RTS KGATX0101400 user manual

User manual for the device RTS KGATX0101400

Device: RTS KGATX0101400
Category: Switch
Manufacturer: RTS
Size: 0.7 MB
Added : 12/5/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for RTS KGATX0101400. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with RTS KGATX0101400.

For your convenience

If looking through the RTS KGATX0101400 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual RTS KGATX0101400 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual RTS KGATX0101400 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
RTS KGATX0101400 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual RTS KGATX0101400 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to RTS KGATX0101400. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

RTS Automatic Transfer Switch
400A, 120/240V, Single-phase
Model No.: KGATX0101400
TECHNICAL
MANUAL
A new standard of reliability
This manual should remain with the unit.

Summary of the content on the page No. 2

Important Safety Instructions Read the following information carefully before attempting to install, operate or service this equipment. Also read the instructions and information on tags, decals, and labels that may   be affixed to the transfer switch. Replace any decal or label that is no longer legible. DANGER! Connection of a generator to an electrical system normally supplied by an electric utility shall be by means of suitable transfer equipment so as to isolate the electric sys

Summary of the content on the page No. 3

Table of Contents � Because jewelry conducts electricity, wearing it Safety Rules .........................................Inside Front Cover may cause dangerous electrical shock. Remove Section 1 — General Information ...................................2 all jewelry (such as rings, watches, bracelets, etc.) before working on this equipment. 1.1 Introduction.............................................................2 � If work must be done on this equipment while 1.2 Equipment Description .

Summary of the content on the page No. 4

Section 1 — General Information RTS “W” Type Transfer Switch 1.1 INTRODUCTION 1.3 TRANSFER SWITCH DATA LABEL This manual has been prepared especially for the A DATA LABEL is permanently affixed to the transfer purpose of familiarizing personnel with the design, switch enclosure. Use this transfer switch only with application, installation, operation and servicing of the specific limits shown on the DATA LABEL and the applicable equipment. Read the manual carefully on other decals and labels

Summary of the content on the page No. 5

Section 2 — Installation RTS “W” Type Transfer Switch 2.4.1 2-POLE MECHANISM 2.1 INTRODUCTION TO INSTALLATION This equipment has been wired and tested at the These switches (Figure 2.1) are used with a single factory. Installing the switch includes the following phase system, when the single phase NEUTRAL line procedures: is to be connected to a Neutral Lug and is not to be switched. � Mounting the enclosure. � Connecting utility and generator power source Figure 2.1 — Typical 2-Pole Tr

Summary of the content on the page No. 6

Section 3 — Operation RTS “W” Type Transfer Switch NOTE: Auxiliary Contacts are rated 10 amps at 125 or 250 volts AC. DO NOT EXCEED THE RATED Use a torque wrench to tighten the conductors,  VOLTAGE AND CURRENT OF THE CONTACTS. being sure not to overtighten, or damage to the switch base could occur. If undertightened, a loose connection would result, causing excess Figure 2.3 – Auxiliary Contacts heat which could damage the switch base. Connect power source load conductors to clearly ma

Summary of the content on the page No. 7

Section 3 — Operation RTS “W” Type Transfer Switch � Window “A” OFF, Window “B” ON - LOAD termi- 3.2 MANUAL OPERATION nals (T1, T2, T3) are connected to emergency terminals (E1, E2, E3). DANGER Do NOT manually transfer under load.  Disconnect transfer switch from all power sourc- Do not use excessive force when operating the es by approved means, such as a main circuit  transfer switch manually or the manual handle breaker(s). could be damaged. A manual HANDLE is shipped with the tra

Summary of the content on the page No. 8

Section 3 — Operation RTS “W” Type Transfer Switch 3.2.2 CLOSE TO EMERGENCY SOURCE SIDE 3.3.2 GENERATOR VOLTAGE CHECKS Before proceeding, verify the position of the switch 1. On the generator panel, set the AUTO/OFF/ by observing window “B” in Figure 3.1. If window MANUAL switch to MANUAL position. The gen- “B” reads “ON”, the contacts are closed in the erator should crank and start. EMERGENCY (STANDBY) position. No further action 2. Let the generator stabilize and warm up at no- is req

Summary of the content on the page No. 9

Section 3 — Operation RTS “W” Type Transfer Switch 5. When checkout under load is complete, set main 3.4 GENERATOR TESTS UNDER LOAD circuit breaker of the generator to the OFF or 1. Set the generator's main circuit breaker to its OPEN position. OFF or OPEN position. 6. Let the generator run at no-load for several min- 2. Manually actuate the transfer switch main con- utes. Then, shut down by setting the AUTO/OFF/ tacts to their EMERGENCY (STANDBY) position. MANUAL switch to its OFF positio

