Pelco CM8500 user manual

User manual for the device Pelco CM8500

Device: Pelco CM8500
Category: Switch
Manufacturer: Pelco
Size: 2.73 MB
Added : 4/3/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Pelco CM8500. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Pelco CM8500.

For your convenience

If looking through the Pelco CM8500 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Pelco CM8500 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Pelco CM8500 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Pelco CM8500 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Pelco CM8500 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Pelco CM8500. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
Breakout Panels for
VA6000 Series Switcher
and CM8500 Matrix System
Installation/Operation
Manual C842M (9/96)
PELCO • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • (800) 289-9100 or (1-559) 292-1981
FAX (800) 289-9150 or (1-559) 292-3827

Summary of the content on the page No. 2

TABLE OF CONTENTS Section Page 1.0 WARNINGS ........................................................................................................................................1 2.0 SCOPE ...............................................................................................................................................2 3.0 DESCRIPTION ...................................................................................................................................2 4.0 INSTALLATI

Summary of the content on the page No. 3

INSTALLATION/OPERATION MANUAL BREAKOUT PANELS FOR VA6000 SERIES SWITCHER AND CM8500 MATRIX SYSTEM 1.0 WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and

Summary of the content on the page No. 4

2.0 SCOPE As was the case for the VA6000, all telescoped inputs for breakout panels used with the CM8500 are con- The information contained within this manual covers nected via the appropriate onboard header to existing the installation and operation of the Alarm Breakout “D” type connectors on the rear of the CM8500 Matrix Panels for the VA6000 Series Switcher and the Alarm, bay via ribbon cables. Wiretron and Relay Breakout Panels for the CM8500 Matrix system. The 24 inch (.609 m) and 120 inc

Summary of the content on the page No. 5

Figure 1. Alarm Breakout Panel Assembly Information–VA6000 Series Pelco Manual C842M (9/96) 3 ALARM BREAKOUT PANEL (PCB9000617) WIRING SCHEMATIC J1 J2 Mounting Plate CABLE ASSEMBLIES Keyed connectors 25-PIN Cable 15-PIN Cable PCB Layout

Summary of the content on the page No. 6

The table below lists the pin-out relationship between the alarm panel header, J2, and the 15-pin connec- tor on the rear of the VA6000 switcher for 8 input alarms. The pattern serves equally well for VA models with 4 input alarms: the first 4 Pin Numbers correspond to like numbered ALM numbers, with pins 5-10 unused and pins 11-15 serving the same functions as in the 8 input VA6000 Switcher model. Alarm Pin-outs 1-8/VA6000 J2 Header Pin-out on Alarm Breakout Rear Panel Connector

Summary of the content on the page No. 7

The table below lists the pin-out relationship between the alarm panel header, J1, and the 25-pin con- nector on the rear of the VA6000 switcher for 20 input alarms. The pattern serves equally well for VA models with 12 input alarms: the first 12 Pin Numbers correspond to like numbered ALM numbers with pins 13-20 unused and pins 21-25 serving the same functions as in the 20 input VA6000 Switcher models. Alarm Pin-outs 1-16/CM8500 Rear Panel-P4 J1 Header Pin-out on Alarm Breakout for CM8500 ALM

Summary of the content on the page No. 8

Figure 4. Alarm Breakout Panel Assembly Information–CM8500 Series 6 Pelco Manual C842M (9/96) WIRING SCHEMATIC PCB LAYOUT Mounting Plate CABLE ASSEMBLY ALARM BREAKOUT PANEL (PCB9000582)

Summary of the content on the page No. 9

The table below lists the pin-out relationship between the alarm panel header, J1, and P4 on the CM8500 for the first 16 alarms. The pattern serves equally well for alarms 17-32: P4 becomes P3 and the listed alarms go from 17-32 instead of 1-16. Alarm Pin-outs 1-16/CM8500 Rear Panel-P4 J1 Header Pin-out on Alarm Breakout for CM8500 ALM # Pin Number Pin Number Alarm Com 11 ... 1 ... 20 2 22 ... 3 ... 21 4 33 ... 5 ... 22 6 44 ...

