Siemens Type Vector E50001-F710-A420-X-4A00 user manual

User manual for the device Siemens Type Vector E50001-F710-A420-X-4A00

Device: Siemens Type Vector E50001-F710-A420-X-4A00
Category: Switch
Manufacturer: Siemens
Size: 2.32 MB
Added : 9/3/2013
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Siemens Type Vector E50001-F710-A420-X-4A00. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Siemens Type Vector E50001-F710-A420-X-4A00.

For your convenience

If looking through the Siemens Type Vector E50001-F710-A420-X-4A00 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Siemens Type Vector E50001-F710-A420-X-4A00 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Siemens Type Vector E50001-F710-A420-X-4A00 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Siemens Type Vector E50001-F710-A420-X-4A00 User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Siemens Type Vector E50001-F710-A420-X-4A00 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Siemens Type Vector E50001-F710-A420-X-4A00. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Type Vector®
manual group-operated switch
instruction manual
Installation operation maintenance E50001-F710-A420-X-4A00
Answers for energy.

Summary of the content on the page No. 2

Arc flash hazard and hazardous voltages. Will cause death, serious injury or property damage. Always de-energize and ground the equipment before maintenance. Read and understand this instruction manual before using equipment. Maintenance should be performed only by qualified personnel. The use of unauthorized parts in the repair of the equipment or tampering by unqualified personnel will result in dangerous conditions which will cause death, severe injury or equipment damage. Follow all sa

Summary of the content on the page No. 3

Table of contents Introduction 4 - 5 Note: These instructions do not purport to cover all details or variations in equipment, nor to provide for every possible contingency General description 6 - 7 to be met in connection with installation, operation or maintenance. Should further information be desired or should particular Receiving, handling and storage 8 - 10 problems arise that are not covered sufficiently for the purchaser’s purposes, the matter should be referred to the local sale

Summary of the content on the page No. 4

Introduction Arc flash hazard and hazardous voltages. Will cause death, serious injury or property damage. Always de-energize and ground the equipment before maintenance. Read and understand this instruction manual before using equipment. Maintenance should be performed only by qualified personnel. The use of unauthorized parts in the repair of the equipment or tampering by unqualified personnel will result in dangerous conditions which will cause death, severe injury or equipment damage.

Summary of the content on the page No. 5

Introduction Signal words Field service operation and warranty issues The signal words "danger," "warning" and "caution" used in this instruction manual Siemens can provide competent, well indicate the degree of hazard that may be trained field service representatives to encountered by the user. These words are provide technical guidance and advisory defined as: assistance for the installation, overhaul, repair and maintenance of Siemens Danger - Indicates an imminently equipment, proce

Summary of the content on the page No. 6

General description Introduction Siemens type Vector® manual group- operated air switch is precision built equipment designed to function efficiently under normal operating conditions. It is designed and manufactured to operate within the parameters established in ANSI/ IEEE and NEMA standards for disconnecting and load-interrupter switches. Performance requirements of these standards have been met or exceeded by these designs. Specific standards which apply include: ANSI/IEEE C37.30

Summary of the content on the page No. 7

General description Scope Design Type These instructions cover the installation, operation and maintenance of a Siemens Manual group- type Vector® manual group-operated air Vector operated switch switch. The equipment designs described in this instruction manual consists of group-operated air switch for application Table 1: Type Vector manual group-operated air up to 38.0 kV. A typical type Vector manual switch group-operated air switch is shown in Figure 1. All diagrams, descriptions a

Summary of the content on the page No. 8

Receiving, handling and storage Receiving 3. Hardware box: Each type Vector® manual group-operated a) Pipe guide as sembly air switch is securely blocked and braced b ) Loc k segment assembly for shipment on a pallet. It is crated, boxed or covered as required by shipping Pipe guide assembly c ) Coupling assembly conditions. If special handling is required, d ) Handle assembly it is so indicated. The type Vector manual group-operated air switch must be han

Summary of the content on the page No. 9

Receiving, handling and storage 3. Any visible damage must be noted on 8. Obt ain the original of the carrier the delivery receipt and acknowledged inspection report and forward it along with the driver’s signature. The with a copy of the noted delivery damage should be detailed as much as receipt to Siemens at +1 (501) 362- possible. It is essential that a notation 8296. Approval must be obtained by "possible internal damage, subject to Siemens from the carrier before any inspection

