Summary of the content on the page No. 1
®
3 4 4
CS 000/ 000/ 080 HZ
Power Amplifier Owner's Manual
For more information on other great Peavey products, visit your local Peavey dealer or go online to www.peavey.com
Summary of the content on the page No. 2
ENGLISH IMPORTANT SAFETY INSTRUCTIONS WARNING: When using electrical products, basic cautions should always be followed, including the following: 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with a dry cloth. 7. Do not block any of the ventilation openings. Install in accordance with manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat r
Summary of the content on the page No. 3
DEUTSCH WICHTIGE SICHERHEITSHINWEISE SICHERHEITSHINWEISEACHTUNG: Beim Einsatz von Elektrogeräten müssen u.a. grundlegende Vorsichtsmaßnahmen befolgt werden: 1. Lesen Sie sich diese Anweisungen durch. 2. Bewahren Sie diese Anweisungen auf. 3. Beachten Sie alle Warnungen. 4. Befolgen Sie alle Anweisungen. 5. Setzen Sie dieses Gerät nicht in der Nähe von Wasser ein. 6. Reinigen Sie es nur mit einem trockenen Tuch. 7. Blockieren Sie keine der Lüftungsöffnungen. Führen Sie die Installation gemäß den
Summary of the content on the page No. 4
FRENCH INSTRUCTIONS IMPORTANTES DE SECURITE ATTENTION: L’utilisation de tout appareil électrique doit être soumise aux precautions d’usage incluant: 1. Lire ces instructions. 2. Gardez ce manuel pour de futures références. 3. Prétez attention aux messages de précautions de ce manuel. 4. Suivez ces instructions. 5. N’utilisez pas cette unité proche de plans d’eau. 6. N’utilisez qu’un tissu sec pour le nettoyage de votre unité. 7. N’obstruez pas les systèmes de refroidissement de votre unité et
Summary of the content on the page No. 5
SPANISH INSTRUCCIONES IMPORTANTES PARA SU SEGURIDAD CUIDADO: Cuando use productos electrónicos, debe tomar precauciones básicas, incluyendo las siguientes: 1. Lea estas instrucciones. 2. Guarde estas instrucciones. 3. Haga caso de todos los consejos. 4. Siga todas las instrucciones. 5. No usar este aparato cerca del agua. 6. Limpiar solamente con una tela seca. 7. No bloquear ninguna de las salidas de ventilación. Instalar de acuerdo a las instrucciones del fabricante. 8. No instalar cerca de ni
Summary of the content on the page No. 6
JAPANESE 安全 の た め の 重要事項 警告: 電気製品を使用するときは、 次の項目を含め、 基本的な注意事項を常にお守りください。 1. 本書の指示内容をお読みください。 2. 本書は保管してください。 3. すべての警告に注意してください。 4. すべての指示に従ってください。 5. 本装置を水の近くで使用しないでください。 6. お手入れには乾いた布をお使いください。 7. 開口部をふさがないでください。 メーカーの指示に従って設置してください。 8. ラジエータ、 ストーブなど (アンプを含む)、 発熱体の近くに設置しないでください。 9. 分極プラグや接地プラグの安全性を損なわないようにしてください。 分極プラグの2つのブレードは、 一方が他より幅広くなっています。 接地式のプラグには2つのブレードと接地プラグがあります。 幅広のブレードや接地プラグは安全のために付けられています。 所定のプ ラグがコンセントなどに合わない場合、 旧式のコンセントなどの交換について技術者に問い合わせてください。 10. 電源コードを踏んだり挟んだりしないように保護してく
Summary of the content on the page No. 7
ENGLISH SPANISH FRENCH DEUTSCH JAPANESE Intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. CAUTION: Risk of electrical shock — DO NOT OPEN! CAUTION: To reduce the risk of electric shock, do not remove c
Summary of the content on the page No. 8
ENGLISH ® 3 4 4 CS 000/ 000/ 080 HZ Power Amplifiers Congratulations on your purchase of a Peavey CS Series power amplifier! Designed for years of reliable operation, CS Series amplifiers offer the sonic superiority and unsurpassed reliability for which Peavey is famous in a rugged, compact unit. Advanced technologies and extensive protection circuitry allow operation with greater efficiency, even under difficult loads ™ and power conditions. The DDT (Distortion Detection Technique) circuit
Summary of the content on the page No. 9
Summary of the content on the page No. 10
Wire Guage Charts Stranded Cable Lgth. Wire Gauge (AWG) Power Loss Power Loss Power Loss (ft.) (8 ohm load) (4 ohm load) (2 ohm load) 5 18 0.81% 1.61% 3.2% 16 0.51 1.02 2.0 14 0.32 0.64 1.28 12 0.20 0.40 0.80 10 0.128 0.25 0.51 10 18 1.61% 3.2% 6.2% 16 1.02 2.0 4.0 14 0.64 1.28 2.5 12 0.40 0.80 1.60 10 0.25 0.51 1.01 40 18 6.2% 11.9% 22% 16 4.0 7.7 14.6 14 2.5 5.0 9.6 12 1.60 3.2 6.2 10 1.01 2.0 4.0 8 0.60 1.20 2.4 18 11.9% 22% 37% 80 16 7.7 14.6 26 14 5.0 9.6 17.8 12 3.2 6.2 11.8 10 2.0 4.0 7.7
Summary of the content on the page No. 11
Operation Modes Stereo Operation For stereo (dual channel) operation, turn the amplifier OFF and set the mode select switches on the back panel to the out (extended) position. In this mode, both channels operate independently of each other, with their input attenuators controlling their respective levels. Thus, a signal at channel A’s input produces an amplified signal at channel A’s output, while a signal at channel B’s input produces an amplified signal at channel B’s output. Parallel Oper
Summary of the content on the page No. 12
CAUTION: The on/off switch in this unit does not break both sides of the primary mains. Hazardous energy can be present inside the chassis when the on/off switch is in the off position.
