Summary of the content on the page No. 1
ADDENDUM
Addendum No. C3409M
Date December 22, 2005
Manuals Affected C2462M-B, C2403M-C, C2410M-H,
C2491M-B, C2496M
Manual Update Switch Settings for Varifocal Lens
Manual Update The high resolution camera with vari-
focal lens and auto iris is configured at
the factory for automatic exposure.
SWITCH SETTINGS FOR VARIFOCAL LENS
The high resolution camera with varifocal lens and auto iris is configured at the factory for
automatic exposure.
1 AWB Automatic white balance
FACTORY SETTINGS
2 GA
Summary of the content on the page No. 2
INST ALLA TION ® 090 Series Camclosure Indoor Integrated Camera System ® C2462M-B (10/05)
Summary of the content on the page No. 3
CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS .................................................................................... 3 WELCOME ......................................................................................................................................... 4 REMOVE THE BUBBLE ....................................................................................................................... 5 INSTALL THE BACK BOX ................................................
Summary of the content on the page No. 4
IMPORTANT SAFEGUARDS AND WARNINGS 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and must not be installed where exposed to rain and moisture. 3. Use only installation methods and materials capable of supporting four times the maximum specified load. REGULATORY NOTICES This equipment has been tested and
Summary of the content on the page No. 5
WELCOME ® Thank you for purchasing Pelco’s Camclosure Integrated Camera System for indoor applications. The ICS090 Series system integrates a camera and lens package in a small, discreet dome. The system is easy to install and can be mounted to the surface of a ceiling/wall or recessed in a ceiling/wall. Prior to installation of your new system, thoroughly familiarize yourself with the information in this manual. The following is supplied with the 090 Series Camclosure Integrated Camera System:
Summary of the content on the page No. 6
REMOVE THE BUBBLE Turn the bubble counterclockwise and lift (refer to Figure 1). Place the bubble on a non-abrasive surface. If the unit is supplied with a liner, remove the liner before installing the unit. To remove the liner, gently lift it from the unit. Place the liner to the side; it will be reinstalled along with the bubble after the installation has been completed. Figure 1. How to Remove the Bubble C2462M-B (10/05) 5
Summary of the content on the page No. 7
INSTALL THE BACK BOX The installation methods for the ICS090 Series include the following: • Mount to the surface of a ceiling/wall • Install in a suspended ceiling • Install in a fixed ceiling/wall • Mount to the surface of a 4S standard electrical box • Install in a 4S deep electrical box Select the best method for your installation and refer to the following pages for instructions. 6 C2462M-B (10/05)
Summary of the content on the page No. 8
Installation to Surface of a Ceiling/Wall Refer to Figure 2 for the following steps. Refer to Figure 3 if installing the unit to a concrete ceiling/wall. 1. Pull video and power wires through the ceiling/wall. 2. Connect the video cable/wires. BNC – Connect the BNC connector from the Camclosure to a mating BNC connector. Twisted Pair – Blue wire = Video + Gray wire = Video - 3. Connect the power wires. Voltage Red Wire Black Wire 12 VDC + Ground 24 VAC ~~ AC Operation Only – If you are wiring mo
Summary of the content on the page No. 9
In-Ceiling Installation – Suspended Ceiling Refer to Figure 4 for the following steps. 1. Remove the ceiling tile from the ceiling. 2. Cut a four-inch diameter hole in the ceiling tile. 3. Remove the surface mount ring from the back box. Refer to Figure 5 and do the following: a. Place fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the back box. Do not discard surface mount ring, because it is requi
Summary of the content on the page No. 10
In-Ceiling Installation – Fixed Ceiling/Wall Refer to Figure 6 for the following steps. 1. Cut a four-inch diameter hole in the ceiling/wall. 2. Remove the surface mount ring from the back box. Refer to Figure 5 and do the following: a. Place fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the back box. 3. Connect the video cable/wires. BNC – Connect the BNC connector from the Camclosure to a mating
Summary of the content on the page No. 11
