National Instruments PXI NI PXI-1052 user manual

User manual for the device National Instruments PXI NI PXI-1052

Device: National Instruments PXI NI PXI-1052
Category: Switch
Manufacturer: National Instruments
Size: 2.12 MB
Added : 9/15/2013
Number of pages: 70
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for National Instruments PXI NI PXI-1052. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with National Instruments PXI NI PXI-1052.

For your convenience

If looking through the National Instruments PXI NI PXI-1052 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual National Instruments PXI NI PXI-1052 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual National Instruments PXI NI PXI-1052 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
National Instruments PXI NI PXI-1052 User manual - Online PDF
Advertisement
« Page 1 of 70 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual National Instruments PXI NI PXI-1052 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to National Instruments PXI NI PXI-1052. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

PXI
NI PXI-1052 User Manual
NI PXI-1052 User Manual
April 2004 Edition
Part Number 371087A-01

Summary of the content on the page No. 2

Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100 Worldwide Offices Australia 1800 300 800, Austria 43 0 662 45 79 90 0, Belgium 32 0 2 757 00 20, Brazil 55 11 3262 3599, Canada (Calgary) 403 274 9391, Canada (Ottawa) 613 233 5949, Canada (Québec) 450 510 3055, Canada (Toronto) 905 785 0085, Canada (Vancouver) 514 685 7530, China 86 21 6555 7838, Czech Republic 420

Summary of the content on the page No. 3

Important Information Warranty The NI PXI-1052 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. This warranty includes parts and labor. The media on which you receive National Instruments software are warranted not to fail to execute programming instructions,

Summary of the content on the page No. 4

Contents About This Manual Conventions ...................................................................................................................vii Related Documentation..................................................................................................viii Chapter 1 Getting Started Unpacking......................................................................................................................1-1 What You Need to Get Started ................................

Summary of the content on the page No. 5

Contents Installing SCXI Modules............................................................................................... 2-10 Installing Optional SCXI-1360 Filler Panels .................................................. 2-10 PXI System Configuration with MAX.......................................................................... 2-10 Basic PXI System Configuration .................................................................... 2-11 Trigger Configuration in MAX.....................

Summary of the content on the page No. 6

About This Manual The NI PXI-1052 User Manual contains information about installing, configuring, using, and maintaining the NI PXI-1052 chassis. Conventions The following conventions are used in this manual: » The » symbol leads you through nested menu items and dialog box options to a final action. The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box. This icon denotes a note, which alerts you t

Summary of the content on the page No. 7

About This Manual Related Documentation The following documents contain information that you might find helpful as you read this manual: • DAQ Quick Start Guide  SCXI Quick Start Guide  DAQ user manuals and installation guides—This documentation has detailed information about the DAQ hardware that plugs into or is connected to the chassis. Use these documents for hardware installation and configuration instructions, specification information about the DAQ hardware, and application hints.

Summary of the content on the page No. 8

1 Getting Started This chapter describes the key features of the PXI-1052 chassis and lists the kit contents and optional equipment you can order from NI. Unpacking  Carefully inspect the shipping container and the chassis for damage.  Inspect the chassis for visible damage to the metal work. Make sure all handles, hardware, and switches are undamaged.  Inspect the inner chassis for any possible damage, debris, or detached components. If damage appears to have been caused during shipment,

Summary of the content on the page No. 9

Chapter 1 Getting Started Table 1-1. AC Power Cables Power Cable Reference Standards Standard 120 V (USA) ANSI C73.11/NEMA 5-15-P/IEC83 North America 120 V ANSI C73.20/NEMA 5-15-P/IEC83 Switzerland 220 V SEV Universal Euro 230 V CEE (7), II, IV, VII IEC83 Australia 240 V AS C112 United Kingdom 230 V BS 1363/IEC83 If you are missing any of the items in Table 1-1, or if you have the incorrect AC power cable, contact NI through the information given in Appendix C, Technical Support and Professio

Summary of the content on the page No. 10

Chapter 1 Getting Started  Over-current protection through push-reset circuit breaker (no AC-input fuse to replace)  Remote PXI voltage monitoring and inhibit through a rear-panel connector  On/Off (Standby) power switch on the front panel for easy access  SCXI power switch on the chassis rear panel  Front-panel LED that indicates power supply failure  Handle for portability  Tilt feet for bench-top applications  Rack mountable © National Instruments Corporation 1-3 NI PXI-1052 User Ma

Summary of the content on the page No. 11

Chapter 1 Getting Started Chassis Description Figure 1-1 and Figure 1-2 show the key features of the PXI-1052 chassis front and rear panels. 1 2 3 4 5 6 7 LV ANALOG HV ANALOG NATIONAL BUS BUS INSTRUMENTS ! SYSTEM SCXI 300V CAT II NI PXI-1052 POWER POWER 17 8 16 15 2 3 4 1 8 9 14 13 12 11 10 8 1 On/Off (Standby) System Power Switch 10 SCXI Module Slots 2 System Power Indicator LED 11 PXI Peripheral Slots 3 SCXI Subsystem Power Indicator LED 12 PXI Star Trigger/Peripheral Slot 4 SCXI Low-Voltag

