National Instruments NI UES-3880 user manual

User manual for the device National Instruments NI UES-3880

Device: National Instruments NI UES-3880
Category: Switch
Manufacturer: National Instruments
Size: 0.3 MB
Added : 9/15/2013
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for National Instruments NI UES-3880. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with National Instruments NI UES-3880.

For your convenience

If looking through the National Instruments NI UES-3880 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual National Instruments NI UES-3880 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual National Instruments NI UES-3880 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
National Instruments NI UES-3880 User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual National Instruments NI UES-3880 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to National Instruments NI UES-3880. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1











NI UES-3880

Hardware Installation Guide










First Edition, Sept 2007











P/N: 1802003080110

Summary of the content on the page No. 2

Overview The NI UES-3880 is a smart Ethernet switch that provides an economical solution for your Ethernet connections. As an added bonus, the built-in smart alarm function helps system maintainers monitor the health of your Ethernet network. The NI UES-3880 has a wide operating temperature range of -40 to 75ºC, and is designed to withstand a high degree of vibration and shock. The rugged hardware design makes either model perfect for ensuring that your Ethernet equipment can withstand

Summary of the content on the page No. 3

ON DIP 123 456 78 Panel Layout Front Panel View 2 1. Grounding screw 5 2. Terminal block for power inputs 6 7 PWR1/PWR2 and relay output 11 3. Heat dissipation orifices 4. DIP switches 8 5. Power input PWR1 LED 6. Power input PWR2 LED 7. Fault LED 9 8. 10/100BaseT(X) Port 10 9. TP port’s 100 Mbps LED 10. TP port’s 10 Mbps LED Top Panel View 11. Model Name 1 12. Screw holes for wall mounting kit V2+ PWR2 V2- 13. DIN-rail Kit FAULT 2 V1+ PWR1 V1- V1

Summary of the content on the page No. 4

Mounting Dimensions (unit = mm) 21.00 30.00 54.00 9.50 Side View 135.00 (unit = mm) 105.00 15.10 13.90 13.90 13.10 18.20 25.40 9.75 3.50 + + 6 + + 6.00 26 + + 3.50 + + 10 + + 6.00 + + 10 5 30.50 7.75 7.75 13 18 13 135.00 + + + + + + + + + + + + Front View Rear View Panel Mount Kit — 3 — 23.15 46.77 39.37 25.71

Summary of the content on the page No. 5

DIN-rail Mounting The aluminum DIN-rail attachment plate should already be fixed to the back panel of the switch when you take it out of the box. If you need to reattach the DIN-rail attachment plate, make sure the stiff metal spring is situated towards the top, as shown in the figures below. STEP 1: STEP 2: Insert the top of the DIN-rail into the The DIN-rail attachment unit will slot just below the stiff metal spring. snap into place as shown below. metal metal spring spring DIN-Rail

Summary of the content on the page No. 6

STEP 3: Once the screws are fixed in the wall, insert the four screw heads through the large parts of the keyhole-shaped apertures, and then ⇒ slide the NI UES-3880 downwards, as indicated. Tighten the four screws for added stability. Wiring Requirements WARNING Do not disconnect modules or wires unless the power supply has been switched off or the area is known to be non-hazardous. The devices may only be connected to the supply voltage shown on the type plate. The devices are

Summary of the content on the page No. 7

You should also pay attention to the following items: Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection point. NOTE: Do not run signal or communications wiring and power wiring in the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately. You can use the type of signal transmitted through a wire to determine

Summary of the content on the page No. 8

STEP 1: Insert the negative/positive DC wires into the V-/V+ terminals. Top View STEP 2: To keep the DC wires from pulling loose, use a small flat-blade screwdriver to tighten the wire-clamp screws on the front of the terminal block connector. Front View STEP 3: Insert the plastic terminal block connector prongs into the terminal block receptor, which is located on the NI UES-3880’s top panel. ATTENTION Before connecting the NI UES-3880 to the DC power inputs, make sure the

