Siemens X005 user manual

User manual for the device Siemens X005

Device: Siemens X005
Category: Switch
Manufacturer: Siemens
Size: 1.49 MB
Added : 9/3/2013
Number of pages: 64
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Siemens X005. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Siemens X005.

For your convenience

If looking through the Siemens X005 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Siemens X005 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Siemens X005 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Siemens X005 User manual - Online PDF
Advertisement
« Page 1 of 64 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Siemens X005 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Siemens X005. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



1

Vorwort

2
Einführung

3
Netztopologien


4
Produkteigenschaften
SIMATIC NET

Industrial Ethernet
5
Montage und Wartung
SCALANCE X005
Hinweise zur CE-
6
Kennzeichnung
Inbetriebnahmehandbuch

7
Literaturverzeichnis

8
Maßzeichnung
10/2005
A2B00051528A Deutsch/English
Erzeugnisstand 01

Summary of the content on the page No. 2

Sicherheitstechnische Hinweise Dieses Handbuch enthält Hinweise, die Sie zu Ihrer persönlichen Sicherheit sowie zur Vermeidung von Sachschäden beachten müssen. Die Hinweise zu Ihrer persönlichen Sicherheit sind durch ein Warndreieck hervorgehoben, Hinweise zu alleinigen Sachschäden stehen ohne Warndreieck. Je nach Gefährdungsstufe werden die Warnhinweise in abnehmender Reihenfolge wie folgt dargestellt. Gefahr bedeutet, dass Tod oder schwere Körperverletzung eintreten wird, wenn d

Summary of the content on the page No. 3

Inhaltsverzeichnis 1 Vorwort ................................................................................................................................................... 1-1 1.1 Vorwort....................................................................................................................................... 1-1 2 Einführung .............................................................................................................................................. 2-1 2.

Summary of the content on the page No. 4

Summary of the content on the page No. 5

1 Vorwort 1.1 Vorwort Zweck der Inbetriebnahmeanleitung Diese Inbetriebnahmeanleitung unterstützt Sie bei der Inbetriebnahme des unmanaged Industrial Ethernet Entry Level Switches SCALANCE X005. Gültigkeitsbereich dieser Inbetriebnahmeanleitung Diese Inbetriebnahmeanleitung ist für folgende Geräte gültig: SIMATIC NET SCALANCE X005 6GK5005-0BA00-1AA3 Weiterführende Dokumentation Im Handbuch „SIMATIC NET Industrial Ethernet Twisted Pair- und Fiber Optic Netze“ erhalten Sie zusätzlich

Summary of the content on the page No. 6

Summary of the content on the page No. 7

2 Einführung 2.1 Einführung Dieses Kapitel gibt Ihnen einen Überblick über die Funktion des unmanaged Industrial Ethernet Entry Level Switches SCALANCE X005 Was ist möglich ? Der Switch SCALANCE X005 ermöglicht den kostengünstigen Aufbau von kleinen Industrial Ethernet Linien- bzw. Sternstrukturen mit Switching Funktionalität. Die Geräte sind für den Einsatz im Schaltschrank ausgelegt. Hinweis Der Einsatz eines SCALANCE X005 Switches in einem redundanten Ring ist nicht möglich, da

Summary of the content on the page No. 8

Summary of the content on the page No. 9

3 Netztopologien 3.1 Netztopologien Die Switching Technologie ermöglicht den Aufbau ausgedehnter Netze mit mehreren Teilnehmern und vereinfacht die Netzerweiterung. Welche Netztopologien können realisiert werden ? Mit dem Gerät SCALANCE X005 können Linien- und Sterntopologien realisiert werden. Linientopologie Bild 3-1 Linientopologie mit SCALANCE X005 Industrial Ethernet SCALANCE X005 Inbetriebnahmehandbuch, A2B00051528A 3-1