Summary of the content on the page No. 12

Chapter 1 Getting Started 1 2 3 4 1 11 10 9 8 5 1 7 6 1 Filter Retainer Screws 7 Chassis Ground Screw 2 SCXI Subsystem Power Switch 8 Circuit Breaker 3 Remote Inhibit and Voltage Monitoring Connector 9 SCXI Auxiliary I/O Connector 4 Fan Speed Selector Switch 10 SCXI High-Voltage Analog Bus Connector 5Filter Cover 11 SCXI Low-Voltage Analog Bus Connector 6 Universal AC Inlet Figure 1-2. Rear View of the PXI-1052 Chassis Optional Equipment Contact NI to order the following options for the PXI-105

Summary of the content on the page No. 13

Chapter 1 Getting Started Interoperability with CompactPCI The PXI-1052 backplane is interoperable with 5 V and universal PXI-compatible products and standard CompactPCI products. This is an important feature because some PXI user systems can require components that do not implement PXI-specific features. For example, you may want to use a standard CompactPCI network interface card in a PXI chassis. The signals on the backplane P1 connectors meet the requirements of the CompactPCI specifica

Summary of the content on the page No. 14

Chapter 1 Getting Started Local Bus The PXI backplane local bus is a daisy-chained bus that connects each peripheral slot with adjacent peripheral slots to the left and right as shown in Figure 1-3. For example, the Slot 2 right local bus connects to the Slot 3 left local bus, and so on. The left local bus signal lines on Slot 2 are used for the star trigger and do not connect to Slot 1. The right local bus signal lines on Slot 4 are used for SCXI communication. Each local bus is 13 lines w

Summary of the content on the page No. 15

Chapter 1 Getting Started System Reference Clock The PXI-1052 supplies the PXI 10 MHz system clock signal (PXI_CLK10) independently to each peripheral slot. An independent buffer (having a source impedance matched to the backplane and a skew of less than 500 ps between slots) drives the clock signal to each peripheral slot. You can use this common reference clock signal to synchronize multiple modules in a measurement or control system. You can drive PXI_CLK10 from an external source throu

Summary of the content on the page No. 16

2 Installation and Configuration This chapter describes how to install, configure, and use the PXI-1052 chassis. Before connecting the chassis to a power source, read this chapter and the Read Me First: Safety and Radio-Frequency Interference document included with the chassis. Safety Information Caution Before undertaking any troubleshooting, maintenance, or exploratory procedure, carefully read the following caution notices. This equipment contains voltage hazardous to human life and safet

Summary of the content on the page No. 17

Chapter 2 Installation and Configuration  Modification—Do not modify any part of the chassis from its original condition. Unsuitable modifications may result in safety hazards. Chassis Cooling Considerations The PXI-1052 is designed to operate on a bench or in an instrument rack. Determine how you want to use the PXI-1052 and follow the appropriate installation instructions. Providing Adequate Clearance Openings in the top and along both sides of the chassis facilitate power supply and modu

Summary of the content on the page No. 18

Chapter 2 Installation and Configuration Tip Install the chassis so that you can access the rear panel easily. This simplifies cleaning or replacing the air filters. Setting Fan Speed The fan-speed selector switch is on the rear panel of the PXI-1052. Refer to Figure 1-2, Rear View of the PXI-1052 Chassis, to locate the fan-speed selector switch. Select HIGH for maximum cooling performance (recommended) or AUTO for quieter operation. The fan speed is determined by chassis intake air tempera

Summary of the content on the page No. 19

Chapter 2 Installation and Configuration Connecting Safety Ground Caution The PXI-1052 chassis is designed with a three-position NEMA 5-15 style plug for the United States that connects the ground line to the chassis ground. To minimize shock hazard, make sure the electrical power outlet you use to power the chassis has an appropriate earth safety ground. If the power outlet does not have an appropriate ground connection, you must connect the premise safety ground to the chassis grounding sc

Summary of the content on the page No. 20

Chapter 2 Installation and Configuration Power Switch LED Indicators The chassis has two LEDs next to the power switch. The system power LED indicates the power status for the chassis. The SCXI power LED, when lit, indicates that power is available to the SCXI subsystem. The system power LED indicates one of three different conditions. 1. If the system power LED is steady green (not flashing), the chassis is powered on and operating normally. Caution Operating the PXI system outside of the s


Alternative user manuals
# User manual Category Download
1 National Instruments 1192 User manual Switch 1
2 National Instruments 6024E User manual Switch 3
3 National Instruments 6023E User manual Switch 2
4 National Instruments 1191 User manual Switch 0
5 National Instruments 6025E User manual Switch 0
6 National Instruments 653X User manual Switch 0
7 National Instruments 7334 User manual Switch 0
8 National Instruments 7344 User manual Switch 2
9 National Instruments 7340 PCI User manual Switch 3
10 National Instruments 800 Series User manual Switch 0
11 National Instruments AT-MIO-16X User manual Switch 0
12 National Instruments 6527 User manual Switch 2
13 National Instruments Compact FieldPoint Mounting Accessories cFP-21xx User manual Switch 8
14 National Instruments DIO 6533 User manual Switch 1
15 National Instruments GPIB-BUF User manual Switch 0
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4