
Summary of the content on the page No. 2
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) Magnum 1008, 1016 and 1024 and optional 48VDC, 24VDC &125VDC-powered models Workgroup Hubs Installation and User Guide Part #: 84-00030 Rev 04/02 Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc. Im
Summary of the content on the page No. 3
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Drive Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.com Federal Communications Commission Radio Frequency Interference Statement This equipment generates, uses and can radiate frequency energy and if not
Summary of the content on the page No. 4
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) TABLE OF CONTENTS Page 1.0 SPECIFICATIONS ......................................................................................................1 1.1 Technical Specifications......................................................................................1 1.2 Specifications - Repeater Port Module (RPM) ..................................................2 1.3 Specifications - Bridge Port Module (BPM)................
Summary of the content on the page No. 5
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) Revisions Rev D 04/02 : Included Power Budget calculation and Rack mounting as well as updated Appendix B with 24VDC & 125VDC option. Rev C 04/01 : Change the company name to GarrettCom, Inc. (Formerly it was Garrett Communications). There are no changes to the content of the material at this time Rev B 06/99: This revision changed the company address to the new location and added the 48V Appendix B. Rev A 06/95 : This r
Summary of the content on the page No. 6
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) The Magnum Line ETHERNET CONNECTIVITY PRODUCTS "DESIGNED AND MANUFACTURED IN THE USA" OVERVIEW GarrettCom, Inc.offers the premium-quality Magnum line of Ethernet LAN connectivity products with industry-standard functionality and built-in fiber configurability. Magnum products are designed for use in demanding Carrier Class, Industrial Grade and OEM applications where reliability is a primary consideration
Summary of the content on the page No. 7
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) 1.0 SPECIFICATIONS 1.1 Technical Specifications Performance Data Rate: 10Mbits / sec Partitioning: Enforced after 32 consecutive collisions. Reconnect: Occurs after 512 bits of error-free transmission. Network Standards Ethernet V1.0/V2.0 IEEE 802.3: 10BASE-T, 10BASE5, 10BASE2, 10BASE-FL & FOIRL. (Magnum Workgroup Hubs are physical layer standard Ethernet products, and operate independently of all software.) Maxi
Summary of the content on the page No. 8
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) Power Supply (Internal) AC Power Connector: IEC-type, male recessed, rear of chassis Input Voltage: 90 to 260 VAC (auto-ranging) Input Frequency: 47 to 63 Hz (auto-ranging) Power Consumption: 10 watts typical, 20 watts max. P.S. rating (For 48VDC power input option, see Appendix B). Agency Approvals UL Listed (UL 1950), cUL, CE Emissions meet FCC Part 15 Class A Warranty Three years, return to factory Made in USA 1.
Summary of the content on the page No. 9
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) 1.4 Ordering Information Magnum 1000 Workgroup Hubs Magnum 1008 Eight port 10BASE-T Hub with shielded RJ-45 connectors and front-mounted LEDs. Includes a basic AUI port in the rear; may optionally be ordered instead with an RPM or BPM in the rear port slot. Internal universal power supply, up-link switch on port 1. Stand-alone package, rack-mount brackets optional. Magnum 1016 16 port 10BASE-T Hub with shielded RJ-45
Summary of the content on the page No. 10
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) 2.0 INTRODUCTION 2.1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage which you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included. This package should contain: 1 Magnum 1008, 1016 or 1024 Workgroup Hub 1 Set of
Summary of the content on the page No. 11
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) The family of Magnum 1000 Workgroup Hubs is comprised of Models 1008 (pronounced ten oh-eight), 1016 (ten sixteen) and 1024 (ten twenty-four). These models are equipped with 8, 16 or 24 front-mounted, shielded RJ-45 ports, respectively. Magnum 1000 Workgroup Hubs support full Ethernet segment lengths and operate in compliance with the IEEE 802.3 specification for repeater functionality to perform signal amplificat
