ITT 801P5 user manual

User manual for the device ITT 801P5

Device: ITT 801P5
Category: Switch
Manufacturer: ITT
Size: 0.5 MB
Added : 2/25/2013
Number of pages: 45
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for ITT 801P5. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with ITT 801P5.

For your convenience

If looking through the ITT 801P5 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual ITT 801P5 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual ITT 801P5 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
ITT 801P5 User manual - Online PDF
Advertisement
« Page 1 of 45 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual ITT 801P5 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to ITT 801P5. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


NEO-DYN
TM
801P5 SMART SWITCH
INSTALLATION AND
OPERATION MANUAL
PN 610-0002 Rev D
ECO 71349

Summary of the content on the page No. 2

Manual No. 610-0002 Rev. D Neo-Dyn 28150 Industry Drive Valencia, CA 91355 Tel: (661) 295-4000 Fax: (661) 294-1750 World Wide Web: www.neodyn.com Copyright 2002 ITT Industries Important Information ® The product warranty applicable to this ITT Neo-Dyn instrument is as stated on page 41 of this manual. Should any after-delivery problems arise, please contact ITT Neo-Dyn’s Customer Service using the information above. Our normal business hours are weekdays, 7:00 am to 3:30 pm, Paci

Summary of the content on the page No. 3

TABLE OF CONTENTS PAGE CHAPTER 1 INTRODUCTION................................................. 1 ABOUT THIS MANUAL......................................................... 4 KEYS ........................................................................................ 4 DISPLAY.................................................................................. 4 CUSTOMER SERVICE............................................................ 4 CHAPTER 2 INSTALLATION............................

Summary of the content on the page No. 4

TABLE OF CONTENTS PAGE CHAPTER 6 SERIAL COMMUNICATIONS (Z Option) .......35 GENERAL ..................................................................................35 WIRING ......................................................................................35 CHAPTER 7 SPECIFICATIONS..............................................37 STANDARD ...........................................................................37 OPTIONS ............................................................

Summary of the content on the page No. 5

CHAPTER 1 INTRODUCTION ® TM The Neo-Dyn 801P5 Smart-Switch is a solid-state pressure switch designed for a wide range of applications in pneumatic and hydraulic systems up to 3,000 psig. Pressure indication, switch status and operational status are continually displayed on the front panel. The unit can be configured to display pressure readings in a variety of formats. TM The Smart-Switch can be configured on-site, using the front panel keypad and 4 digit display, or remotely via the o

Summary of the content on the page No. 6

4-20 mA RS232 Output COM Port Status Indicators Keypad Pressure Port 1/4-18 NPT Conduit Std Connection 1/2-14 NPT 18” free leads #22 AWG TM Figure 1 Model 801P5 Smart-Switch (Mounting Brackets not Shown) Page 2 Installation and Operation Manual

Summary of the content on the page No. 7

The standard electrical interface is 22 AWG free leads exiting from a ½” - 14 NPT male conduit connection. The standard pressure connection is ¼” - 18 NPT female; a 7/16” - 20 SAE pressure connection is available as Option E. TM Output options available for the Smart-Switch include a 4-20 mA analog output (Option V), scalable display units (Option Q), and RS232 communications (Option Z). The RS232 option can be used to configure and monitor the unit ® remotely. This option includes Windo

Summary of the content on the page No. 8

ABOUT THIS MANUAL The following paragraphs describe the format conventions used in this manual. KEYS Most of the instructions contain directions to press a key, which is one of the blue touchpads on the display surface of the TM Smart-Switch . When included in instructions, the keys are shown in brackets, as [STORE]. DISPLAY When shown in the text, the LED displays are formatted as 279.3. CUSTOMER SERVICE TM If you have any questions about the 801P5 Smart-Switch that are not covered

Summary of the content on the page No. 9

CHAPTER 2 INSTALLATION TM Installation of the Smart-Switch is relatively straightforward. TM However, the Smart-Switch must be installed by a qualified electrician, in compliance with all local and national electrical codes. WARNING Electrical Hazard WARNING Do not make electrical connections while power is on. WARNING Always check for multiple circuits. Always make sure grounding is adequate. WARNING MOUNTING TM The Smart-Switch can be mounted directly to the pressure connection, o

Summary of the content on the page No. 10

ELECTRICAL CONNECTIONS Units are supplied with 22 AWG free leads exiting from a ½”-14 NPT male conduit connection. The leads are-color coded and marked. See Figure 2 for AC operation and Figure 3 for DC operation. 4-20 mA output (option letter V) is connected to the 2-pin connector on the top-right of the unit per Figure 4, using the supplied mating connector. This mating connector has solder cups that will take wires as large as #18 AWG. See Chapter 4 for operating instructions. The R

