Title Page
WPIM-T1/DDS
User’s Guide
T1
DDS
WPIM
T1/DDS
9032750
Summary of the content on the page No. 2
Summary of the content on the page No. 3
Only qualified personnel should perform installation procedures. NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR AN
Summary of the content on the page No. 4
Notice INDUSTRY CANADA NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Cana
Summary of the content on the page No. 5
Notice CABLETRON SYSTEMS, INC. PROGRAM LICENSE AGREEMENT IMPORTANT: Before utilizing this product, carefully read this License Agreement. This document is an agreement between you, the end user, and Cabletron Systems, Inc. (“Cabletron”) that sets forth your rights and obligations with respect to the Cabletron software program (the “Program”) contained in this package. The Program may be contained in firmware, chips or other media. BY UTILIZING THE ENCLOSED PRODUCT, YOU ARE AGREEING T
Summary of the content on the page No. 6
Notice UNITED STATES GOVERNMENT RESTRICTED RIGHTS The enclosed product (a) was developed solely at private expense; (b) contains “restricted computer software” submitted with restricted rights in accordance with Section 52227-19 (a) through (d) of the Commercial Computer Software - Restricted Rights Clause and its successors, and (c) in all respects is proprietary data belonging to Cabletron and/or its suppliers. For Department of Defense units, the product is licensed with “Restricted R
Summary of the content on the page No. 7
Notice DECLARATION OF CONFORMITY Application of Council Directive(s): 89/336/EEC 73/23/EEC Manufacturer’s Name: Cabletron Systems, Inc. Manufacturer’s Address: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representative Name: Mr. J. Solari European Representative Address: Cabletron Systems Limited Nexus House, Newbury Business Park London Road, Newbury Berkshire RG13 2PZ, England Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC EC Dir
Summary of the content on the page No. 8
Notice vi WPIM-T1/DDS User’s Guide
Summary of the content on the page No. 9
CONTENTS INTRODUCTION......................................................................................ix Using This Manual..........................................................................ix Structure of This Guide...................................................................ix Related Manuals..............................................................................x Document Conventions ..................................................................xi Getting
Summary of the content on the page No. 10
Contents 3.3 Full T-1 Configuration Using PPP ..............................................3-11 3.3.1 T1 Service Physical Configuration ................................3-12 3.3.2 T1 Interface Configuration.............................................3-13 3.4 Fractional T-1 Configuration Using PPP ....................................3-14 3.4.1 T1 Physical Configuration .............................................3-15 3.4.2 T1 Interface Configuration......................................
Summary of the content on the page No. 11
INTRODUCTION Welcome to the Cabletron Systems WPIM-T1/DDS User’s Guide. This manual provides hardware information and explains the use of Local Management to control and manage the Cabletron Systems WPIM-T1/DDS. The WPIM-T1/DDS is installed in and provides connectivity and functionality to the CSX400 and the HSIM-W6. The WPIM-T1/DDS provides full or fractional T1, or a DDS interface to these platforms. The WPIM-T1/DDS uses the same connector to provide T1 and DDS conne
Summary of the content on the page No. 12
Introduction Chapter 3, Local Management for T1 Service, describes how to use Local Management to set up T1 service with the WPIM-T1/DDS. Chapter 4, Local Management for DDS Service, describes how to use Local Management to set up DDS service with the WPIM-T1/DDS. Appendix A, Specifications, provides information on physical properties, environmental requirements, regulatory compliance, pinouts and LED definitions. Appendix B, FCC Part 68 - User’s Information, expla
Summary of the content on the page No. 13
Introduction DOCUMENT CONVENTIONS The following conventions are used throughout this document: Note symbol. Calls the reader’s attention to any item of NOTE information that may be of special importance. Tip symbol. Conveys helpful hints concerning procedures or TIP actions. Caution symbol. Contains information essential to avoid damage to the equipment. ! CAUTION Electrical Hazard Warning symbol. Warns against an action that could result in personal injury or death due
Summary of the content on the page No. 14
Introduction n Indicates the generic use of a number. (e.g., 19nn indicates a four-digit number in which the last two digits are unknown.) [] In the Local Management screens, the brackets indicate that a value may be entered or selected. In the format descriptions in the Network Tools section, required arguments are enclosed in []. <> In the format descriptions in the Network Tools section, optional arguments are enclosed in <>. GETTING HELP For additional su
Summary of the content on the page No. 15
CHAPTER 1 OVERVIEW This chapter describes the features of the WPIM-T1/DDS. It also briefly explains the WAN protocols supported by the WPIM-T1/DDS. Some steps for successful operation of this device are: • Install the WPIM-T1/DDS in a Wide Area Network host platform. Refer to Chapter 2 for direction on installation procedures. Refer to the appropriate host manual (i.e., the Cabletron Systems CyberSWITCH CSX400 and CSX400-DC Installation Guide for other installation and troubl
Summary of the content on the page No. 16
Chapter 1: Overview 1.1 FIRMWARE REVISION Important Notice Depending on the firmware version used in the WPIM-T1/DDS, some features described in this document may not be supported. Refer to the Release Notes shipped with the WPIM-T1/DDS to determine which features are supported. This manual covers Firmware Revision level 02.01.XX. Later revisions may be reflected in an updated manual. Please check carefully to verify the revision level of your device, to ensure that this manual
Summary of the content on the page No. 17
WAN Protocols A connection can only be chosen for either T1 or DDS service NOTE in Local Management. Both services cannot operate at the same time. 1.3 WAN PROTOCOLS The module in which the WPIM-T1/DDS is installed supports the following WAN protocols (refer to the Release Notes included with the host MIM or standalone hub for a list of current protocols): • Point to Point Protocol (PPP) and as defined by RFC 1661 • Frame Relay as defined by RFC 1490 • ISDN as defined by Q.921 and Q.931 1.4 MIB
Summary of the content on the page No. 18
Chapter 1: Overview 1-4 WPIM-T1/DDS User’s Guide
Summary of the content on the page No. 19
CHAPTER 2 SETUP AND INSTALLATION Only qualified personnel should install the WPIM-T1/DDS. This User’s Guide is intended for the experienced network equipment installer. This chapter details set up and installation of the WPIM-T1/DDS into a host platform. QuickSET or Local Management must be used to set up the NOTE WPIM-T1/DDS in management before any connections are made to the WAN. Follow the directions carefully. 2.1 INSTALLING THE WPIM-T1/DDS For additional support related to the WPIM-T1/
Summary of the content on the page No. 20
Chapter 2: Setup and Installation 2.1.2 Pre-Installation To prepare the host platform for the WPIM-T1/DDS, proceed as follows: 1. Turn off and disconnect the host platform from the power source. 2. Mark all network cables attached to the host platform for ease of re-installation. 3. Disconnect all network cables attached to the host platform. 4. Refer to detailed instructions contained in the host platform’s user guide to remove the chassis cover. This procedure must be completed before inst