RuggedCom RS900 user manual

User manual for the device RuggedCom RS900

Device: RuggedCom RS900
Category: Switch
Manufacturer: RuggedCom
Size: 1.07 MB
Added : 12/5/2013
Number of pages: 42
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for RuggedCom RS900. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with RuggedCom RS900.

For your convenience

If looking through the RuggedCom RS900 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual RuggedCom RS900 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual RuggedCom RS900 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
RuggedCom RS900 User manual - Online PDF
Advertisement
« Page 1 of 42 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual RuggedCom RS900 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to RuggedCom RS900. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1





RS900 Series Family of Switches

Installation Guide
www.ruggedcom.com

Summary of the content on the page No. 2

Copyright This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced or translated to another language without the prior written consent of RuggedCom Inc. Disclaimer RuggedCom has checked the contents of this manual against the hardware and software described. However, deviations from the description cannot be completely ruled out. RuggedCom shall not be liable for any errors or omissions contained herein or

Summary of the content on the page No. 3

Table of Contents 1 Product Overview ................................................................................................................................................... 6 1.1 Functional Overview ................................................................................................................... 6 1.2 RuggedSwitch .............................................................................................................................. 7 1.3 RuggedWirel

Summary of the content on the page No. 4

RS900 Family Installation Guide 7.2 IEEE 1613 Type Tests ............................................................................................................... 42 7.3 IEC Environmental Type Tests.................................................................................................. 42 Page 4 of 42 © 2008 RuggedCom Inc. All rights reserved. Rev100

Summary of the content on the page No. 5

RS900 Family Installation Guide Table of Figures Figure 1 - Front Panel Description ........................................................................................................... 13 Figure 2 - Bottom Panel Description......................................................................................................... 14 Figure 3 - DIN Rail Mounting ................................................................................................................... 15 Figure

Summary of the content on the page No. 6

RS900 Family Installation Guide 1 Product Overview 1.1 Functional Overview The RS900 family of switches are environmentally hardened, fully managed switches supporting a variety of Ethernet interfaces including copper, fiber, wireless as well as Serial communications. The RS900 family’s superior ruggedized design coupled with the RuggedSwitch Operating System (ROS) provides improved system reliability and advanced networking features making it ideally suited for creating Ethernet netw

Summary of the content on the page No. 7

RS900 Family Installation Guide 1.2 RuggedSwitch RS900 9 Port Fiber Optic Ethernet Switch • Up to 9 fast Ethernet ports • Copper and fiber options Page 7 of 42 © 2008 RuggedCom Inc. All rights reserved. Rev100

Summary of the content on the page No. 8

RS900 Family Installation Guide 1.3 RuggedWireless Family of Products Wireless Port Characteristics • Configurable as an access, client, or bridge device • IEEE 802.11b/g Wireless Access Point with data rates up to 54 Mbps • WPA (Wi-Fi Protected Access) with TKIP for enhanced security and encryption • WPA2 / 802.11i with CCMP for robust security and encryption • IEEE 802.1X / RADIUS using EAP-PEAP for secure "enterprise class" authentication configuration • Pre-shared Key Mode (PS

Summary of the content on the page No. 9

RS900 Family Installation Guide RS920W RS930W Wireless Serial Device Server with 2 Serial Wireless Ethernet with Integrated 6-Port Ports and 1 Ethernet over VDSL Interface Switch and 1 Ethernet over VDSL Interface • 1 Wireless interface • 1 Wireless interface • 1 EoVDSL interface • 1 EoVDSL interface • 2 RS485/RS422/RS232 Serial ports • 6 fast Ethernet ports (DB9 or RJ45); Serial Fiber interface (ST) available Port 9 Antenna #1 Port 7 Ethernet over VDSL Ports 1 & 2 Serial

Summary of the content on the page No. 10

RS900 Family Installation Guide 1.4 RuggedVDSL Family of Products EoVDSL Port Characteristics • Symmetric data rates up to 35 Mbps with distances up to 2.5 km • Asymmetric data rates up to 40 Mbps with distances up to 5 km • Automatically selects fastest data rate based on distance and quality of cable • Manual speed configuration available RS900L RS910L Ethernet over VDSL with integrated 8-Port Ethernet over VDSL with 2 Serial and/or 2 Switch Ethernet Ports • 1 EoVDSL int

Summary of the content on the page No. 11

RS900 Family Installation Guide RS920L RS930L Dual Ethernet over VDSL interfaces with Dual Ethernet over VDSL interfaces with integrated Dual Port Serial Server Integrated 6-Port Switch • 2 EoVDSL interfaces • 2 EoVDSL interfaces • 2 RS485/RS422/RS232 Serial ports • 6 fast Ethernet ports (DB9 or RJ45); Serial Fiber interface (ST) available Port 9 Ethernet over VDSL Port 3 Ethernet over VDSL Ports 1 & 2 Serial Power & Alarm Page 11 of 42 © 2008 RuggedCom Inc. All r