Summary of the content on the page No. 10

Figure 6. Wiretron Breakout Panel Assembly Information–CM8500 Series 8 Pelco Manual C842M (9/96) WIRING SCHEMATIC Mounting Plate WIRETRON BREAKOUT PANEL RIBBON CABLE (PCB9000583)

Summary of the content on the page No. 11

The table below lists the pin-out relationship between the wiretron panel header, J1, and P5 on the CM8500 for the first 16 wire control positions. The pin mappings serve equally well for wire controls 17-32: P5 becomes P6 and the listed WIR numbers go from 17-32 instead of 1-16. J1 Header Pin-out on Wiretron Breakout Wire Control Pin-outs 1-16/CM8500 Panel for CM8500 Rear Panel-P5 WIR # Pin Number Pin Number 11 ... 1 ... 2 3 23 ... 5 ... 4 7 35 ... 9 ...

Summary of the content on the page No. 12

Figure 8. Wiretron Breakout Panel Assembly Information–CM8500 Series 10 Pelco Manual C842M (9/96) WIRING SCHEMATIC Mounting Plate RELAY BREAKOUT PANEL (PCB9000581) RIBBON CABLE ASSEMBLY PCB LAYOUT

Summary of the content on the page No. 13

Figure 9. Installation Configuration for the CM8500 Wiretron Breakout Panel Figure 10. Rack Panel Mounting Plate Dimensions Pelco Manual C842M (9/96) 11

Summary of the content on the page No. 14

The table below lists the pin-out relationship between the relay panel header, J1, and P1 on the CM8500 for the first 16 relay output positions. The pin mappings serve equally well for relay outputs 17-32: P1 becomes P2 and the listed RELAY numbers go from 17-32 instead of 1-16. Relay 1-16 Pin-outs CM8500 J1 Header Pin-out on Relay Rear Panel-P1 Breakout Panel for CM8500 RELAY # Pin Number Pin Number NC NO COM 1 ... ... 1 1 ... 2 ..

Summary of the content on the page No. 15

5.0 MODELS CM8500-WPNL-2 Wiretron breakout panel for up to 16 outputs/panel; 2-foot (.609 VA6008-APNL-2 VA6000 alarm breakout panel m) inter connecting ribbon cable for up to 8 alarm inputs; 2-foot supplied. (.609 m) interconnecting ribbon cable supplied. CM8500-WPNL-10 Same as CM8500-WPNL-2, ex- cept 10-foot (3.048 m) intercon- VA6008-APNL-10 Same as VA6008-APNL-2, ex- necting ribbon cable. cept 10-foot (3.048 m) intercon- necting ribbon cable. CM8500-RPNL-2 Relay breakout panel for up to 16 o

Summary of the content on the page No. 16

7.0 WARRANTY AND RETURN INFORMATION WARRANTY RETURNS Pelco will repair or replace, without charge, any merchandise proved In order to expedite parts returned to the factory for repair or credit, please defective in material or workmanship for a period of one year after the date call the factory at (800) 289-9100 or (559) 292-1981 to obtain an of shipment. authorization number (CA number if returned for credit, and RA number if returned for repair). Exceptions to this warranty are as noted below


Alternative user manuals
# User manual Category Download
1 Pelco DX2000 User manual Switch 1
2 Pelco 100BASE-FX User manual Switch 2
3 Pelco C1510M-QS User manual Switch 0
4 Pelco C1501M User manual Switch 0
5 Pelco C1503M User manual Switch 0
6 Pelco C1906/PP User manual Switch 0
7 Pelco C1566M-C User manual Switch 0
8 Pelco C1528M-F User manual Switch 1
9 Pelco C1555M-F User manual Switch 1
10 Pelco C19125 User manual Switch 0
11 Pelco C1925 User manual Switch 0
12 Pelco 100BASE-TX User manual Switch 0
13 Pelco C1925/PP User manual Switch 0
14 Pelco C2403M-C User manual Switch 0
15 Pelco C2491M-B User manual Switch 0
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4