NPort 6110 Modbus/TCP
to Serial Communication Gateway
User’s Manual
Third Edition, April 2005
Moxa Technologies Co., Ltd.
Tel: +886-2-8919-1230
Fax: +886-2-8919-1231
Web: www.moxa.com
MOXA Technical Support
Worldwide: support@moxa.com.tw
The Americas: support@moxa.com
Summary of the content on the page No. 2
2 NPort 6110 Modbus/TCP to Serial Communication Gateway The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement. Copyright Notice Copyright © 2005 Moxa Technologies Co., Ltd. All rights reserved. Reproduction without permission is prohibited. Trademarks MOXA is a registered trademark of The Moxa Group. All other trademarks or registered marks in this manual belong to their respective ma
Summary of the content on the page No. 3
MOXA Internet Services Customer satisfaction is our number one concern. To ensure that customers receive the full benefit of our products, Moxa Internet Services has been set up to provide technical support, driver updates, product information, and user’s manual updates. The following services are provided: E-mail for technical support Worldwide: support@moxa.com.tw The Americas: support@moxa.com World Wide Web (WWW) site for product information address: http://www.mox
Summary of the content on the page No. 4
Table of Contents 1. Introduction.......................................................................................1-1 Overview.......................................................................................1-1 Features........................................................................................1-2 Product Specifications ..................................................................1-3 Package Checklist .........................................................
Summary of the content on the page No. 5
Upgrade Firmware ..............................................................4-15 Remote Monitoring and Management.................................4-17 5. Troubleshooting ...............................................................................5-1 6. Pin Assignments...............................................................................6-1 A. Declaration of Conformity.............................................................. A-1 B. Problem Report Form.....................
Summary of the content on the page No. 6
1 1 1.Introduction Welcome to Moxa NPort 6110 Modbus/TCP to Serial Communication Gateway, an easy-to-use Ethernet to RS-232/422/485 Modbus Gateway. This chapter is an introduction to NPort 6110 and includes the following sections: Overview Features Product Specifications Package Checklist Front/Top/Rear/Bottom Panel Views Overview Moxa NPort 6110 Modbus/TCP to Serial Communication Gateway provides users with many excellent benefits, including: Seamless integration of Eth
Summary of the content on the page No. 7
port that can connect to many types of Modbus device. By translating Modbus/TCP (Ethernet) and Modbus/ASCII/RTU (Serial) protocols, a PLC with Ethernet can use the RS-232/485 interface to seamlessly communicate with instruments. Powerful operation modes for versatile Modbus applications For Modbus protocol conversions, it is necessary to define a Master and Slave device, but unlike other Modbus Gateways, NPort 6110 allows users to configure Master/Slave for both the Ethernet and serial
Summary of the content on the page No. 8
Product Specifications LAN Ethernet 10/100 Mbps, RJ45 Protection Built-in 1.5 KV magnetic isolation Serial Interface RJ-232/422/485 x 1, DB9 (M), software selectable RS-232 Signals TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND RS-422 Signals Tx+, Tx-, Rx+, Rx-, RTS+, RTS-, CTS+, CTS-, GND RS-485 2-wire Signals Data+(A), Data-(B), GND Serial Line Protections 15 KV ESD for all signals RS-485 Data Direction Patented ADDC™ (Automatic Data Direction Control) Serial Communication Parameters Pa
Summary of the content on the page No. 9
Environmental Operating Temperature 0 to 55°C (32 to 131°F), 5 to 95% RH Storage Temperature -20 to 85°C (-4 to 185°F), 95% RH Regulatory Approvals EMC FCC Class B, CE Class B Safety CUL, TÜV Package Checklist NPort 6110 Modbus/TCP to Serial Communication Gateway with 100-240 VAC power adaptor (US, Euro plugs included) All models include: NPort 6110 Software and documentation CD-ROM 100-240 VAC power adapter, US plug, 12V, 400 mA Euro plug included Optional Accessories:
Summary of the content on the page No. 10
