Pelco MS508AFL user manual

User manual for the device Pelco MS508AFL

Device: Pelco MS508AFL
Category: Switch
Manufacturer: Pelco
Size: 0.23 MB
Added : 4/3/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Pelco MS508AFL. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Pelco MS508AFL.

For your convenience

If looking through the Pelco MS508AFL user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Pelco MS508AFL on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Pelco MS508AFL to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Pelco MS508AFL User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Pelco MS508AFL but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Pelco MS508AFL. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MS500 Series
Manual Switchers
Installation/
Operation Manual
C820M-D (1/01)
Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.pelco.com
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150
International Customers: Tel +1 (559) 292-1981 or FAX +1 (559) 348-1120

Summary of the content on the page No. 2

CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS ................................................................3 DESCRIPTION ...................................................................................................................4 MODELS ....................................................................................................................4 INSTALLATION ...............................................................................................................

Summary of the content on the page No. 3

IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture. 3. Only use replacement parts recommended by Pelco. 4. After replacem

Summary of the content on the page No. 4

DESCRIPTION The MS500 Series provides an inexpensive and reliable method of switching 4 to 18 inputs to a single monitor output using interlocked manual pushbuttons. Included in this series is the MS540 switcher with two monitor outputs and the capacity to switch up to 40 inputs with a 14 pushbutton panel. The MS500 Series Switchers are designed for either looping or terminating operation, depending on the model. MODELS Terminating MS504DT 4 inputs (UL) MS508DT 8 inputs (UL) MS512DT 12 inputs (U

Summary of the content on the page No. 5

INSTALLATION 1. Place the unit on a flat surface, or install it in an equipment rack using the appropriate NOTE: For the maximum rack-mount kit. recommended cable dis- tances refer to the installa- 2. Refer to Figures 1 - 6 and select the desired configuration for your installation. Make tion manuals supplied with all equipment connections as illustrated in the drawings. Refer to Table A for the type equipment (camera, lens of coaxial cable to use. and monitor) to be used with the switcher. 3.

Summary of the content on the page No. 6

LOOPING SWITCHERS IMPORTANT: Looping Use coaxial cable to connect the input and looping video cables to the appropriate input connectors. Connect the monitor(s) to the monitor output. (Refer to Figures 3 and 4.) switchers do not have inter- nal termination. Inputs must be terminated at 75 ohms by other equipment in the system. UN-TERMINATED TERMINATE MONITOR MONITOR (SWITCH IN THE (SWITCH IN THE 75Ω POSITION) HI-Z POSITION) CAMERA MON 4321 MS504LDT (REAR VIEW) AC INPUT CAMERA MON 4321 MS504DT (

Summary of the content on the page No. 7

SWITCHERS WITH AUDIO FOLLOW NOTE: Configuration does MS500 Series models with “AF” in the suffix have a connection for an audio signal source. Using appropriate cable with compatible connectors, connect audio signal sources to RCA not permit two-way commu- jack (refer to Figure 5). nication. Microphones or speakers, etc., can be in- stalled at the camera site. TERMINATE MONITOR (SWITCH IN THE 75Ω POSITION) AUDIO IN/OUT CAMERA AUDIO IN/OUT MON 4321 VIDEO OUT MS504AF (REAR VIEW) Figure 5. MS500

Summary of the content on the page No. 8

SWITCHERS WITH AMPLIFIED OUTPUT The MS540DT and MS540LDT switchers provide both an amplified output (Monitor 1) and a non-amplified output (Monitor 2). Most installations require the use of Monitor 2 output for proper operations. NOTE: Use Monitor 2 non-amplified output only when interfacing with the MPT9000CZ/MPT9000PZ or KBD9000/KBD9000-X Coaxitron controls. OPERATION To operate the MS500 Series Switcher, plug in the power cord and press a camera button to view video from the corresponding ca

Summary of the content on the page No. 9

AUDIO FOLLOW OPTION CON 3505 AUDIO AUDIO RCA OUTPUT INPUTS JAX 2 N 1 T1 18 V.A.C. 1 BLK BLK RED I1 I2 IN F1 BLK/YEL GRN AC 1/16 AMP GRN/YEL INPUT BLK/GRN YEL GRY RN R2 R2 75Ω 75Ω 75Ω BLK/RED BRN TYPICAL -FOR 220 VAC INPUT ADD JUMPER TO 2 & 3 2 CONNECTION N 1 REMOVE JUMPER FROM 1 & 3, 2 & 4 FOR VIDEO VIDEO LOOPING OUTPUT INPUTS DELETE TERMINATION RESISITORS 75 OHM FOR LOOPING Figure 7. Schematic for 4-18 Position Manual Switchers 75 TYP. 00-09 TYPICAL 10-19 CONNECTION FOR LOOPING 00 01 02* *30-3

Summary of the content on the page No. 10

SPECIFICATIONS VIDEO Inputs: 4, 8, 12, or 40 as indicated by the last two digits of the model number. Video Connectors: BNC Audio Connectors: AF Switchers 1/8-inch RCA phone jack BAF Switchers Terminal block Termination: Terminated or Non-looping Switchers Input 75-ohm internal termination Output 75-ohm source termination Looping Switchers Input High impedance looping Output High impedance looping ELECTRICAL (Models MS500G, MS500GL, MS540DT, and MS540LDT) Input Voltage: 120 VAC, 50/60 Hz or 230

Summary of the content on the page No. 11

GENERAL Switching: Interlocked manual pushbuttons Construction: Cover Steel, black polyester powder coat Chassis Steel, zinc plated Panel Aluminum, black polyester powder coat Environment: 32° to 120°F (0° to 48.89°C) Dimensions MS504 Series (except AFL, BAF, and BAF models): 1.75 (H) x 5.3 (W) x 9.3 (L) inches (4.45 cm x 13.46 cm x 23.62 cm) MS504AFL, MS504BAF, MS504BAFL, and MS508 Series (except AFL model): 1.75 (H) x 14.3 (W) x 9.3 (L) inches (4.45 cm x 36.32 cm x 23.62 cm) MS508AFL, MS512 Se

Summary of the content on the page No. 12

PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or workmanship for a period of one year after the date of shipment. (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information: Exceptions to this warranty are as noted below: 1. Model and serial number 2. Date of shipment, P.O. number


Alternative user manuals
# User manual Category Download
1 Pelco DX2000 User manual Switch 1
2 Pelco 100BASE-FX User manual Switch 2
3 Pelco C1510M-QS User manual Switch 0
4 Pelco C1501M User manual Switch 0
5 Pelco C1503M User manual Switch 0
6 Pelco C1906/PP User manual Switch 0
7 Pelco C1566M-C User manual Switch 0
8 Pelco C1528M-F User manual Switch 1
9 Pelco C1555M-F User manual Switch 1
10 Pelco C19125 User manual Switch 0
11 Pelco C1925 User manual Switch 0
12 Pelco 100BASE-TX User manual Switch 0
13 Pelco C1925/PP User manual Switch 0
14 Pelco C2403M-C User manual Switch 0
15 Pelco C2491M-B User manual Switch 0
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4