Siemens X-400 user manual

User manual for the device Siemens X-400

Device: Siemens X-400
Category: Switch
Manufacturer: Siemens
Size: 1.89 MB
Added : 9/3/2013
Number of pages: 148
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Siemens X-400. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Siemens X-400.

For your convenience

If looking through the Siemens X-400 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Siemens X-400 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Siemens X-400 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Siemens X-400 User manual - Online PDF
Advertisement
« Page 1 of 148 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Siemens X-400 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Siemens X-400. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1




Preface, Contents
SIMATIC NET
Introduction to
Operating Instructions for
1
Industrial Ethernet Switches
SCALANCE X-400
Industrial Ethernet Switches
System Description of

2
SCALANCE X-400
Product Description of
3
SCALANCE X-400
Media Modules, Covers,
4
Dummy Cover
Extender Modules
5
Installation and
6
Commissioning
Technical Specifications
7
Approvals, Certificates
Glossary, Index

C79000-G8976-C186-03
Release 11/2005

Summary of the content on the page No. 2

Classification of Safety-Related Notices This document contains notices which you should observe to ensure your own per- sonal safety, as well as to protect the product and connected equipment. These no- tices are highlighted in the manual by a warning triangle and are marked as follows according to the level of danger: Danger ! indicates that death or severe personal injury will result if proper precautions are not taken. Warning ! indicates that death or severe personal inj

Summary of the content on the page No. 3

Trademarks ® ® ® SIMATIC , SIMATIC NET , SCALANCE and SIMATIC NET Networking for Indus- ® try are registered trademarks of Siemens AG. Third parties using for their own purposes any other names in this document which re- fer to trademarks might infringe upon the rights of the trademark owners. Safety Instructions Regarding your Product Before you use the product described here, read the safety instructions below thor- oughly. Notice When using a SCALANCE X-400 in the ring (HSR, High

Summary of the content on the page No. 4

Personnel Qualification Requirements Only qualified personnel should be allowed to install and work on this equipment. Qualified personnel as referred to in this manual or in the warning notes are defined as persons who are familiar with the installation, assembly, startup and operation of this product and who possess the relevant qualifications for their work, e.g.: ● Training in or authorization for connecting up, grounding or labeling circuits and devices or systems in accordance with

Summary of the content on the page No. 5

Correct Usage of Software Products Please note the following regarding the correct usage of software products: Caution This software may only be used for the applications described in the catalog or the technical description and only in connection with software products, devices, or com- ponents from other manufacturers which have been approved or recommended by Siemens. Before you use the supplied sample programs or programs you have written yourself, make certain that no injury to p

Summary of the content on the page No. 6

Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 6 C79000-G8976-C186-03

Summary of the content on the page No. 7

Preface Purpose of the Operating Instructions These operating instructions describe the functions of the SCALANCE X-400 product line of modular Industrial Ethernet switches and support you during instal- lation, commissioning and troubleshooting on site. You will find information on con- figuration in the separate SCALANCE X-400 Configuration Manual. Validity of the Operating Instructions These operating instructions are valid for the following products: ● Industrial Ethernet Switches SC

Summary of the content on the page No. 8

Preface Further Documentation For help on configuration and diagnostics using Web-based management, the CLI command line, or SNMP, refer to the following documentation: ● SCALANCE X-400 Configuration Manual C79000-G8976-C187-01 This documentation is available on the Internet at http://support.automation.siemens.com/WW/view/en/19625108 ● SIMATIC NET Twisted Pair and Fiber-Optic Networks C79000-G8976-C125-02 This documentation is available on the Internet at http://support.automatio

Summary of the content on the page No. 9

Contents 1 Introduction to Industrial Ethernet Switches ............................................................ 11 1.1 Basic Information............................................................................................... 11 1.2 Topologies ......................................................................................................... 13 1.2.1 Ring with Redundancy Manager ....................................................................... 13 1.2.2 Star Struct

Summary of the content on the page No. 10

Contents 6.2.1 Installing / Removing a Media Module .............................................................. 72 6.2.2 Fitting / Removing the Covers ........................................................................... 74 6.2.3 Fitting / Removing a Dummy Cover................................................................... 75 6.3 Installing / Removing Extender Modules ........................................................... 76 6.3.1 Installing / Removing the Twisted Pair Ex

Summary of the content on the page No. 11

Introduction to 1 Industrial Ethernet Switches 1.1 Basic Information Switching With switching technology, data packets are forwarded directly from the input port to the appropriate output port during data exchange based on the address informa- tion. Switches operate on a direct delivery basis. Essentially, switches have the following functions: ● Connection of Collision Domains / Subnets Since repeaters and star couplers (hubs) operate at the physical level, their use is restricted

Summary of the content on the page No. 12

Introduction to Industrial Ethernet Switches The Need for Industrial Ethernet Switches With over 80% of LANs based on Ethernet, this is the most commonly used tech- nology. The use of switches is particularly important: They allow extensive net- works with large numbers of nodes to be set up, increase the data throughput and simplify network expansion. The modular SCALANCE X-400 Industrial Ethernet switches from SIMATIC NET are designed for use in high-performance networks that will also me