Front/Top/Rear/Bottom Panel Views RESET 10/100M 9-30V Ethernet 6 (0.24") PWR 4 Link (0.16") Ready 6110 Modbus/TCP to Serial Communication Gateway 21.3 7 (0.28") (0.8") RS-232/422/485 42.3 (1.67") unit = mm (inch) 67 (2.64") 78 (3.07") 90.2 (3.55") 1-5 100.4 (3.95") 22.0 12.5 (0.49") (0.87") 25 (0.98")
Summary of the content on the page No. 11
2 2 2.Getting Started This chapter includes: Power Connection Serial Installation Ethernet Installation Software Installation Housing DIN-Rail Wall Mount Power Connection Take the following steps to connect NPort 6110’s power adapter. 1. Plug the power adapter’s DC plug into NPort 6110’s DC-IN jack. 2. Plug the power adapter into an electrical outlet. Note that there is no on/off switch. NPort 6110 automatically turns on when plugged into the outlet, and the red PWR
Summary of the content on the page No. 12
Ethernet Installation There are two ways to use the 10/100BaseT Ethernet jack located on NPort 6110’s front panel: 1. For most applications using NPort 6110, you will simply plug one end of an Ethernet cable into NPort 6110’s 100BaseT jack, and plug the other end into an Ethernet hub/switch connected to your network. In this case, use a regular straight-through Ethernet cable. 2. When configuring NPort 6110, you may connect NPort 6110 directly to your computer’s Ethernet connector. To
Summary of the content on the page No. 13
2. You will be greeted by the Welcome window. Click on Next to continue. 3. Enter your Name and Company name in the spaces provided, and then click on Next to continue. 4. When the Choose Destination Location window appears, click on Next to continue. If you would like to use a Destination Directory different than the one displayed, first click on Browse… to locate your folder of choice, and then click on Browse. 2-3
Summary of the content on the page No. 14
5. If desired, modify the highlighted name in the Program Folders text box (this is the name that will appear under Start Programs) and then click on Next to continue. 2-4
Summary of the content on the page No. 15
6. Click on Next to start copying the software files. 7. Wait patiently while the files are being copied. The procedure should only take a few seconds. 8. The NPort Modbus Gateway Utility folder will open showing the Modbus Gateway Configurator icon. 2-5
Summary of the content on the page No. 16
9. You may also view this program shortcut by clicking on Start Programs NPort Modbus Gateway Utility Modbus Gateway Configurator, as shown below. 2-6
Summary of the content on the page No. 17
Housing DIN-Rail For many industrial applications, you will find it convenient to use the DIN-Rail attachments, as shown below. STEP 1: Use 2 screws per ear to attach DIN-Rail mounts to each of NPort 6110’s two ears. ⇒ STEP 2: Insert the top of the DIN-Rail STEP 3: Push the bottom of NPort into the top slot of the 6110 so that the bottom of the DIN-Rail mount. DIN-Rail snaps into DIN-Rail mount’s bottom slot. NOTE: The DIN-Rail mounting kit is an optional accessory. To remove
Summary of the content on the page No. 18
Wall Mount For many industrial applications, you will find it convenient to mount NPort 6110 on the wall, using two screws, as indicated below. STEP 1: Screw two screws, separated by 7.8 cm, into the wall. The heads of the screws should be no greater than 6.5 mm in diameter, and the shafts should be no greater than 3 mm in diameter. Do not screw the screws in all the way—leave a space of about 2 mm to allow room for sliding the NPort 6110 unit’s ears between the wall and the screws.
Summary of the content on the page No. 19
3 3 3.Typical Modbus Applications In this chapter, we introduce three typical Modbus applications. Serial master device talks to serial slave devices over the Internet Let traditional Modbus serial devices talk over the Internet… Many traditional serial Modbus devices can talk over RS-485, but the RS-485 network limits the maximum number of Modbus devices to 32, provided the transmission distance does not exceed 1.2 km. By using Modbus Gateway, you can link all Serial Modbus device
Summary of the content on the page No. 20
Ethernet master devices talk to multiple serial slave devices Connect all Modbus devices over the Ethernet network… Most host computers and newly developed PLCs support the Ethernet interface and run Modbus/TCP. NPort 6110 Modbus Gateway is needed to link discrete Serial Modbus Devices for data collection and control. Each NPort 6110 supports Modbus/TCP over Ethernet, which allows up to 7 connections. The software configurable serial interface supports either RS-232 or RS-422/485. In R