Summary of the content on the page No. 9

RJ45 (8-pin) to RJ45 (8-pin) Cross-Over Cable Wiring Switch Port Cross-Over Cable Switch Port (NIC Port) (NIC Port) RJ45 Plug Pin 1 RJ45 RJ45 Connector Cable Wiring Connector (Rx+) Tx+ 3 1 Rx+ (Tx+) (Rx-) Tx- 6 2 Rx- (Tx-) (Tx+) Rx+ 1 3 Tx+ (Rx+) (Tx-) Rx- 2 6 Tx- (Rx-) Redundant Power Inputs Both power inputs can be connected simultaneously to live DC power sources. If one power source fails, the other l

Summary of the content on the page No. 10

LED Indicators The front panel of the NI Switch contains several LED indicators. The function of each LED is described in the table below. LED Color State Description Power is being supplied to power input On PWR1 AMBER PWR1 Power is not being supplied to power Off input PWR1 Power is being supplied to power input On PWR2 PWR2 AMBER Power is not being supplied to power Off input PWR2 When the corresponding PORT alarm is On enabled, and the port’s link is inactive. When th

Summary of the content on the page No. 11

where it is not needed. Packets that are used in maintaining the operation of the network (such as the occasional multi-cast packet) are forwarded to all ports. The NI UES-3880 operates in the store-and-forward switching mode, which eliminates bad packets and enables peak performance to be achieved when there is heavy traffic on the network. Switching and Address Learning The NI UES-3880 has an address table that can hold up to 1K node addresses, which makes it suitable for use with lar

Summary of the content on the page No. 12

Specifications Technology Standards IEEE802.3, 802.3u, 802.3x Forward and Filtering 148810 pps Rate Packet Buffer Memory 256 KB Store and Forward, with IEEE802.3x full duplex, Processing Type back pressure flow control Address Table Size 1K uni-cast addresses Latency Less than 5 μs Interface 10/100BaseT(X) auto negotiation speed, F/H duplex RJ45 Ports mode, and auto MDI/MDI-X connection LED Indicators Power, Fault, 10M, 100M DIP Switch Port break alarm mask One relay output

Summary of the content on the page No. 13

Technical Support and Professional Services Visit the following sections of the National Instruments Web site at ni.com for technical support and professional services: • Support— Online technical support resources at ni.com/support include the following: Self-Help Resources— For answers and solutions, visit the award-winning National Instruments Web site for software drivers and updates, a searchable KnowledgeBase, product manuals, step-by-step troubleshooting wizards, thousands

Summary of the content on the page No. 14

Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500 North Mopac ExpresswayAustin, Texas 78759-3504USATel: 512 683 0100 Worldwide Offices Australia 1800 300 800, Austria 43 662 457990-0, Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599, Canada 800 433 3488, China 86 21 5050 9800, Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, Finland 358 (0) 9 725 72511, France 01 57 66 24 2


Alternative user manuals
# User manual Category Download
1 National Instruments 1192 User manual Switch 1
2 National Instruments 6024E User manual Switch 3
3 National Instruments 6023E User manual Switch 2
4 National Instruments 1191 User manual Switch 0
5 National Instruments 6025E User manual Switch 0
6 National Instruments 653X User manual Switch 0
7 National Instruments 7334 User manual Switch 0
8 National Instruments 7344 User manual Switch 2
9 National Instruments 7340 PCI User manual Switch 3
10 National Instruments 800 Series User manual Switch 0
11 National Instruments AT-MIO-16X User manual Switch 0
12 National Instruments 6527 User manual Switch 2
13 National Instruments Compact FieldPoint Mounting Accessories cFP-21xx User manual Switch 8
14 National Instruments DIO 6533 User manual Switch 1
15 National Instruments GPIB-BUF User manual Switch 0
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4