Summary of the content on the page No. 10

Receiving, handling and storage Lifting and moving Lifting type Vector manual group- operated switch with crane There are a number of methods that can be used in handling the type Vector® Recommended lifting of type Vector manual group-operated switch that, when manual group-operated switch is by means properly employed, will not damage the of cable connected to an overhead crane type Vector manual group-operated or bucket truck. The cable is connected to switch. The handling method us

Summary of the content on the page No. 11

Installation Installation Installation instructions for the type Vector manual group-operated air switch are detailed in the following steps: A 1. Drill two mounting holes 11/16" in diameter located per the user's construction standards and spaced per Siemens assembly drawing. 2. Ins tall the mounting bolts in the holes. Mounting bolts to be furnished by Item Description others. A Single-point lift bracket 3. Using t he single-point lift bracket, lift the air switch approximately

Summary of the content on the page No. 12

Installation A A A A Item Description A Loosen bolt Figure 5: Loosen bolts 8. Remo ve single-point lift bracket. Note: Verify the piercing set screws are backed out all the way before sliding the 9. Gr ound the air switch unit (and surge handle assembly on the bottom shaft arresters if required) using #2 or larger section (refer to Figure 6: Before piercing). copper wire. A grounding point (1/2-13 tapped hole) is provided in the side of the mounting bracket (refer to assembly drawi

Summary of the content on the page No. 13

Operating handle adjustment procedure Operating handle adjustment procedure 3. T ighten the four clamp bolts. Do not tighten the piercing set screws yet. The next series of steps address adjusting Open and close the air switch slowly the position of the handle assembly and and then rapidly. Check for a smooth lock segment assembly so that the handle operation of the air switch. Adjust the can be inserted into the OPEN and CLOSED pipe guides for a smooth, non-binding slot correctly. o

Summary of the content on the page No. 14

Operational check out instructions Operational check out instructions b ) With the switch still fully closed and the interrupter cocked (set to trip), Operational check out instructions for the the lever should stick above the type Vector® manual group-operated C D nylon bumper at least 1/8" A B switch are detailed in the following steps: (3.2 mm). There should be no metal- C D 1. Switc hes are fully adjusted and to-metal contact between the inspected before they leave the in

Summary of the content on the page No. 15

Operational check out instructions 2. As the blade continues to rotate open, the interrupter lever must make full metal-to-metal contact with the contactor (refer to Figure 13: Contactor connection). At this point, the A A load then transfers from the auxiliary contacts to the interrupter's lever arm so that the interrupter now carries the full load. Item Description 3 . As t he blade continues to rotate Item Description open, the interrupter

Summary of the content on the page No. 16

Maintenance Maintenance Maintenance instructions for the type Vector® manual group-operated switch are detailed in the following steps: 1. Periodically operate the switch and check for actions described in Operational check out instructions on pages 14-15. Lubricate the jaw, auxiliary contacts and the end of the blade with Dow Corning® Molykote FS- 1292 white grease. 2. With the handle in the CLOSED position of the lock segment, verify that the switch is fully closed and there is

Summary of the content on the page No. 17

Maintenance Table 2: Remarks 17

Summary of the content on the page No. 18

Published by and copyright © 2011: Siemens AG Energy Sector Freyeslebenstrasse 1 91058 Erlangen, Germany Siemens Energy, Inc. 99 Bolton Sullivan Drive Heber Springs, AR 72543 For more information, contact +1 (800) 347-6659 +1 (501) 362-8296 Order No. E50001-F710-A420-X-4A00 Replaces No. VEC4100 10/2/08 Printed in USA All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. T


Alternative user manuals
# User manual Category Download
1 Siemens AC-21A User manual Switch 9
2 Siemens ASC77.2U User manual Switch 5
3 Siemens AC-3 User manual Switch 0
4 Siemens DataNET Hub (DNH) User manual Switch 1
5 Siemens ERTEC200 User manual Switch 6
6 Siemens KVM series 3-1621 User manual Switch 1
7 Siemens MICROMASTER 411 User manual Switch 40
8 Siemens S7 User manual Switch 13
9 Siemens Class 87 User manual Switch 0
10 Siemens ISGS SG8158-00 User manual Switch 17
11 Siemens SCALANCE X-100 User manual Switch 27
12 Siemens SCALANCE X-200 User manual Switch 267
13 Siemens SCALANCE X-200 User manual Switch 79
14 Siemens Electrical Lean User manual Switch 2
15 Siemens 480V User manual Switch 11
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4