Installation to Surface of a 4S Standard Electrical Box Refer to Figure 7 for the following steps. 1. Attach the adapter ring to the 4S box with the two 8-32 x 1.00-inch screws (supplied). 2. Connect the video cable/wires. BNC – Connect the BNC connector from the Camclosure to a mating BNC connector. Twisted Pair – Blue wire = Video + Gray wire = Video - 3. Connect the power wires. Voltage Red Wire Black Wire 12 VDC + Ground 24 VAC ~~ AC Operation Only – If you are wiring more than one ICS090 Ca
Summary of the content on the page No. 12
Installation in a 4S Deep Electrical Box Refer to Figure 8 for the following steps. 1. Remove the surface mount ring from the back box. Refer to Figure 5 and do the following: a. Place fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the back box. 2. Attach the adapter ring to the 4S box with the two 8-32 x 1.00-inch screws (supplied). 3. Connect the video cable/wires. BNC – Connect the BNC connector
Summary of the content on the page No. 13
CAMERA POSITIONING Manually rotate and tilt the camera module to position the camera. Do not over-rotate the module. Excessively turning the module in one direction could result in damage to the wiring. Tilt 140° Pan 360° Rotation 360° Figure 9. How to Position Camera 12 C2462M-B (10/05)
Summary of the content on the page No. 14
CAMERA ADJUSTMENTS VARIFOCAL LENS ZOOM AND FOCUS ADJUSTMENTS 1. Select a field of view by turning the zoom adjustment ring clockwise/counterclockwise. Refer to Figure 10. 2. Tighten the zoom locking screw. 3. Adjust the focus by moving the focus locking screw clockwise/counterclockwise. 4. Tighten the focus locking screw. Figure 10. Location of Zoom and Focus Adjustments VARIFOCAL LENS AUTO IRIS LEVEL ADJUSTMENT To adjust the auto iris level do the following: 1. Manually rotate the camera modul
Summary of the content on the page No. 15
SWITCH SETTINGS Switch Settings for Fixed Focal Length Lens Without Auto Iris Refer to the switch drawing. The switch is located next to the lens. Automatic backlight compensa- tion (factory setting) is used under varying lighting conditions (such as outdoors) or fixed lighting conditions where there are no bright spots that darken other picture details. Manual backlight compensation is used in fixed lighting conditions to optimize the picture detail when there are bright spots. FACTORY SETTINGS
Summary of the content on the page No. 16
VERTICAL PHASE ADJUSTMENT (24 VAC OPERATION ONLY) When using more than one camera power supply, a brief vertical roll may occur on the monitor when a camera view is switched. To eliminate vertical roll reverse the 24 VAC connections on one camera. If both cameras are connected to the same transformer, this should solve the problem. If reversing the connections does not solve the problem, adjust the phase control by synchronizing, or line-locking, the cameras to one another. How to Adjust the Pha
Summary of the content on the page No. 17
REINSTALL THE DOME DOME LINER INSTALLATION If the unit is supplied with a dome liner, reinstall the liner before installing the bubble. To install the liner refer to Figure 13 and do the following: 1. Align the studs located on the camera module with the clips on the liner. 2. Lightly pinch the sides of the liner, opposite from the clips, and place clips over the studs. 3. Once the liner is secure, position the viewing window of the liner over the lens of the camera. 4. Install the bubble. Figur
Summary of the content on the page No. 18
SERVICE CONNECTOR An optional 4-foot service/monitor cable, part number ICS090-SC, is available for on-site setup and adjustments. To use the cable simply plug one end of the cable directly into the service connector of the ICS090 and connect the other end to any standard BNC (VIDEO IN) connector on a monitor. To assemble a longer service cable for the ICS090 Series Camclosure, purchase the following parts at a local electronics supply store: 1 2.5 mm monaural headphone plug 1 CPM 88 miniature c
Summary of the content on the page No. 19
SPECIFICATIONS BACKBOX Electrical Input Voltage: 12 VDC or 24 VAC (±10%), auto-sensing Power Consumption: 3 watts or less Video Connector: BNC General Pan/Tilt Adjustment Pan: 360° Tilt: 140° (20° to 160° range) Rotation: 360° Construction Back Box and Surface Mount Ring: ABS plastic Bubble: Polycarbonate Finish: White Environment: Indoor Operating Temperature: 32°F to 120°F (0° to 49°C) Weight Unit: .52 lb (.24 kg) Shipping: 2 lb (.91 kg) (Design and product specifications subject to change wit
Summary of the content on the page No. 20
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. ® • Three years on Genex Series products (multiplexers, server, and keyboard). ® • Three years on Camclosure and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X