Summary of the content on the page No. 1
___________________
SCALANCE X-200
Preface
1
___________________
Safety notices
Network topologies / media
2
___________________
redundancy
SIMATIC NET
3
___________________
Product properties
Industrial Ethernet Switches
4
___________________
Installation
SCALANCE X-200
5
___________________
Connection
Operating Instructions
Configuration / diagnostics
__________________ 6_
using remote mechanisms
IRT technology with
7
___________________
SCALANCE
Summary of the content on the page No. 2
Legal information Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal inju
Summary of the content on the page No. 3
Preface Overview of the SCALANCE X product family The SCALANCE X-200 product family is part of the SCALANCE X product family. Below, you will find a brief overview of this product family. The SCALANCE X family comprises various product lines that complement each other and that are carefully tuned to specific automation tasks. SCALANCE X005 and XB000 line, entry level Unmanaged switch with five twisted-pair ports and optical diagnostics on the device for use in machine and system islan
Summary of the content on the page No. 4
Preface The only difference between the SCALANCE XF204IRT and the SCALANCE X-204IRT is the shape. SCALANCE X-200 IRT PRO managed In terms of functionality, the SCALANCE X200 IRT PRO switches are the same as the SCALANCE X-200 IRT managed switches listed above. The switch with degree of protection IP65/IP67 is designed for use outside a cabinet and has PROFINET-compliant connector technology (RJ-45 in compliance with IEC 61076-3-117 for X204 IRT PRO or SC RJ in compliance with IEC 617
Summary of the content on the page No. 5
Preface One particular advantage of the SCALANCE X-200IRT switches in PROFINET networks is the integrated ERTEC. This gives priority to PROFINET packets when forwarding. WARNING When used under hazardous conditions (zone 2), the devices of the SCALANCE X-100 and SCALANCE X-200 product lines must be installed in an enclosure. To comply with ATEX95 (EN 60079-15), this enclosure must meet the requirements of at least IP54 in compliance with EN 60529. WARNING – EXPLOSION HAZARD: DO
Summary of the content on the page No. 6
Preface SIMATIC NET SCALANCE X201-3P IRT PRO 6GK5201-3JR00-2BA6 SIMATIC NET SCALANCE X202-2P IRT 6GK5202-2BH00-2BA3 SIMATIC NET SCALANCE X201-3P IRT 6GK5201-3BH00-2BA3 SIMATIC NET SCALANCE X200-4P IRT 6GK5200-4AH00-2BA3 Names of the devices in these operating instructions The descriptions in these operating instructions always apply to the devices of the SCALANCE X-200 product line listed under "Validity of the Operating Instructions" in this document unless the description relates t
Summary of the content on the page No. 7
Table of contents Preface ...................................................................................................................................................... 3 1 Safety notices .......................................................................................................................................... 13 1.1 Important notes on using the device............................................................................................13 2 Network topologie
Summary of the content on the page No. 8
Table of contents 3.10.2 SCALANCE XF204-2 TP ports ................................................................................................... 55 3.10.3 SCALANCE XF204-2 FO ports................................................................................................... 57 3.11 SCALANCE X206-1 .................................................................................................................... 58 3.11.1 SCALANCE X206-1 product characteristics................
Summary of the content on the page No. 9
Table of contents 3.22.3 SCALANCE X201-3P IRT PRO FO interfaces ..........................................................................105 3.23 SCALANCE X202-2P IRT..........................................................................................................106 3.23.1 SCALANCE X202-2P IRT product characteristics.....................................................................106 3.23.2 SCALANCE X202-2P IRT TP ports ......................................................
Summary of the content on the page No. 10
Table of contents 6.1.3 Configuration with DHCP .......................................................................................................... 154 6.2 Updating the firmware with the boot loader .............................................................................. 155 6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI) .... 156 6.3.1 Principle of Web Based Management.......................................................................
Summary of the content on the page No. 11
Table of contents 8 PROFINET IO functionality.................................................................................................................... 245 8.1 Configuring with PROFINET IO .................................................................................................245 8.2 Settings in HW Config................................................................................................................249 8.2.1 Configuring alarms...........................
Summary of the content on the page No. 12
Table of contents SCALANCE X-200 12 Operating Instructions, 12/2011, A5E00349864-19
Summary of the content on the page No. 13
Safety notices 1 1.1 Important notes on using the device Safety notices on the use of the devices The following safety notices must be adhered to when setting up and operating the device and during all work relating to it such as installation, connecting up, replacing devices or opening the device. General notices WARNING Safety extra low voltage The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS). (This does not apply to
Summary of the content on the page No. 14
Safety notices 1.1 Important notes on using the device WARNING Replacing components EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2 OR ZONE 2. WARNING Requirements for the cabinet/enclosure When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure. WARNING WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLE
Summary of the content on the page No. 15
Safety notices 1.1 Important notes on using the device WARNING Suitable cables for temperatures in excess of 70 °C If the cable or conduit entry point exceeds 70 °C or the branching point of conductors exceeds 80 °C, special precautions must be taken. If the equipment is operated in an air ambient in excess of 50 °C to 70 °C, only use cables with admitted maximum operating temperature of at least 80 °C. WARNING Protection against transient voltage surges Provisions shall be mad
Summary of the content on the page No. 16
Safety notices 1.1 Important notes on using the device SCALANCE X-200 16 Operating Instructions, 12/2011, A5E00349864-19
Summary of the content on the page No. 17
Network topologies / media redundancy 2 2.1 Network topologies Switching technology allows extensive networks to be set up with numerous nodes and simplifies network expansion. Which topologies can be implemented? Bus, ring, or star topologies can be implemented with the X-200 IE switches. Note Make sure that the maximum permitted cable lengths for the relevant devices are not exceeded. You will find the permitted cable lengths in the technical specifications. For example, with t
Summary of the content on the page No. 18
Network topologies / media redundancy 2.1 Network topologies Star topology Figure 2-2 Electrical star topology. Example with SCALANCE X208 Figure 2-3 Star topology with X310 and X208 SCALANCE X-200 18 Operating Instructions, 12/2011, A5E00349864-19
Summary of the content on the page No. 19
Network topologies / media redundancy 2.1 Network topologies Ring topology Figure 2-4 Optical ring topology, example with SCALANCE X-200 and SCALANCE X-400 as redundancy manager SCALANCE X-200 Operating Instructions, 12/2011, A5E00349864-19 19
Summary of the content on the page No. 20
Network topologies / media redundancy 2.1 Network topologies
Figure 2-5 Electrical ring topology, example with SCALANCE X208 and SCALANCE X-400 as redundancy manager Figure 2-6 Ring topology with electrical and optical ring links, example with SCALANCE X206-1, SCALANCE X208, and SCALANCE X204-2 as redundancy