Q-Logic QLogic9080 user manual

User manual for the device Q-Logic QLogic9080

Device: Q-Logic QLogic9080
Category: Switch
Manufacturer: Q-Logic
Size: 0.48 MB
Added : 9/21/2013
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Q-Logic QLogic9080. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Q-Logic QLogic9080.

For your convenience

If looking through the Q-Logic QLogic9080 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Q-Logic QLogic9080 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Q-Logic QLogic9080 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Q-Logic QLogic9080 User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Q-Logic QLogic9080 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Q-Logic QLogic9080. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

[ Quick Start Guide ]
SilverStorm™ 9080 INSTALLATION d
QUICK START GUIDE

Summary of the content on the page No. 2

Purchasers of OEM products should consult with the OEM for support. Support Headquarters QLogic Corporation 4601 Dean Lakes Blvd Shakopee, MN 55379 QLogic Web Site www.qlogic.com Technical Support Web Site support.qlogic.com Technical Support Email support@qlogic.com Technical Training Email tech.training@qlogic.com North American Region Email support@qlogic.com Phone +1 952-932-4040 Fax +1 952-932-4018 All other regions of the world QLogic Web Site www.qlogic.com

Summary of the content on the page No. 3

SilverStorm 9080 Quick Start Guide Pre-Installation Checklist Before beginning the actual installation, the Site Implementation Engineer must perform the following tasks: Step 1. Check the packing list to verify all ordered equipment has been received. The box should contain: ❑ A SilverStorm 9080 switch with the following pre-installed: ❑ Four (4) fan units ❑ Power supplies and blanks (6 total). ❑ InfiniBand (IB) leaf modules (up to 8 total) ❑ Spine modules and blanks (2 total) ❑ Virtual I/O ha

Summary of the content on the page No. 4

Step 4. Verify that the equipment shipped matches the packing list. Tools and Equipment Required ❑ An ESD wrist strap ❑ A #2 Phillips screwdriver ❑ Pen (felt-tip) to mark the mounting holes on the rack 2

Summary of the content on the page No. 5

Installation Tasks NOTE: Before performing the installation tasks, take a few minutes to review the figures below. It is important to understand the slot numbering for the leaf modules and spine modules (and the corresponding spine RJ-45 ports). It is also important to understand the slot numbering for the fans and power supplies (and the corresponding AC power inlets for the power supplies). Figure 1. SilverStorm 9080 Chassis Front View Figure 2. SilverStorm 9080 Chassis Back View Leaf 7 Leaf

Summary of the content on the page No. 6

To perform the actual switch installation, the site implementation engineer must perform the following tasks, which are detailed in this section. Step 1. Check the installation site to verify the installation of cabinet power feeds, rails, and grounding. Step 2. Inspect the packaging and equipment for any shipping damage. Any shipping damage should be reported to the shipping company. Only unpack the the equipment if there is no shipping damage. Step 3. Record the equipment serial numbers. Step

Summary of the content on the page No. 7

❑ Flow control = XON/XOFF Step 2. Power up the switch. Step 3. To change the switch default IP address enter: setChassisIpAddr -h ipaddress -m netMask where -h ipaddress is the new IP address in dotted decimal (i.e., xxx.xxx.xxx.xxx) format, and -m netMask is the new subnet mask in dotted decimal (i.e., xxx.xxx.xxx.xxx) format. Step 4. To change the switch default gateway IP address enter: setDefaultRoute -h ipaddress where -h ipaddress is the new default gateway IP address in dotted decimal (

Summary of the content on the page No. 8

where -h ipaddress is the new IP address in dotted decimal (i.e., xxx.xxx.xxx.xxx) format, and -m netMask is the new subnet mask in dotted decimal (i.e., xxx.xxx.xxx.xxx) format. Step 7. To change the switch default gateway IP address enter: setDefaultRoute -h ipaddress where -h ipaddress is the new default gateway IP address in dotted decimal (i.e., xxx.xxx.xxx.xxx) format. Step 8. To to exit the CLI enter: logout Using the Chassis Viewer Step 1. Power up the switch. Step 2. Connect a Categor

Summary of the content on the page No. 9

Step 5. Type in the new switch IP address. Step 6. Type in the new net mask. Step 7. Click Apply. Step 8. To change the switch default gateway, from the main menu select OOB LAN IP then Set Default Gateway IP. The following screen is displayed: Figure 4. Set Default Gateway IP Window Step 9. Type in the correct switch default gateway IP address. Step 10. Click Apply. NOTE: A reboot is required to activate the new gateway IP address. Activating/Deactivating the Embedded Fabric Manager If the embe

Summary of the content on the page No. 10

Step 2. Check that the CD has been mounted. Type ls /mnt/cdrom. The system returns a list of files on the CD. Step 3. Create a subdirectory on the drive where the documentation will reside. Step 4. Type cp /mnt/cdrom/ / to copy the documentation to the subdirectory created in Step 3. Step 5. Navigate to the Documentation directory and open the desired PDF file. 8

Summary of the content on the page No. 11

Declaration of Conformity QLogic Corporation. 26650 Aliso Viejo Parkway Aliso Viejo, CA 92656 Phone: 949.389.6000 www.qlogic.com QLogic Corporation declares the following product is in compliance with the following standards. Product identification: Name: 96 Port InfiniBand Switch Model/Type: SilverStorm 9080 Standards applied: FCC Part 15, Subpart B, Class A; ICES-003; EMC; EN55022, Class A, EN61000-3-2 and EN61000-3-3; VCCI, Class A and EN55024 Test House: Test report is issued by: Name: Unde

Summary of the content on the page No. 12

10

Summary of the content on the page No. 13

© 2007 QLogic Corporation. QLogic, the QLogic logo, the Powered by QLogic logo, SANbox, SANsurfer, and SANsurfer Management Suite are registered trademarks or trademarks of QLogic Corporation. All other brands and product names are trademarks or registered trademarks of their respective owners. Information supplied by QLogic is believed to be accurate and reliable. QLogic Corporation assumes no responsibility for any errors in this brochure. QLogic Corporation reserves the right, without notice,

Summary of the content on the page No. 14

QLogic Corporation 26650 Aliso Viejo Parkway Aliso Viejo, CA 92656 949.389.6000 www.qlogic.com D000010-003 Rev. A J


Alternative user manuals
# User manual Category Download
1 Q-Logic QLogic16HA User manual Switch 0
2 Q-Logic QLogic2-8C User manual Switch 0
3 Q-Logic QLogic3000 User manual Switch 0
4 Q-Logic QLogic1403 User manual Switch 0
5 Q-Logic QLogic3810 User manual Switch 4
6 Q-Logic QLogic16-Feb User manual Switch 0
7 Q-Logic QLogic5000 User manual Switch 0
8 Q-Logic QLogic3800 User manual Switch 0
9 Q-Logic QLogic5000/9000 User manual Switch 0
10 Q-Logic QLogic1404 User manual Switch 0
11 Q-Logic QLogic50372-03 A User manual Switch 0
12 Q-Logic QLogic5000 SERIES User manual Switch 1
13 Q-Logic QLogic5200 User manual Switch 1
14 Q-Logic QLogic5202 User manual Switch 3
15 Q-Logic QLogic5602 User manual Switch 0
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4