N-Tron 400 user manual

User manual for the device N-Tron 400

Device: N-Tron 400
Category: Switch
Manufacturer: N-Tron
Size: 0.74 MB
Added : 3/15/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for N-Tron 400. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with N-Tron 400.

For your convenience

If looking through the N-Tron 400 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual N-Tron 400 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual N-Tron 400 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
N-Tron 400 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual N-Tron 400 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to N-Tron 400. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1















400 Series
Industrial Ethernet Switches

Installation
Guide




















Rev 102507 1

Summary of the content on the page No. 2

Industrial Ethernet Switch Installation Guide 405TX 405FX-SC 405FX-ST 405FXE-SC-YY 405FXE-ST-YY Where: YY = -15, -40, or -80 Rev 102507 2

Summary of the content on the page No. 3

Copyright, © N-TRON Corp., 2005 820 S. University Blvd., Suite 4E Mobile, AL 36609 USA All rights reserved. Reproduction, adaptation, or translation without prior written permission from N-TRON Corp. is prohibited, except as allowed under copyright laws. Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks of their respective owners. The information contained in this doc

Summary of the content on the page No. 4

Safety Warnings ELECTRICAL SAFETY WARNING: Do not disconnect while circuit is live, unless area is known to be non-hazardous. WARNING: Disconnect the power cable before removing the enclosure top. WARNING: Do not operate the unit with the top cover removed. WARNING: Do not work on equipment or cables during periods of lightning activity. WARNING: Do not perform any services on the unit unless qualified to do so. WARNING: Do not block the air vents. WARNING: Observe p

Summary of the content on the page No. 5

405FX, 405FXE, & 405TX Industrial Ethernet Switches The 405TX and 405FX Unmanaged Industrial Ethernet Switches support high speed layer 2 switching between ports. The 405TX is an affordable 5 port unmanaged switch that is capable of auto negotiating 10/100 Mb and half/full duplex communications. The N-TRON 405TX is housed in a ruggedized steel enclosure, and provides 5 Category 5 compliant 10/100-BaseT connections for high performance network design, and hub/repeater upgrades. Th

Summary of the content on the page No. 6

PACKAGE CONTENTS Please make sure the Ethernet Switch package contains the following items: 1. 405FX/405FXE/405TX Ethernet Switch 2. This Installation Guide Contact your carrier if any items are damaged. INSTALLATION Read the following warning before beginning the installation: WARNING The 405FXE unit contains a Class 1 Laser. Do not stare into the laser beam (fiber optic connector) when installing or operating the product. Never install or work on electrical equip

Summary of the content on the page No. 7

405FX/405FXE HALF DUPLEX SETUP While all RJ45 ports are Autosensing, the 405FX/405FXE Fiber Optic Port is factory configured for full duplex operation. In the event half duplex operation is desired, follow these steps: 1. Remove the Voltage Input Power Plugs. 2. Remove the top cover (8 screws). 3. Remove the jumper plug (JP1) from pins 1 and 2. 4. Replace the top cover. 5. Proceed with the installation. Full Duplex = Pins 1 and 2 shorted. Half Duplex = Remove jumper.

Summary of the content on the page No. 8

DIN-Rail Mounting Install the unit in a standard DIN-Rail. Recess the unit to allow at least 5” of horizontal clearance for fiber optic cable bend radius (2” for TX models). Note: This unit may be mounted horizontally or vertically. To install the unit to 35mm industrial DIN-Rail - Place the top edge of the included mounting bracket on the back of the unit against the top flange of the DIN-Rail at a 15° angle. Rotate the bottom of the unit to the back (away from you) until it snaps

Summary of the content on the page No. 9

FRONT PANEL From Left to Right: LNK Link LED for Fiber Optic Port (405FX/FXE only) TX Fiber Optic Transmit Port (405FX/FXE Only) RX Fiber Optic Receive Port (405FX/FXE Only) ACT Activity LED for Fiber Optic Port (405FX/FXE only) X RJ45 Crossover Uplink Port (405TX Only) RJ45 Ports Auto sensing 10/100BaseT Connections ! Red LED indicates controller error Green LED lights when Power is connected NOTE: Each RJ45 data port has two LED’s located at the top of each con

