KTI Networks KCD-303P-A1 user manual

User manual for the device KTI Networks KCD-303P-A1

Device: KTI Networks KCD-303P-A1
Category: Switch
Manufacturer: KTI Networks
Size: 2.35 MB
Added : 5/5/2014
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for KTI Networks KCD-303P-A1. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with KTI Networks KCD-303P-A1.

For your convenience

If looking through the KTI Networks KCD-303P-A1 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual KTI Networks KCD-303P-A1 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual KTI Networks KCD-303P-A1 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
KTI Networks KCD-303P-A1 User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual KTI Networks KCD-303P-A1 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to KTI Networks KCD-303P-A1. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1




Industrial 3-Port Fast Ethernet POF
Media Converter Switches

KCD-303P-A series
KCD-303P-B series


Installation Guide












DOC.081022
1/18

Summary of the content on the page No. 2

(C) 2008 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any directive work (such as translation or transformation) without permission from KTI Networks Inc. KTI Networks Inc. reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc. to provide notification of such revision or change. For more information, contact:

Summary of the content on the page No. 3

The information contained in this document is subject to change without prior notice. Copyright (C) All Rights Reserved. TRADEMARKS Ethernet is a registered trademark of Xerox Corp. OptoLockTM is a registered trademark of Firecomms Ltd. FCC NOTICE This device complies with Class B Part 15 the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received including the inte

Summary of the content on the page No. 4

Table of Contents 1. Introduction ................................................................................................................................5 1.1 Features..............................................................................................................6 1.2 Product Panels....................................................................................................6 1.3 Specifications .................................................................

Summary of the content on the page No. 5

1. Introduction The industrial rated KCD-303P series supports three switched connections including copper and fiber for networks over POF (Plastic Optical Fiber). The copper ports support 10/100Mbps auto-negotiation and auto-MDI/MDIX for Cat.5 plug-and-play. The fiber ports support plug-less connections of high bandwidth 100Mbps data rate over POF cables. POF technology offers a complementary solution to UTP copper wire for industrial, office and home networks because it is low cost, weigh

Summary of the content on the page No. 6

Screw panel-mounting support for industrial enclosure Optional AC-DC power adapters with extended operating temperature range Industrial-rated Emission and Immunity performance 1.1 Features Supports 3 switching-base network segments – [2 x Copper, 1 x POF] and [1 x Copper, 2 x POF] Auto MDI/MDI-X crossover function on the UTP copper port Supports IEEE 802.3x flow control for full-duplex operation Supports Back-pressure flow control for half-duplex operation Wide operating temp

Summary of the content on the page No. 7

KCD-303P-B 1.3 Specifications Copper Ports Compliance IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX Connectors Shielded RJ-45 jacks Pin assignments Auto MDI/MDI-X detection Configuration Auto-negotiation Transmission rate 10Mbps, 100Mbps Duplex support Full/Half duplex Network cable Cat.5 UTP up to 100 meters POF Ports TM Connectors OptoLock connector Optical RCLED 650nm Configuration 100Mbps, Full duplex Network cables 1.5mm or 2.2mm POF (model dependent) Distance 50 meters

Summary of the content on the page No. 8

Far End Fault Support Enabled Switch Functions MAC Addresses Table 1K entries Forwarding & filtering Non-blocking, full wire speed Switching technology Store and forward Maximum packet length 1552 bytes max. Flow control IEEE 802.3x pause frame base for full duplex operation Back pressure for half duplex operation Broadcast Storm Protection design DC IN Power Input Interfaces DC IN Jack ( -D 6.3mm / + D 2.0mm) Operating Voltages +4.75 ~ 12.6VDC Power Consumption 2W max. Mechan

Summary of the content on the page No. 9

2. Installation 2.1 Unpacking The product package contains: The switch unit One AC-DC power adapter One product CD-ROM 2.2 Safety Cautions To reduce the risk of bodily injury, electrical shock, fire, and damage to the product, observe the following precautions. Do not service any product except as explained in your system documentation. Opening or removing covers may expose you to electrical shock. Only a trained service technician should service components inside these c

Summary of the content on the page No. 10

2.3 Mounting on a Wall The device can be mounted on a desktop or shelf. Make sure that there is proper heat dissipation from and adequate ventilation around the device. Do not place heavy objects on the device. To mount the device on a wall, one wall mounting hole is provided on the bottom of the device. Hang the device on the wall reliably. The following figure illustrates example of a device bottom face: 10/18

