GE Monogram 2900 Series user manual

User manual for the device GE Monogram 2900 Series

Device: GE Monogram 2900 Series
Category: Air Conditioner
Manufacturer: GE Monogram
Size: 2.36 MB
Added : 7/1/2013
Number of pages: 60
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for GE Monogram 2900 Series. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with GE Monogram 2900 Series.

For your convenience

If looking through the GE Monogram 2900 Series user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual GE Monogram 2900 Series on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual GE Monogram 2900 Series to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
GE Monogram 2900 Series User manual - Online PDF
Advertisement
« Page 1 of 60 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual GE Monogram 2900 Series but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to GE Monogram 2900 Series. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
GE Zoneline packaged
terminal air conditioners
2008 contract sales architects and engineers data manual

Summary of the content on the page No. 2

Quick Reference Full Specs on pages 54 and 55 ALL UNITS REQUIRE POWER CONNECTION KIT Power Connection Kit determines resistance heat output 7000 Btuh units do not activate 5 KW resistance heater Dry Air 25 2900 Series Cooling with Electric Heat 2900 Series Cooling with Electric Heat MODEL COOLING MODEL COOLING EER EER NUMBER (Btuh) NUMBER (Btuh) AZ29E07DA* 7100/6900 12.7/12.7 AZ29E07DAP 6800/6600 12.1/12.1 AZ29E09DA* 9300/8900 12.0/12.0 AZ29E09DAP 8800/8500 11.5/11.5 AZ29E12DA* 11700/11500

Summary of the content on the page No. 3

ge.com Power Connection Kits 230/208-Volt Line Cord Connection Units 230/208-Volt Sub-Base and Direct Connected Units Electric Electric Electric Min. Circuit Direct Electric Electric Electric Min. Circuit Line Cord Heat Heater Heat Protection Sub-Base Connection Heat Heater Heat Protection Kit BTUH Watts Amps (Amps) Kit BTUH Watts Amps (Amps) RAK 15 8600/7100 2550/2090 11.6/10.6 15 RAK204D15P RAK4157 8600/7100 2550/2090 11.6/10.6 15 RAK 20 11700/9600  450/2820 15.5/14.1 20

Summary of the content on the page No. 4

® The Zoneline 2900,  900 and 5800 Series have incorporated changes suggested by customers, along with enhancements by GE’s Technology Team and changes necessary to meet new UL and NEC requirements. “L” shaped condenser coil. The “Partial Open Vent Air” feature was a specific request by a customer. “Heat Sentinel” is an enhancement developed by GE’s Technology Team to help lodging professionals welcome their guests with a moderate-temperature room and to help lower cooling costs. Devi

Summary of the content on the page No. 5

ge.com Table of Contents Front Cover 1 Mini Specs 2900,  900 and 5800 Series 2 Mini Specs Power Connection Kits and Nomenclature  The 2900/ 900/5800 and Dry 25 4 Table of Contents 5 Introduction 6 The Zoneline System 7 Features and Benefits Features Table 8 Features and Benefits 9-11 Auxiliary Control Switches 12-1 Central Desk Control 14 Remote Thermostat Control 15-17 Heat Pumps and Energy Savings 18-19 Installation and Dimensions Application Comments 20 Case Dimensions 21 Wall Case/Sub-Ba

Summary of the content on the page No. 6

Introduction This manual is designed to provide product, performance Premium Line Standard Features: and application information to our customers and their All the Standard Features of the Deluxe Line Plus: architects and engineers for use in selection and design • T wo fan motor system with Indoor Cross Flow Blower ® of a zonal comfort control system utilizing GE Zoneline for quieter operation Packaged Terminal Air Conditioners (PTAC) and Packaged • Unit Diagnostics Terminal Heat Pump

Summary of the content on the page No. 7

ge.com ® The Zoneline System The typical Zoneline installation consists of the wall case (or sleeve), chassis, and exterior grille. Some installations may use a sub-base for support of the unit or for ease of electrical connections. Each of the components should be the standard products offered by GE or, in the case of the exterior grille, approved by GE Applications Engineering. Use of components not specifically designed or approved for use with the Zoneline can result in unsatisfactory op

Summary of the content on the page No. 8

® Zoneline Features AZ AZ AZ 2900 3900 5800 Enhanced Dehumidification — Dry Air 25 Optional N/A N/A Cooling EER Range (2 0 Volts/265 Volts) 10.2 - 12.7 10.0 - 12.7 10.2 - 1 .0 Heating COP Range (2 0 Volts/265 Volts) N/A  .2 -  .6  .2 -  .6 Heat Source — Electric Resistance Heat Standard — — Heat Source — Heat Pump With Selectable Full Time or On Demand Simultaneous/ Supplemental Resistance Heat — Standard Standard Staged Heating —  Stage  Stage Universal Heater — UPC* Standar

