Device: Emerson 200I/48-NT5C05C
Category: Switch
Manufacturer: Emerson
Size: 0.34 MB
Added : 10/30/2014
Number of pages: 62
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson 200I/48-NT5C05C. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson 200I/48-NT5C05C.

For your convenience

If looking through the Emerson 200I/48-NT5C05C user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson 200I/48-NT5C05C on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson 200I/48-NT5C05C to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson 200I/48-NT5C05C User manual - Online PDF
Advertisement
« Page 1 of 62 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson 200I/48-NT5C05C but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson 200I/48-NT5C05C. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 8

8 Contents 6. Maintenance................................................................................................. 49 6.1. Replacing the air filter ................................................................................ 49 6.2. Replacing the fan unit ................................................................................ 49 6.3. Calibrating the Volt / Amp Multimeter......................................................... 50 6.4. Resetting the rectifier after an

Summary of the content on the page No. 9

Contents 9 Procedure 6 - Connecting the ac male plug between the NT5C05CC rectifier and the ac female plug in a 1200 A cabinet .................................. 27 Procedure 7 - Connecting the NT5C05CC to the controller................................. 28 Procedure 8 - Connecting an NT5C05CC rectifier directly to a controller ........... 29 Procedure 9 - Starting up the rectifier .................................................................. 46 Procedure 10 - Replacing the fan unit

Summary of the content on the page No. 10

10 Contents This page is left blank intentionally. UM5C05C P0745680 Standard 6.00 October 2001 Emerson Energy Systems

Summary of the content on the page No. 11

11 1. General information 1.1. Purpose of this manual This manual provides installation, operation and maintenance information for the NT5C05CA / CB / CC 200I modular switch mode rectifiers with an input voltage of 380 / 415 V ac and an output capacity of 200 A at a nominal voltage of –48 volts. This manual covers all applications of the rectifier referred to as the 200I ( “I” standing for “International” ) market. Figure 1 - Front view of the modular 200I / 48 switch mode rectifier H

Summary of the content on the page No. 12

12 General information 1.2. Models and mounting configurations Two models of 200I rectifiers are available : • Models NT5C05CA / CB, without an ac cable • Model NT5C05CC, equipped with an ac cable terminated with a male plug Up to six switch mode 200I rectifiers can be installed in a 23-inch NT6C43CB 1200 A cabinet or in an NT6C40 type frame. The cabinet is specifically designed to provide modularity within a very compact unit. For wooden floor applications in a zone 4 seismic region,

Summary of the content on the page No. 13

13 2. Specifications 2.1. Mechanical and electrical specifications Table 1 - Mechanical specifications of the rectifier 10.0 inches ( 25.4 cm ) Height : Depth : 22.0 inches ( 55.9 cm ) Width : 20.5 inches ( 52.1 cm ) Weight : 92.6 lbs ( 42 kg ) Table 2 - Electrical specifications of the rectifier Input voltage : Nominal : 380 / 415 V ac Range : 330 ±5 V ac to 475 ±5 V ac Frequency : 47 to 63 Hz Note: After an out of range line condition shutdown, the rectifiers will restart automat

Summary of the content on the page No. 1

Emerson Energy Systems
UM5C05C ( 169-2081-501 )
Helios Modular Switch Mode Rectifier
200I/48NT5C05C
Installation and User Manual






HE LI O S
V O L T
V OL T
C A L
C U R
A M P
C A L
C L
I
AD J
EQ L
AD J
S E N

TH S D RF A A C ON E QL
F A IL
FF 1 F F2
F L T
1 .0 A 1 .0A
0 FA N
H V S D E Q L C L
A L M
F LT
A DJ
A C/ C A
V O L T+ V O U T -
H VS D
A D J
I
S T U P
D L Y
S L S F S
I
D C / C C







P0745680 Standard 6.00 October 2001

Summary of the content on the page No. 14

14 Specifications 2.2. Operation specifications and ambient conditions Table 3 - Operation specifications of the rectifier At the output terminals, the voltage is within ±0.5% of Output regulation : the set voltage value for all specified input and output variations, and within ±1% for any combination of specified input, output and ambient conditions. Unless otherwise stated, all input and output Temperature drift : parameters such as input voltage range, output current and voltage,

Summary of the content on the page No. 15

Specifications 15 Table 4 - Ambient conditions for the rectifier Operating A minimum airflow clearance of 2 inches ( 5 cm ) is required at the rear of the rectifier. conditions The rectifier will operate properly under the following conditions. Temperature: 32°F to 122°F ( 0°C to +50°C ) 32°F to 104°F ( 0°C to +40°C ) with air filters Humidity: 0 to 95% RH ( non-condensing ) at 4 kPa max. equiv. to 7,000 ft. ( 2,100 m ) above sea level Transportation During transportation, the

