Summary of the content on the page No. 1
TL-SG3210/TL-SG3216/TL-SG3424
JetStream L2 Managed Switch
Rev: 1.1.0
1910010729
Summary of the content on the page No. 2
COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks or registered trademarks of their respective holders. No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from TP-LINK TECHNOLOGIES CO., LTD. Copyright © 2013 TP-LINK TECHNOLOGIES CO.,
Summary of the content on the page No. 3
Safety Information When product has power button, the power button is one of the way to shut off the product; When there is no power button, the only way to completely shut off power is to disconnect the product or the power adapter from the power source. Don’t disassemble the product, or make repairs yourself. You run the risk of electric shock and voiding the limited warranty. If you need service, please contact us. Avoid water and wet locations. This product can be used in
Summary of the content on the page No. 4
CONTENTS Package Contents ..........................................................................................................................1 Chapter 1 About this Guide...........................................................................................................2 1.1 Intended Readers .........................................................................................................2 1.2 Conventions................................................................
Summary of the content on the page No. 5
4.4.2 SSL Config.......................................................................................................23 4.4.3 SSH Config ......................................................................................................24 Chapter 5 Switching....................................................................................................................30 5.1 Port.........................................................................................................
Summary of the content on the page No. 6
7.1 STP Config .................................................................................................................81 7.1.1 STP Config.......................................................................................................81 7.1.2 STP Summary..................................................................................................83 7.2 Port Config.............................................................................................................
Summary of the content on the page No. 7
9.3.1 Global Config .................................................................................................125 9.3.2 Port Config.....................................................................................................125 9.3.3 OUI Config .....................................................................................................127 Chapter 10 ACL....................................................................................................................
Summary of the content on the page No. 8
11.4.1 Global Config .................................................................................................166 11.4.2 Port Config.....................................................................................................168 11.4.3 Radius Server ................................................................................................169 Chapter 12 SNMP..................................................................................................................
Summary of the content on the page No. 9
14.2.3 Remote Log ...................................................................................................206 14.2.4 Backup Log....................................................................................................207 14.3 Device Diagnose.......................................................................................................208 14.3.1 Cable Test......................................................................................................208 14
Summary of the content on the page No. 10
Package Contents The following items should be found in your box: One JetStream L2 Managed Switch One power cord One console cable Two mounting brackets and other fittings Installation Guide Resource CD for TL-SG3210/TL-SG3216/TL-SG3424 switch, including: This User Guide Other Helpful Information Note: Make sure that the package contains the above items. If any of the listed items are damaged or missing, please contact your distributor. 1
Summary of the content on the page No. 11
Chapter 1 About this Guide This User Guide contains information for setup and management of TL-SG3210/TL-SG3216/ TL-SG3424 JetStream L2 Managed Switch. Please read this guide carefully before operation. 1.1 Intended Readers This Guide is intended for network managers familiar with IT concepts and network terminologies. 1.2 Conventions In this Guide the following conventions are used: The switch or device mentioned in this Guide stands for JetStream L2 Managed Switch without any expla
Summary of the content on the page No. 12
Chapter Introduction Chapter 4 System This module is used to configure system properties of the switch. Here mainly introduces: System Info: Configure the description, system time and network parameters of the switch. User Manage: Configure the user name and password for users to log on to the Web management page with a certain access level. System Tools: Manage the configuration file of the switch. Access Security: Provide different security measures for the login to enhance
Summary of the content on the page No. 13
Chapter Introduction Chapter 9 QoS This module is used to configure QoS function to provide different quality of service for various network applications and requirements. Here mainly introduces: DiffServ: Configure priorities, port priority, 802.1P priority and DSCP priority. Bandwidth Control: Configure rate limit feature to control the traffic rate on each port; configure storm control feature to filter broadcast, multicast and UL frame in the network. Voice VLAN: Configure v
Summary of the content on the page No. 14
Chapter Introduction Chapter 14 Maintenance This module is used to assemble the commonly used system tools to manage the switch. Here mainly introduces: System Monitor: Monitor the memory and CPU of the switch. Log: View configuration parameters on the switch. Device Diagnose: Test the connection status of the cable connected to the switch, test if the port of the switch and the connected device are available. Network Diagnose: Test if the destination is reachable and the acco
Summary of the content on the page No. 15
Chapter 2 Introduction Thanks for choosing the TL-SG3210/TL-SG3216/TL-SG3424 JetStream L2 Managed Switch! 2.1 Overview of the Switch Designed for workgroups and departments, TL-SG3210/TL-SG3216/TL-SG3424 from TP-LINK provides wire-speed performance and full set of layer 2 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a v
Summary of the content on the page No. 16
2.3 Appearance Description 2.3.1 Front Panel Figure 2-1 Front Panel The following parts are located on the front panel of the switch: 10/100/1000Mbps Ports: Designed to connect to the device with a bandwidth of 10Mbps, 100Mbps or 1000Mbps. Each has a corresponding 1000Mbps LED. SFP Ports: Designed to install the SFP module. TL-SG3216/TL-SG3424 switch features some SFP transceiver slots that are shared with the associated RJ45 ports. The associated two ports are referred to as “Co
Summary of the content on the page No. 17
2.3.2 Rear Panel The rear panel of the switch features a power socket and a Grounding Terminal (marked with ). Figure 2-2 Rear Panel Grounding Terminal: The switch already comes with Lightning Protection Mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. AC Power Socket: Connect the female connector of the power cord here, and the male connector to the AC power outlet. Please make sure the voltage of the power supply
Summary of the content on the page No. 18
Chapter 3 Login to the Switch 3.1 Login 1) To access the configuration utility, open a web-browser and type in the default address http://192.168.0.1 in the address field of the browser, then press the Enter key. Figure 3-1 Web-browser Tips: To log in to the switch, the IP address of your PC should be set in the same subnet addresses of the switch. The IP address is 192.168.0.x ("x" is any number from 2 to 254), Subnet Mask is 255.255.255.0. For the detailed instructions as to how
Summary of the content on the page No. 19
Figure 3-3 Main Setup-Menu Note: Clicking Apply can only make the new configurations effective before the switch is rebooted. If you want to keep the configurations effective even the switch is rebooted, please click Saving Config. You are suggested to click Saving Config before cutting off the power or rebooting the switch to avoid losing the new configurations. Return to CONTENTS 10
Summary of the content on the page No. 20
Chapter 4 System The System module is mainly for system configuration of the switch, including four submenus: System Info, User Manage, System Tools and Access Security. 4.1 System Info The System Info, mainly for basic properties configuration, can be implemented on System Summary, Device Description, System Time, Daylight Saving Time and System IP pages. 4.1.1 System Summary On this page you can view the port connection status and the system information. The port status diagram shows