Summary of the content on the page No. 12
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) AC Power 115 - 230 VAC Basic AUI Port Figure 2.2.1b: Rear view - Magnum 1008 Workgroup Hub with the basic AUI port As an alternative to the basic AUI port, it is possible (at the time of initial order) to replace the basic AUI rear port with any Magnum Port Module (PM). (See Figure 2.2.1c). This option gives the Magnum 1008 great flexibility to easily conform to any standard Ethernet media environment. When configure
Summary of the content on the page No. 13
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) Magnum 1024 Workgroup Hub 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 GARRETT Figure 2.2.2b: Front view - Magnum 1024 Workgroup Hub In the rear, the basic AUI (standard female) port, shown in Figure 2.2.2c, may be used for a direct connection with
Summary of the content on the page No. 14
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) 2.3 Internal Connections, basic AUI Port and Port Modules Figure 2.3a shows the internal layout of the Magnum 1008 for each of the two rear port configuration options (see section 2.2.1). Unless otherwise specified at the time of order, the Magnum 1008 is shipped with a basic AUI port. For greater application flexibility, any of the Magnum PMs may be specified at the time of order for factory configuration. It is also
Summary of the content on the page No. 15
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) Bonus port for optional Basic AUI port PM card (BPM shown) J1-RPM J1 J4-RPM J4 J4-RPM J4 NOTE: PM Ribbon cable with 16 pin headers. Use J1 and J4 for Basic AUI ports (Included only when PM is factory installed. Use J1-RPM and J4-RPM for PMs May be ordered separately as part # CBL-PM) Figure 2.3b: Model 1024 Internal Connections, Basic AUI port and Bonus Port 2.4 Bonus Port Configuration Options - RPMs and BPMs Magnum 10
Summary of the content on the page No. 16
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) BPMs are available for the following four Ethernet media connector types: BNC (ThinNet or 10BASE2), AUI (10BASE5 or ThickNet, DB-15 female for most transceiver connections), ST (Ethernet multi-mode Fiber ST), and RJ-45 (10BASE-T UTP and STP). They are shown in Figure 2.4b. Figure 2.4b: Magnum BPM Cards: BPM-TP, BPM-BNC, BPM- ST, BPM-AUI Magnum Port Modules provide an optional electronic assembly and media connector fo
Summary of the content on the page No. 17
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) 2.4.1 RPM-BNC The Magnum RPM-BNC repeater module is equipped with a standard 10BASE2 coax connector. This RPM performs full IEEE 802.3 repeater functionality and is used for 10BASE2 ThinNet (commonly referred to as BNC) connections. The RPM-BNC module is designed with a special switch-selectable internal termination function that eliminates the need for a "tee" connector and a 50 ohm terminator. To take advantage of i
Summary of the content on the page No. 18
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) used with a variety of different mini-transceivers to provide connectivity to any media type. The RPM-AUI card is equipped with Partition (PART) and Receive (RX) LEDs. The RX LED functions the same as the RX LEDs of the RPM-BNC. The PART LED is inoperative on Model 1000 Workgroup Hubs. (Section 2.4.1 above). The Magnum RPM-AUI Partition LED Standard 15-pin 1 card is also used for connecting female AUI, 2 Receive LED w
Summary of the content on the page No. 19
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) 2.4.4 RPM-FST (Fiber ST, Twist-lock Connector) The Magnum RPM-FST is a multi-mode fiber optic module equipped with a dual ST-type connector. It functions as an IEEE 802.3 full repeater to support 10BASE- FL and FOIRL network segments. When used for 10BASE-FL segments, this module supports fiber optic transmission 10BASE-FL, FOIRL distances up to 2000m. For FOIRL ST Connectors applications, it supports fiber segment
Summary of the content on the page No. 20
Magnum 1000 Workgroup Hubs Installation and User Guide (04/02) 2.4.6 RPM-SMF (Single-mode Fiber) The Magnum RPM-SMF is a single-mode fiber optic module equipped with a dual ST-type connector. It functions as a full repeater to support single-mode fiber networks. The RPM-SMF supports fiber optic transmission distances of up to 10 Km. The RPM-SMF includes full Single-mode ST Connectors transceiver functionality and does not require an external transceiver device. 1 This module i