Summary of the content on the page No. 13

Introduction to Industrial Ethernet Switches 1.2 Topologies 1.2.1 Ring with Redundancy Manager To increase the availability, optical or electrical line topologies of up to 50 switches (SCALANCE X-400, SCALANCE X-200, or OSM/ESM) can be closed with a SCALANCE X414-3E to form a ring. Functional Description With a SCALANCE X414-3E operating as a redundancy manager, the two ends are closed to form a ring with redundancy manager. The redundancy function is activated or deactivated by switche

Summary of the content on the page No. 14

Introduction to Industrial Ethernet Switches Electrical Ring A redundant electrical ring with redundancy manager can be set up without media modules since the basic device provides two RJ-45 jacks on slot 5 that allow con- nection of electrical (twisted pair) connections (10, 100, 1000 Mbps). The factory setting defines the two ports on slot 5 as ring ports. Optical Ring An optical ring with redundancy manager is only possible with media modules. Which slots or ports should be used, depen

Summary of the content on the page No. 15

Introduction to Industrial Ethernet Switches Configuration Example Sample configurations with SCALANCE X414-3E, SIMATIC S7-200/300/400, op- erator control and monitoring system, H system and PC as end devices. SCALANCE X-400 SCALANCE X-400 RM S7-200 1000 Mbit/s S7-300 10/100 SCALANCE Mbit/s X-400 S7-400 H-System H-System Figure 1-1 Gigabit ring with redundancy manager (RM) PC S7-400 S7-400 Switch S7-300 SCALANCE PC X-400 Fiber Optic S7-400 Switch SCALANCE X204-2 S7-300 PC PC S7-

Summary of the content on the page No. 16

Introduction to Industrial Ethernet Switches 1.2.2 Star Structure Functional Description Star structures can be implemented with the SCALANCE X414-3E. The cascading depth and total span of a network are limited only by the signal propagation times of the communication connections. Properties of a Star Structure Each SCALANCE X414-3E communicates over a TP or FO cable with a central switch with which all other switches are also connected within a star structure. Communication is possible

Summary of the content on the page No. 17

Introduction to Industrial Ethernet Switches Configuration Example Sample configurations electrical / optical with SCALANCE X-400, SCALANCE X-200, SIMATIC S7-300/400, SIMATIC ET 200 and operator panel as end devices. SCALANCE X414-3E SCALANCE SCALANCE SCALANCE SCALANCE X414-3E X208 X208 X208 S7-400 S7-300 ET 200S S7-300 S7-400 S7-300 ET 200S ET 200S ET 200S ET 200S ET 200S Figure 1-3 Star structure (Electrical) SCALANCE X-400 Fiber Optic SCALANCE SCALANCE SCALANCE SCALANCE X206-1 X20

Summary of the content on the page No. 18

Introduction to Industrial Ethernet Switches 1.2.3 Line Structure Functional Description Line structures can be implemented with the SCALANCE X414-3E. The cascading depth and total span of a network are limited only by the signal propagation times of the communication connections. Properties of the Line Structure Each SCALANCE X414-3E communicates over a TP or FO cable with a neighbor- ing switch. Communication is possible over the optical ports in slots 5, 6, or 7 or over the electrical

Summary of the content on the page No. 19

Introduction to Industrial Ethernet Switches 1.2.4 Redundant Linking of Network Segments The example of redundant linking of two network segments as shown here is pos- sible only when linking between X414 because the standby function of the X414 is required. SCALANCE X414-3E SCALANCE X414-3E RM 1000 S7-200 Mbit/s S7-300 10/100 SCALANCE Mbit/s X-414-3E S7-400 SCALANCE X-414-3E 1000 Mbit/s SCALANCE X-414-3E RM Figure 1-6 Redundant linking of two subnets In this case, network seg

Summary of the content on the page No. 20

Introduction to Industrial Ethernet Switches The two devices connected in the configuration exchange data frames with each other to synchronize their operating statuses (one device is master and the other slave). If there are no problems, only the link from the master to the other network segment is active. If this link fails (for example due to a link-down or a device fail- ure), the slave activates its link as long as the problem persists. Operating Instructions for SCALANCE X-400


Alternative user manuals
# User manual Category Download
1 Siemens AC-21A User manual Switch 9
2 Siemens ASC77.2U User manual Switch 5
3 Siemens AC-3 User manual Switch 0
4 Siemens DataNET Hub (DNH) User manual Switch 1
5 Siemens ERTEC200 User manual Switch 6
6 Siemens KVM series 3-1621 User manual Switch 1
7 Siemens MICROMASTER 411 User manual Switch 40
8 Siemens S7 User manual Switch 13
9 Siemens Class 87 User manual Switch 0
10 Siemens ISGS SG8158-00 User manual Switch 17
11 Siemens SCALANCE X-100 User manual Switch 27
12 Siemens SCALANCE X-200 User manual Switch 267
13 Siemens SCALANCE X-200 User manual Switch 79
14 Siemens Electrical Lean User manual Switch 2
15 Siemens 480V User manual Switch 11
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4