Summary of the content on the page No. 11

Figure 2 - Schematic for AC Operation TM Page 7 801P5 Smart Switch

Summary of the content on the page No. 12

Figure 3 - Schematic for DC Operation Page 8 Installation and Operation Manual

Summary of the content on the page No. 13

+ 4-20 Ma A B RETURN Figure 4 - Wiring for 4-20 mA Analog Output TM Page 9 801P5 Smart Switch

Summary of the content on the page No. 14

DATA SEND A DATA RECEIVE B SIGNAL GROUND C Figure 5 - Wiring for RS-232 Communications Page 10 Installation and Operation Manual

Summary of the content on the page No. 15

CHAPTER 3 OPERATION & PROGRAMMING This section describes the regular (normal) operation of the TM Smart-Switch as it monitors pressure after installation and initial setup, and the Programming Mode for changing the settings. Both modes rely on the front panel for information and input. See Figure 6 on the next page. OPERATION MODE To begin operation, apply correct power to the appropriate free leads (there is no on-off switch). In normal operation mode, the display shows: • Online L

Summary of the content on the page No. 16

FRONT PANEL CONTROLS Figure 6 The Front Panel, with Function Keys Below the Display Indicators Display The display shows the actual system pressure in normal operation. S1 and S2 (Switch) Indicators The S1 and S2 (red LED's) indicate switch status (illuminated with the relay coil energized or the solid-state switch actuated). Online Indicator The Online indicator (green LED) is lit when the unit is online and active. If the indicator is not lit, the unit is offline. Page 12 In

Summary of the content on the page No. 17

INPUT CONTROLS S1 and S2 INCR/DECR Push the [S1] and [S2] [INCR] and [DECR] keys to see what values the set points are configured for. MENU Use the [MENU] key to enter program mode. UP/DOWN ARROW The [UP/DOWN ARROW] keys are used to move through the list of submenus. SELECT The [SELECT] key is used to move into the desired submenu. STORE The [STORE] key is used to temporarily save changes made to the current submenu and return to the main menu. RUN The [RUN] key is used to lock in

Summary of the content on the page No. 18

DISPLAYING SET POINTS. Programmed set points can be viewed on the front panel display by pressing the corresponding [S1] or [S2] key. To view the increasing value for Switch 1, press [S1 INCR]. To view the decreasing value for Switch 2, press [S2 DECR]. Figure 7 Press the Incr / Decr Buttons to Display Set Points for S1 / S2 After 5 seconds of keypad inactivity, the display automatically NOTE changes back to the system pressure display. While viewing set points, the output function

Summary of the content on the page No. 19

STANDARD VS. WINDOW MODE The terms “Standard” and “Window” describe two methods for TM setting up the Smart-Switch to monitor pressure. Standard Mode In Standard Mode, illustrated in Figure 8, the SP1i (or SP2i) set point actuates when the pressure being monitored goes above the TM set value. At this point, the Smart-Switch might turn off whatever electrical power is being applied to a pump, for example, which is increasing or maintaining the pressure. The switch de-actuates, or resets,

Summary of the content on the page No. 20

Deadband The deadband is the separation between the increasing set point and the decreasing set point, as shown in Figure 8. The deadband can be anywhere from 1% to 99% of Full-Scale Output (F.S.O.). TM In the case above where the Smart-Switch is controlling a pump, a wider deadband reduces the frequency at which the pump cycles on and off. Window Mode This mode is useful when you want to maintain pressure within a certain range, and want to be notified when pressure either goes above


Alternative user manuals
# User manual Category Download
1 Sony 4-296-436-11 (2) User manual Switch 0
2 3Com 10/100BASE-TX User manual Switch 61
3 3Com 2226-SFP User manual Switch 688
4 3Com 16985ua.bk User manual Switch 10
5 3Com 10BASE-T User manual Switch 4
6 3Com 10BASE-2 User manual Switch 1
7 3Com 1000BASE User manual Switch 6
8 3Com 2226 PLUS User manual Switch 473
9 3Com 2250-SFP User manual Switch 538
10 3Com 1600 User manual Switch 0
11 3Com 2924-PWR User manual Switch 72
12 Sony BZPS-8001 User manual Switch 1
13 Sony DFS-700P User manual Switch 123
14 Sony DVS-9000 User manual Switch 9
15 Sony DVS-9000SF User manual Switch 5