Summary of the content on the page No. 11

2.4 Panel Mounting The switches support panel mounting in industrial enclosure. A panel mounting bracket is required for the mounting. Install the bracket onto the device as shown in the figure below: After bracket installation, the final dimension is shown below: KCD-303P-A KCD-303P-B 11/18

Summary of the content on the page No. 12

2.5 Din-Rail Mounting To mount the device on a Din-rail, the optional Din-rail mounting bracket is required. Install the bracket onto the device. After bracket installation, the device is ready to be mounted on a din-rail as shown below: 12/18

Summary of the content on the page No. 13

2.6 Applying Power with Power Adapter The device provides a DC power jack for receiving DC power input from an external AC-DC power adapter. Two types of AC-DC power adapters are available for choice. One is with typical operating temperature rating and the other is with extended operating temperature rating for critical applications as follows: o o Typical Rating: 0 ~ 40 C operating temperature o o Extended Rating: -10 ~ 60 C operating temperature One power adapter is pac

Summary of the content on the page No. 14

2.7 Applying Power via USB The USB port on the common computers provides an output of 5V/500mA, equally 5V/2.5Watt, for the connected USB devices. With an USB DC power cable, the USB power is applicable to the devices and serves as a handy power, and eliminates the need for extra power adapters and occupation of limited AC power sockets. One optional “USB DC power cable” is available for purchasing to supply power for the switch via USB connection. To make the connection, the steps a

Summary of the content on the page No. 15

3. Making LAN Connections 3.1 Making Copper Port (RJ-45) Connections The copper ports support the following connection types and distances: Network Cables 10BASE-T: 2-pair UTP Cat. 3,4,5 , EIA/TIA-568B 100-ohm 100BASE-TX: 2-pair / 4-pair UTP Cat. 5, EIA/TIA-568B 100-ohm Link distance: Up to 100 meters Auto MDI/MDI-X Function This function allows the port to auto-detect the twisted-pair signals and adapts itself to form a valid MDI to MDI-X connection with the remote connected devic

Summary of the content on the page No. 16

3.2 Making POF Connections POF Cable Depending on the model specified, two different sizes of POF cables are supported. One is 1.5mm and the other is 2.2mm in diameter. The following figure illustrates 2.2mm POF and Cat.5 as comparison. Easy POF Installation The design of the device enables the POF to be cut and terminated to the exact required length on site, allowing even the most novice user to quickly and easily terminate the bare POF fiber. To terminate TM the POF cable into OptoL

Summary of the content on the page No. 17

The following figure illustrates a connection example between two POF ports located on two devices: Make sure the Rx-to-Tx connection rule is followed on the both ends of the cable. 3.3 LED Indication LED Function State Interpretation POWER Power status ON The power is supplied to the device. OFF The power is not supplied to the device. Px Link/Act. Port Px link status ON Port link is established. (No traffic) BLINK Port link

Summary of the content on the page No. 18

4. Applications 4.1 Application in Industrial Networks The following figure illustrates an application example in an industrial network. Four devices are cascaded by POF cables. 4.2 Application For Home Network The following figure illustrates an application example in home network. 4.3 Copper to POF Media Converter Application The following figure illustrates an application of copper Cat.5 to POF media conversion. 18/18


Alternative user manuals
# User manual Category Download
1 KTI Networks 10BASE-T/100BASE-TX User manual Switch 2
2 KTI Networks KF-16M User manual Switch 0
3 KTI Networks KCD-303P-B2 User manual Switch 0
4 KTI Networks 24-PORT KGS-2401 User manual Switch 2
5 KTI Networks 10BASE-T User manual Switch 1
6 KTI Networks KCD-303P-B1 User manual Switch 0
7 KTI Networks KCD-303P-A2 User manual Switch 0
8 KTI Networks Ethernet 10Base2 Transceiver KT-10B User manual Switch 1
9 KTI Networks KGS-1604 User manual Switch 5
10 KTI Networks KGD-600 User manual Switch 2
11 KTI Networks KF-16MS User manual Switch 1
12 KTI Networks KGS-2416 User manual Switch 0
13 KTI Networks KGS-2404 User manual Switch 18
14 KTI Networks KGS-510F User manual Switch 31
15 KTI Networks KGS-800L User manual Switch 2
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4