Summary of the content on the page No. 1
TM
pass
X260.5 Owner’s Manual
Sept 23, 2009
1
X260.5 Owners Manual
Summary of the content on the page No. 2
Introduction The Pass Laboratories ™ X260.5 mono amplifier embodies the design technology and refinements of the “X” series amplifiers including exten- sions of the patented Supersymmetry™ circuit. The Supersymmetry™ circuit topology was granted a U.S. patent in 1994, and was the result of 19 years of effort by legendary analog designer and company founder Nelson Pass. The amplifier uses highly matched com- ponents in a classically simple single ended Class A circuit. The amplifier conta
Summary of the content on the page No. 3
Century and the elegance to retrieve the micro dynamics offered by the most sensitive loudspeakers. The simple but powerful circuitry moves easily from total silence to explosive transient and back to silence without a trace and without information loss. Very unlike conventional high power amplifiers, they provide this level of power with a subtlety befitting some of the better tube amplifiers. This per- formance is consistence across the audio spectrum and the amplifiers are unconditi
Summary of the content on the page No. 4
Setup You can position this amplifier most anywhere you wish, but it re- quires adequate ventilation. We do not recommend placing it in enclosed cabinets or small closets without means for air to circulate freely. Stacking these power amplifiers directly upon each other is not recommended for the same reason. This amplifier typically idles at slightly more than 250 watts, most of which dissipates as heat across the heatsinks. As a point of reference, these heatsinks should never become t
Summary of the content on the page No. 5
Looking at the rear panel you will see the IEC 320 AC power cord receptacle, a mains power switch, two pairs of output connectors, a pair of binding post connectors for remote turn-on, one RCA input connector and one XLR balanced input connector. Make sure that the mains power switch is off (down). Plug the AC cord into the back of the amplifier, and then into the wall. Then turn the breaker switch on (up). The lights in your house may blink when the power supply charges the capacitors;
Summary of the content on the page No. 6
The amplifier can be driven single-end or balanced, if driving the am- plifier single-ended, leave the supplied jumper in place (between pins 1 & 3 on the XLR). Your amplifier will operate without the jumper in place, but performance will be significantly diminished. Now that the source component is connected, make sure there is no signal coming from it, probably by turning the volume all the way down. With the speakers connected, push the front panel button to activate the amplifier. The
Summary of the content on the page No. 7
fier. The positive of the 12 volts DC goes to the red connector. This connection has an actual operating range of about 9 volts to 15 volts at a current draw of approximately 5.0mA. This switching will over- ride the front panel button, so if you want the front panel button to operate, leave the rear connection open. So much for the most essential information. Speaker Interface The Pass Laboratories™ X260.5 is optimized for loads nominally rated at 4 ohms and above. You can run the ampli
Summary of the content on the page No. 8
Fortunately the amplifier is not sensitive to the capacitive/inductive character of some of the specialty speaker cables, so feel free to experi- ment. We have found that about 90 per cent of bad sounding cables are in reality bad sounding connections, and we recommend that special at- tention be paid to cleanliness of contact surfaces and proper fit. Speaker cables should be firmly tightened down at the speaker output terminals, but do not use a wrench. These connectors will not with- stand
Summary of the content on the page No. 9
For more information please contact: Pass Laboratories Inc. P.O. Box 219, 24449 Foresthill Rd., Foresthill, CA 95631 Tel: 530.367.3690 Fax: 530.369.2193 www.passlabs.com © 2009, Pass Laboratories Inc. “Pass”, “ pass”, “Pass Labs”, “Pass Laboratories”, Supersymmetery”, “Aleph”, and “Zen” and are all registered trademarks of Pass Laboratories, Inc., and all rights thereto are protected by law. 9 X260.5 Owners Manual
Summary of the content on the page No. 10
Warranty Information Please check with the factory-authorized distributor in the country you are purchasing this product for specific warranty information. All Pass Laboratories products purchased from an authorized Pass Labora- tories dealer in North America are covered by a transferable, limited 3-year warranty. This warrantee includes all parts and labor charges incurred at the repair facility in addition to return shipping to the domestic customer, exclu- sive of subsequent damages. Dam
Summary of the content on the page No. 11
For your protection please Water and moisture: Electrical devices should not be used near water ( read the following: as per example, near a bathtub, washbasin, kitchen sink, laundry tub, wet basement or swimming pool ). Care should be taken such that objects do not have the opportunity to fall, and that liquid is never spilled onto or into the device enclosure through openings. Power Sources: An electrical device must be connected to a mains power source in strict accordance with the s