Summary of the content on the page No. 10

Section 4 — Installation Diagram RTS “W” Type Transfer Switch Installation Diagram – Drawing No. 0F6401 8 487mm[19.2"] 61.3mm[2.4"] MOUNTING HOLES: Ø6.35mm[Ø0.25"] 4-PLACES 917mm[36.1"] 794mm[31.3"] 60.8mm[2.4"] 609.6mm[24.0"] 254mm[10.0"] TRIPLE EKO SUITABLE FOR 1", 1.25" & 1.50" CONDUIT 3 PLACES

Summary of the content on the page No. 11

Section 5 — Electrical Data RTS “W” Type Transfer Switch Interconnection Diagram - Drawing No. 0G1944 9

Summary of the content on the page No. 12

Section 5 — Electrical Data RTS “W” Type Transfer Switch Wiring Diagram/Schematic – Drawing No. 0D3819-A TR F1 1 N1 126 N1A N1A 7 F2 N2 N2A N2A 126 N1A A1 B1 T1 T2 205 LS1 2 3 5 6 LS3 6 RED TR 9 N2A WHITE C 1 4 E1 LS2 GTS A2 B2 E1 E2 N2A 23 23 B LEGEND TR C - CONTACTOR ACTUATING COIL A GTS - TRANSFER SWITCH CONTACTOR 194 194 TR - RELAY, TRANSFER TS - TERMINAL STRIP (CUSTOMER CONNECTION) LS1,LS2,LS3 - LIMIT SWITCHES, ACTUATOR F1,F2 - FUSE 5A SENSING NOTES: ALL CONTACTS SHOWN WITH TRANSFER SWI

Summary of the content on the page No. 13

Section 5 — Electrical Data RTS “W” Type Transfer Switch Wiring Diagram/Schematic – Drawing No. 0D3819-A N2A N2A N1A N1A N1 N2 GTS N1A E1 E2 N2A T1 T2 E2 N2A 205 N2A E1 126 N1A N1A 126 TR 205 A 7 1 B 9 3 N2A 194 N1A 23 205 E1 E1 23 194 N1A N2A N1A N1A N2A 23 194 F1 F2 N1 23 N2 194 TS 11 A1 A2 B1 B2 T1 UTILITY 1 T2 UTILITY 2 23 194

Summary of the content on the page No. 14

Section 6 — Exploded Views and Parts List RTS “W” Type Transfer Switch 400 A Switch Assembly – Drawing No. 0G1510$ 12

Summary of the content on the page No. 15

Section 6 — Exploded Views and Parts List RTS “W” Type Transfer Switch 400 A Switch Assembly – Drawing No. 0G1510$ ITEM PART NO. QTY. DESCRIPTION 1 0D7294 1 XFER SW-W 400A600V2P 2 0A7822 6 LUG, SLDLSS 600/250-1/0X1/4-28 3 026902 5 SCREW TAPTITE #8-32X1/4 BP 4 0C7907J 2 COVER LUG 2P 400AMP 5 024526 1 SCREW HHTT 5/16-18 X 3/4 CZ 6 057329 1 LUG, SOLDERLESS 350-#6X13/32 AL/CU 7 027482 1 WASHER SHAKEPROOF EXT 5/16 STEEL 8 022097 9 WASHER LOCK M6-1/4 9 0C8275 4 SCREW PPHM DSEMS M4-.7 X 10 ZN

Summary of the content on the page No. 16

Section 8 — Warranty RTS “W” Type Transfer Switch CARRIER WARRANTY/SERVICE Carrier will warrant that from the date of purchase, our transfer switch will be free from defects in material and workmanship for the items and periods set forth in the warranty statement found in the owners manual of the Carrier generator that this transfer switch will be utilized with. Any equipment that the purchaser/owner claims to be defective must be examined by the nearest Carrier Dealer. THIS WARRANTY IS IN P


Alternative user manuals
# User manual Category Download
1 Sony 4-296-436-11 (2) User manual Switch 0
2 3Com 10/100BASE-TX User manual Switch 61
3 3Com 2226-SFP User manual Switch 688
4 3Com 16985ua.bk User manual Switch 10
5 3Com 10BASE-T User manual Switch 4
6 3Com 10BASE-2 User manual Switch 1
7 3Com 1000BASE User manual Switch 6
8 3Com 2226 PLUS User manual Switch 473
9 3Com 2250-SFP User manual Switch 538
10 3Com 1600 User manual Switch 0
11 3Com 2924-PWR User manual Switch 72
12 Sony BZPS-8001 User manual Switch 1
13 Sony DFS-700P User manual Switch 123
14 Sony DVS-9000 User manual Switch 9
15 Sony DVS-9000SF User manual Switch 5