Summary of the content on the page No. 10

Netztopologien 3.1 Netztopologien Sterntopologie Bild 3-2 Sterntopologie mit SCALANCE X005 Industrial Ethernet SCALANCE X005 3-2 Inbetriebnahmehandbuch, A2B00051528A

Summary of the content on the page No. 11

4 Produkteigenschaften 4.1 SCALANCE X005 Lieferumfang Was wird mit dem SCALANCE X005 ausgeliefert ? • Gerät SCALANCE X005 • 2-poliger steckbarer Klemmenblock • Inbetriebnahmehandbuch (dieses Dokument) 4.2 SCALANCE X005 Auspacken und Prüfen Auspacken, Prüfen 1. Überprüfen Sie das Paket auf Vollständigkeit 2. Überprüfen Sie die Einzelteile auf Transportschäden. Warnung Nehmen Sie nur unbeschädigte Teile in Betrieb! Warnung Wird das Gerät SCALANCE X005 bei Umgebungstemp

Summary of the content on the page No. 12

Produkteigenschaften 4.3 SCALANCE X005 Produkteigenschaften 4.3 SCALANCE X005 Produkteigenschaften Anschlussmöglichkeiten Der SCALANCE X005 verfügt über fünf RJ45 Buchsen für den Anschluss von Endgeräten oder weiterer Netzsegmente. Bild 4-1 SCALANCE X005 Industrial Ethernet SCALANCE X005 4-2 Inbetriebnahmehandbuch, A2B00051528A

Summary of the content on the page No. 13

Produkteigenschaften 4.4 SCALANCE X005 TP-Schnittstellen 4.4 SCALANCE X005 TP-Schnittstellen Steckerbelegung RJ45-Buchse Bild 4-2 Steckerbelegung RJ45 Pinnummer Belegung Pin 8 n. c. Pin 7 n. c. Pin 6 TD- Pin 5 n. c. Pin 4 n. c. Pin 3 TD+ Pin 2 RD- Pin 1 RD+ Beim SCALANCE X005 sind die Twisted Pair-Schnittstellen, als RJ45-Buchse mit MDI-X Belegung (Medium Dependent Interface–Autocrossover) einer Netzkomponente ausgeführt. Achtung An dem TP-Port in RJ45 Aus

Summary of the content on the page No. 14

Produkteigenschaften 4.4 SCALANCE X005 TP-Schnittstellen dass ein automatisches Konfigurieren unterschiedlicher Geräte möglich ist. Das Autonegotiation-Verfahren ermöglicht es zwei Komponenten, die an einem Link-Segment angeschlossen sind, untereinander Parameter auszutauschen und sich mit Hilfe dieser Parameter auf die jeweils unterstützten Eckwerte der Kommunikation einzustellen. Hinweis Geräte, die kein Autonegotation unterstützen müssen auf 100 MBit / Halbduplex bzw. 10 MBit / Ha

Summary of the content on the page No. 15

Produkteigenschaften 4.5 SCALANCE X005 Spannungsversorgung 4.5 SCALANCE X005 Spannungsversorgung Spannungsversorgung Der Anschluss der Spannungsversorgung erfolgt über einen 2-poligen steckbaren Klemmenblock. Die Spannungsversorgung ist hochohmig mit dem Gehäuse verbunden, um einen erdfreien Aufbau zu ermöglichen. Die Spannungsversorgung ist potentialgebunden. Bild 4-3 Spannungsversorgung Bild 4-4 Steckerbelegung Pinnummer Belegung Pin 1 M (Masse) Pin 2 L+ (+18 - 32V DC) Warnu

Summary of the content on the page No. 16

Produkteigenschaften 4.7 SCALANCE X005 Technische Daten Portzustandsanzeige (grün/gelbe LEDs) Der Zustand der Schnittstellen wird über fünf LEDs signalisiert: Zustand Bedeutung Port 1 bis 5 LED leuchtet grün TP-Link vorhanden, kein Datenempfang Port 1 bis 5 LED leuchtet gelb TP-Link vorhanden, Daten empfangen am TP Port Port 1 bis 5 LED blinkt gelb Testphase, während Power on 4.7 SCALANCE X005 Technische Daten Technische Daten des SCALANCE X005 Anschlüsse Anschluss von Endgerät