Summary of the content on the page No. 12

RS900 Family Installation Guide 1.5 RuggedServer RS910 2-Port Serial Device Server with up to 3 Ethernet Ports • 2 RS485/RS422/RS232 Serial ports (DB9 or RJ45); Serial Fiber interface (ST) available • Up to 3 fast Ethernet ports • Copper and fiber options Page 12 of 42 © 2008 RuggedCom Inc. All rights reserved. Rev100

Summary of the content on the page No. 13

RS900 Family Installation Guide 1.6 Front Panel Description Power, Alarm Port 9 & Reset 10/100Base-TX or 100Base-Fx Ports 3 & 4 10/100Base-TX or 100Base-FX Ports 1-6 10/100Base-TX Figure 1 - Front Panel Description Status LED Colour Activity Comments Power LED Green Solid Power On Alarm LED Red Solid Alarm condition exists Table 1 - Status LEDs Page 13 of 42 © 2008 RuggedCom Inc. All rights reserved. Rev100

Summary of the content on the page No. 14

RS900 Family Installation Guide 1.7 Bottom Panel Description Console Port Chassis Ground Power Port Failsafe Relay Optional Din-Rail Mounting Bracket Figure 2 - Bottom Panel Description Page 14 of 42 © 2008 RuggedCom Inc. All rights reserved. Rev100

Summary of the content on the page No. 15

RS900 Family Installation Guide 2 Installation 2.1 Din Rail Mounting An optional DIN rail-mounting bracket is available for the unit. The figure below details mounting instructions for the standard 1” DIN Rail. Figure 3 - DIN Rail Mounting Page 15 of 42 © 2008 RuggedCom Inc. All rights reserved. Rev100

Summary of the content on the page No. 16

RS900 Family Installation Guide 2.2 Power Supply Wiring and Grounding 2.2.1 AC Power Supply Wiring and Grounding AC Surge Chassis Line/Hot Ground Ground AC Neutral Figure 4 - Power Supply Inputs The AC power supply inputs should be connected as follows: 1. +/L should be connected to AC Line/Hot. 2. -/N should be connected to AC Neutral. 3. Surge Ground should be connected to the Chassis Ground via a braided cable or other appropriate grounding wire. Surge Ground is used as the

Summary of the content on the page No. 17

RS900 Family Installation Guide 2.2.2 DC Power Supply Wiring and Grounding Figure 5 - DC Power supply wiring and grounding diagram The low voltage DC power supply features reverse polarity protection and dual independent inputs. The latter feature allows the connection of two DC sources with the same nominal voltage to provide redundant power supply inputs. The DC power supply inputs should be connected as follows: 1. Connect to the DC inputs according to the polarity markings

Summary of the content on the page No. 18

RS900 Family Installation Guide 2.2.3 Failsafe Output Wiring The Failsafe output relay is provided to signal critical error conditions that may occur on the unit. The contacts are energized upon power up of the unit and remain energized until an alarm condition or power loss occurs. Figure 6 - Failsafe Output Relay Page 18 of 42 © 2008 RuggedCom Inc. All rights reserved. Rev100

Summary of the content on the page No. 19

RS900 Family Installation Guide 2.2.4 Dielectric Strength Testing Units which are to have dielectric strength testing (HIPOT testing) done in the field must have the braided ground cable disconnected during the test. This is required in order to prevent the surge suppression circuitry, which is connected to surge ground, from being activated. Figure 7 - Dielectric Strength Testing Page 19 of 42 © 2008 RuggedCom Inc. All rights reserved. Rev100

Summary of the content on the page No. 20

RS900 Family Installation Guide 2.3 RS232 Console Port Wiring The RS232 port is used for configuring the unit. A straight-through serial cable with a DB-9 connector is required. There is no need to crossover the Transmit and Receive signals from the PC side since this has been done internally. Figure 8 - RS232 Female DCE pin-out Pin Signal 1 No Connection 2 Transmit Data 3 Receive Data 4 No Connection 5 Ground 6 No Connection 7 No Connection 8 No Connection 9 No Connect


Alternative user manuals
# User manual Category Download
1 RuggedCom M2200 User manual Switch 3
2 RuggedCom RS940G User manual Switch 9
3 RuggedCom RS900 User manual Switch 382
4 RuggedCom RSG2100 User manual Switch 567
5 RuggedCom RS900GP User manual Switch 7
6 RuggedCom RS900G User manual Switch 59
7 RuggedCom RSG2200 User manual Switch 13
8 RuggedCom RS1600 User manual Switch 28
9 RuggedCom RS8000 User manual Switch 41
10 RuggedCom RUGGED VDSL RS910L User manual Switch 1
11 RuggedCom RSG2288 User manual Switch 22
12 RuggedCom RSG2300 User manual Switch 130
13 RuggedCom I800 User manual Switch 13
14 RuggedCom m2200 User manual Switch 0
15 RuggedCom RSG2100P User manual Switch 6
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4