Summary of the content on the page No. 16

16 Specifications 2.3. Mechanical and electrical specifications of a 1200 A cabinet Table 5 - Mechanical specifications of the NT6C43CB 1200 A cabinet 84.00 inches ( 213.36 cm ) Height : Depth : 23.63 inches ( 60.0 cm ) 23.63 inches ( 60.0 cm ) Width : Table 6 - Electrical specifications of the NT6C43CB 1200 A cabinet Input voltage : 380 / 415 V ac three phase Output voltage : –46 V dc to –58 V dc Output current : 1200 A 2.4. Ambient conditions of a 1200 A cabinet Table 7 — Ambien

Summary of the content on the page No. 17

17 3. Installation 3.1. Mounting configurations The NT5C05CA / CB / CC rectifiers are designed for installation in a 1200 A cabinet ( NT6C43CB ) or in a standard frame ( NT6C40 or equivalent ). In this chapter, a different procedure is provided for each mounting method. The rectifiers are shipped loose, not mounted in the frame or cabinet. Upon reception, remove the rectifier from its shipping carton and inspect it for physical damage. Report any damage to your immediate supervisor. 3.

Summary of the content on the page No. 18

18 Installation CAUTION Preventing damage caused by over-tightening Do not over-tighten nuts and bolts. Over-tightening can strip the threads or break the bolts. Apply the appropriate torque values. CAUTION Personal safety and protecting the equipment Use a dolly truck, forklift, or hoist whenever possible when handling and moving the equipment, as power equipment is heavy. If a forklift is used, do not remove the packing material before having moved the equipment to its fi

Summary of the content on the page No. 19

Installation 19 WARNING Generator requirements for Emerson Energy Systems Power Systems For information on selecting ac generators that will effectively maintain peak performance and operating characteristics, for all Astec APS power systems, go to the partners’ section of the Emerson Energy Systems web site at www.EmersonEnergy-NA.com. To obtain access to the partners’ section follow the instructions found on the partner’ page, or dial our nearest local 1−800 technical support li

Summary of the content on the page No. 20

20 Installation DANGER Short circuit hazard The rectifiers, and the batteries in particular, can deliver high current if a short to ground occurs. When working on live equipment, remove all personal jewellery, use properly insulated tools, and cover any live busbars with a insulating sheet of canvas to prevent short circuits that could be caused by falling tools or parts. 3.3.1. Installing in a frame When shipped, the NT5C05CA / CB / CC switch mode rectifiers are configured for

Summary of the content on the page No. 2

Summary of the content on the page No. 3

3 Helios Modular Switch Mode Rectifier 200I/48 NT5C05C   Installation and User Manual Manual Number : UM5C05C ( 169-2081-501 ) Manual Status : Standard Manual Issue : 6.00 Release Date : October 2001 P0745680 Copyright  2001 Astec International Ltd All Rights Reserved Published in Canada The information contained in this manual is the property of Astec International Ltd and is subject to change without notice. Astec International

Summary of the content on the page No. 4

Summary of the content on the page No. 5

5 Publication history October 2001 Standard Issue 6.00. Manual restructured and updated to reflect Emerson Energy Systems and Emerson Network Power identities. ( ECN 102-26804 ) March 1998 Issue 5.0. Standard. Reference change from NT5C05CB to NT5C05C. July 1997 Issue 4.0. Standard EMI compliance information and table of content numbering corrections. June 1995 Issue 3.0. Standard. Revised rectifier installation procedure in a cabinet. September 1994 Issue 2.0. Standard. Few revisio

Summary of the content on the page No. 6

6 Publication history This page is left blank intentionally. UM5C05C P0745680 Standard 6.00 October 2001 Emerson Energy Systems

Summary of the content on the page No. 7

7 Contents 1. General information .................................................................................... 11 1.1. Purpose of this manual .............................................................................. 11 1.2. Models and mounting configurations ......................................................... 12 2. Specifications .............................................................................................. 13 2.1. Mechanical and electrical specifications


Alternative user manuals
# User manual Category Download
1 Emerson 5081-T User manual Switch 38
2 Emerson ASCO 300 Series User manual Switch 747
3 Emerson ASCO 7000 User manual Switch 91
4 Emerson 7000 User manual Switch 58
5 Emerson ASCO 185 User manual Switch 45
6 Emerson 7ADTB User manual Switch 3
7 Emerson 185 User manual Switch 7
8 Emerson B-294 HD User manual Switch 0
9 Emerson Autochangeover Controllers AC8 User manual Switch 7
10 Emerson 214A401 User manual Switch 0
11 Emerson 214A400 User manual Switch 3
12 Emerson 214A404 User manual Switch 0
13 Emerson 260 User manual Switch 0
14 Emerson 300 User manual Switch 1
15 Emerson 386 User manual Switch 0
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4