Summary of the content on the page No. 10

LED’s: The table below describes the operating modes: LED Color Description GREEN Power is Applied OFF Power is OFF RED Controller HW Error ! OFF No Errors. Normal Operation. GREEN Link between ports LNK established OFF No Link between ports GREEN Data is active between ACT ports OFF Data is inactive between ports APPLYING POWER (Side View) Unscrew & Remove the DC Voltage Input Plug(s) from the side header Install the DC Power Cables into the Plug(s) (obs

Summary of the content on the page No. 11

N-TRON SWITCH GROUNDING TECHNIQUES The grounding philosophy of any control system is an integral part of the design. N-Tron switches are designed to be grounded, but the user has been given the flexibility to float the switch when required. The best noise immunity and emissions (i.e. CE) are obtained when the N-Tron switch chassis is connected to earth ground via a drain wire. Some N-Tron switches have metal din-rail brackets that can ground the switch if the din-rail is grounded. In

Summary of the content on the page No. 12

RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration below for your Cat5 cable specifications: Rev 102507 12

Summary of the content on the page No. 13

CONNECTING THE UNIT For 405FX & 405FXE units, remove the dust cap from the fiber optic connectors and connect the fiber optic cables. The TX port on the 405FX should be connected to the RX port of the far end station. The RX port on the 405FX should be connected to the TX port of the far end station. For 10/100 Base-TX ports, plug a Category 5 twisted pair cable into the RJ45 connector. Connect the other end to the far end station. Verify that the LNK LED’s are ON once the connectio

Summary of the content on the page No. 14

KEY SPECIFICATIONS Physical Height: 2.13" (5.41 cm) Width: 5.00" (12.70 cm) Depth: 3.00" (7.62 cm) Weight: ~ 1.2 lbs. (0.6 kg) (Note: can be mounted horizontally or vertically) Electrical Input Voltage: 10-30 VDC (Regulated) Input Current: 220mA max. @ 24VDC (Steady State) Inrush Current: 14.0Amp/0.9ms max. @ 24VDC Input Ripple: Less than 100 mV Input Wire Size: 16-28 AWG Environmental Operating Temperature: -20°C to 70°C Storage Temperature: -40°C to

Summary of the content on the page No. 15

Regulatory Approvals: Safety: UL 1604 (US and Canada) Hazardous Locations, Class I, Zone 2, Group IIC, T4A EMI: EN55022 – Class A FCC Part 15 Class A EMS: EN55024:1998 EN61000-4-2:1995 EN61000-4-3:1997 EN61000-4-4:1995 EN61000-4-5:1995 EN61000-4-6:1996 GOST-R Certified. Warranty: 1 year from the date of purchase Rev 102507 15

Summary of the content on the page No. 16

N-TRON Limited Warranty N-TRON, Corp. warrants to the end user that this hardware product will be free from defects in workmanship and materials, under normal use and service, for the applicable warranty period from the date of purchase from N-TRON or its authorized reseller. If a product does not operate as warranted during the applicable warranty period, N-TRON shall, at its option and expense, repair the defective product or part, deliver to customer an equivalent product or part to re


Alternative user manuals
# User manual Category Download
1 N-Tron 1003GX2 User manual Switch 0
2 N-Tron 202MC User manual Switch 1
3 N-Tron 105TX-POE User manual Switch 6
4 N-Tron 105FX-POE User manual Switch 0
5 N-Tron 300 User manual Switch 3
6 N-Tron 304TX-N User manual Switch 5
7 N-Tron 104TX User manual Switch 1
8 N-Tron 400 Series User manual Switch 0
9 N-Tron 405FXE-SC-YY User manual Switch 0
10 N-Tron 405FX-ST User manual Switch 3
11 N-Tron 308TX-N User manual Switch 0
12 N-Tron 405FXE-ST-YY User manual Switch 0
13 N-Tron 405FX-SC User manual Switch 1
14 N-Tron 509FX User manual Switch 3
15 N-Tron 524TX-A User manual Switch 1
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4