Summary of the content on the page No. 13
Front Panel 3 1 1 3 2 2 Indicators ® ™ CS Series amplifiers feature three front panel LED indicators per channel: PWR (power), SIG (signal) and DDT (Distortion Detection Technique). These LED indicators inform the user of each channel’s operating status and warn of possible abnormal conditions. PWR LED (1) The Power LED indicates that the channel is operational. It illuminates under normal operation and remains on even when the channel’s DDT circuit is activated. SIG LED (2) The Signal LED il
Summary of the content on the page No. 14
Protection Features ® The Peavey CS Series incorporates several circuits to protect the amplifier and speakers under virtually any situation. Peavey has made the amplifiers as foolproof as possible by making them immune to short and open circuits, mismatched loads, ™ DC voltage and overheating. If a channel goes into the DDT gain reduction mode, the DDT LED illuminates. The clipping percentage or output power is instantly reduced. When a problem occurs that causes a channel to go into a prote
Summary of the content on the page No. 15
Protection Features ™ RampUp Signal Control ® Whenever a CS Series amplifier powers up or comes out of a protect mode, the RampUp circuit activates. While the ™ speakers are disconnected, the RampUp circuit fully attenuates the signal and activates the DDT LED. After the output relay closes, the signal slowly and gradually raises up to its set level. The PWR LED will illuminate and the DDT LED will turn off when the signal is no longer attenuated. The RampUp Signal Control circuit has some i
Summary of the content on the page No. 16
Amplifier Maintenance and User Responsibility A CS Series amplifier requires no routine maintenance and should not need internal adjustment during its lifetime. Your CS Series amplifier is very powerful and can be potentially dangerous to loudspeakers and humans alike. It is your responsibil- ity to read the Important Precautions section and to make sure that the amplifier is installed, wired and operated properly as instructed in this manual. Many loudspeakers can be easily damaged or destroyed
Summary of the content on the page No. 17
® CS Series 3000/4000/4080 HZ Power Amplifiers SPECIFICATIONS CS 3000 CS 4000 CS 4080 HZ 3,050 watts @ 1 kHz at 4,000 watts @ 1 kHz at 4,080 watts @ 1 kHz at Rated Power Bridged <0.1% T.H.D. @ 4 ohms <0.1% T.H.D. @ 4 ohms <0.1% T.H.D. @ 8 ohms 1,500 watts per channel 2,000 watts per channel N/A Rated Power 2 x 2 ohms @ 1 kHz <0.05% T.H.D. @ 1 kHz <0.1% T.H.D. both channels driven both channels driven 1,025 watts per channel 1,350 watts per channel 2,040 watts per channel Rated Power 2 x
Summary of the content on the page No. 18
® CS Series SPECIFICATIONS CS 3000 CS 4000 CS 4080 HZ > 15V/us > 15V/us > 15V/us Slew Rate > 500:1 @ 20 Hz - 1 > 500:1 @ 20 Hz - 1 > 500:1 @ 20 Hz - 1 Damping Factor (8 ohms) kHz kHz kHz +5 to - 15 degrees from +5 to - 12 degrees from +5 to - 12 degrees from Phase Response 20 Hz to 20kHz 20 Hz to 20kHz 20 Hz to 20kHz 1.6 volts +/- 3% for 1 1.84 volts +/- 3% for 1 2.25 volts +/- 3% for 1 Input Sensitivity kHz. 4 ohms rated power, kHz. 4 ohms rated power, kHz. 4 ohms rated power 1.37 volts
Summary of the content on the page No. 19
DEUTSCH ® 3 4 4 CS 000/ 000/ 080 HZ Endstufen Herzlichen Glückwunsch zum Kauf einer Endstufe der CS Series von Peavey! Die Verstärker der CS Series wurden für einen zuverlässigen Betrieb und lange Lebensdauer entwickelt. In einem robusten, kompakten Gerät bieten sie die überragende Schallleistung und die unübertroffene Zuverlässigkeit, für die Peavey bekannt ist. Fortschrittliche Technologien und umfassende Schutzschaltungen ermöglichen einen effizienteren Betrieb auch bei problematischen L