Summary of the content on the page No. 17

Produkteigenschaften 4.7 SCALANCE X005 Technische Daten Zulässige Umgebungsbedingungen / EMV Betriebstemperatur 0°C bis +65°C Lager-/Transporttemperatur -40°C bis +80°C Relative Feuchte im Betrieb ‹ 95% (nicht kondensierend) Betriebshöhe 2000 m bei max 46 °C Umbebungstemperatur 3000 m bei max. 40 °C Umgebungstemperatur Funkstörgrad EN 61000-6-2 Class A (ersetzt EN 50081-2 Class A) EN 61000-6-2 Class B mit Klappferrit auf den Leitungen Hersteller: Würth Elektronik - Typ: 742 711 3

Summary of the content on the page No. 18

Produkteigenschaften 4.7 SCALANCE X005 Technische Daten Hinweis Die Anzahl der angeschlossenen Industrial Ethernet Switches SCALANCE X beeinflusst die Telegrammdurchlaufzeit. Beim Durchlauf eines Telegramms durch den SCALANCE X005 wird dieses durch die Store&Forward Funktion des Switch verzögert - bei 64 Byte Telegrammlänge um circa 10 µs (bei 100 Mbit/s) - bei 1500 Byte Telegrammlänge um circa 130 µs (bei 100 Mbit/s) Das heißt, je mehr SCALANCE X005 durchlaufen werden, desto höher is

Summary of the content on the page No. 19

5 Montage und Wartung 5.1 Montage Montagearten Der SCALANCE X005 lässt mehrere Montagearten zu: • Montage auf 35 mm DIN Hutschiene • Montage auf einer SIMATIC S7-300 Profilschiene • Wandmontage Hinweis Beachten Sie bei Installation und Betrieb die Aufbaurichtlinien und Sicherheitshinweise, die in dieser Beschreibung sowie im Handbuch SIMATIC NET Industrial Ethernet Twisted Pair- und Fiber Optic-Netze /2/ beschrieben sind. Hinweis Schützen Sie das Gerät durch geeignete Absch

Summary of the content on the page No. 20

Montage und Wartung 5.2 Hutschienenmontage 5.2 Hutschienenmontage Montage Montieren Sie den SCALANCE X005 auf einer 35 mm Hutschiene nach DIN EN 50022. 1. Hängen Sie die obere Rastführung des Geräts in die Hutschiene ein und drücken Sie es nach unten gegen die Hutschiene bis zum Einrasten. 2. Montieren Sie die elektrischen Anschlussleitungen. Bild 5-1 SCALANCE X005 Montage auf einer DIN-Hutschiene (35 mm) Demontage Um den SCALANCE X005 von der Hutschiene abzunehmen: 1. Demontie


Alternative user manuals
# User manual Category Download
1 Siemens AC-21A User manual Switch 9
2 Siemens ASC77.2U User manual Switch 5
3 Siemens AC-3 User manual Switch 0
4 Siemens DataNET Hub (DNH) User manual Switch 1
5 Siemens ERTEC200 User manual Switch 6
6 Siemens KVM series 3-1621 User manual Switch 1
7 Siemens MICROMASTER 411 User manual Switch 40
8 Siemens S7 User manual Switch 13
9 Siemens Class 87 User manual Switch 0
10 Siemens ISGS SG8158-00 User manual Switch 17
11 Siemens SCALANCE X-100 User manual Switch 27
12 Siemens SCALANCE X-200 User manual Switch 267
13 Siemens SCALANCE X-200 User manual Switch 79
14 Siemens Electrical Lean User manual Switch 2
15 Siemens 480V User manual Switch 11
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4