Summary of the content on the page No. 9

ge.com Features and Benefits Standard Physical Dimensions Reverse Cycle Heat Pump Defrost System GE has maintained the same dimensions since 1961 — Standard on all Zoneline  900 and 5800 Series heat pumps. 42" wide x 16" high x 1 - /4" deep Enables heat pump to operate at lower temperatures Replacement of older units is made easy. when other systems switch to more expensive electric resistance heat. Weather-Protected Electrical Components See pages 18 and 19 for discussion of heat pump o

Summary of the content on the page No. 10

Features and Benefits Fan-Only Setting – HIGH/LOW Indoor Coil Frost Control The unit provides the option of selecting either HIGH or LOW Prevents indoor coil from freezing speed for Fan-Only operation. and causing complaints due to lack of cooling. Frost can form on the Fan-Cycle Switch – “SmartFan” indoor coil when the unit is operated Unique “SmartFan” allows unit to operate fan continuous in in cooling when outdoor temperatures cooling operation and fan cycle in heating to provide bette

Summary of the content on the page No. 11

ge.com Features and Benefits Up-Front Air Filters Corrosion Protection (Optional) Two interchangeable 2900 and  900 Series units may be ordered with special up-front filters, easy protection to better withstand damage from salt air and to remove and reinstall, salt water in seacoast areas. may be cleaned without Corrosion protection is standard on the 5800 Series and opening or removing on Dry Air 25 models. the room front. Heat Pump units with ICR are not available with corrosion

Summary of the content on the page No. 12

Auxiliary Control Switches These switches are located behind the room cabinet under the control panel. 2900 and 3900 Series S witches Description Left Switches (1) ALL I2R Heat pump override — Down — Normal heat pump operation Up — resistance heat only ( 900 Series only) (2) C: FAN Fan control for cooling operation — Down — Fan Continuous Up — Fan Cycle ( ) H: FAN F an control for heating operation — Down — Fan Cycle Up — Fan Continuous (4) CLASS 2 R emote Therm

Summary of the content on the page No. 13

ge.com Auxiliary Control Switches These switches are located behind the room cabinet under the control panel. 5800 Series Switches Description Left Switches (1) ALL I2R Heat pump override — Down — Normal heat pump operation Up — resistance heat only (2) C: FAN Fan control for cooling operation — Down — Fan Continuous Up — Fan Cycle ( ) H: FAN F an control for heating operation — Down — Fan Cycle Up — Fan Continuous (4) CLASS 2 R emote Thermostat Mode — Down —

Summary of the content on the page No. 14

Central Desk Control Some installations may want to govern the ability of the unit 4. R ecommended wire size must be followed as a minimum to operate from a control device remote to the unit or even requirement. remote to the room in which the unit is located. The general Wire Size #AWG Maximum Allowable Length term given to systems such as this is Central Desk Control. #22 600 Ft. The most common installation of this type of system is a #20 900 Ft. switch mounted at the registration de

Summary of the content on the page No. 15

ge.com Remote Thermostat Control In some installations, control of the operation of the unit at The AC voltage may not be compatible with some a location remote from the unit itself may be desired. A unit solid-state thermostats. mounted high in the wall or over a door, for instance, where The fan speed for the 2900 Series in remote thermostat the unit-mounted controls are inaccessible, can be connected operation is selected by the connection of the fan wire from to a wall-mounted therm

Summary of the content on the page No. 16

Remote Thermostat Control Heat Pump Models Feature Heat Pump Electric Heat ® The Zoneline  900 and 5800 Series heat pump units may Indoor Frost Control Yes Yes be connected to a single-stage cooling/two-stage heating Freeze Sentinel Yes Yes thermostat designed for use with heat pump systems. GE Auto Fan Speed No No offers 2 thermostats compatible with the  900 and 5800 Electronic series units: Temperature Limiting No No Switch to Resistance Heat Based On Indoor Determined by Temperature

Summary of the content on the page No. 17

Common — Ground White — Heater ge.com Yellow — Compressor Black — Not Used On 2800 Green — High-Speed Fan Green — Low-Speed Fan Field Wiring Terminal Red — 24V AC CDC Terminal R — 24V AC GL — Low-Speed Fan G Re H s is— tan H cei g Hh- eaS t M po ed e ed ls Fan B — Reversing Valve Y — Compressor W — Heater C — Common - Ground Common — Ground White — Heater Yellow — Compressor Black — Reversing Valve Green — High-Speed Fan Green — Low-Speed Fan R

Summary of the content on the page No. 18

Heat Pumps and Energy Savings ® • GE Zoneline Heat Pumps are designed to provide Balance Point cost-efficient heat pump operation while monitoring An important consideration of the selection of a heat pump room conditions to maintain comfort. unit is the “balance point” of the installation. Virtually every The units employ a logic system monitoring both outdoor room is unique — with different insulation — different sizes and indoor temperatures to determine the heat source, thus and ty

Summary of the content on the page No. 19

ge.com Heat Pumps and Energy Savings The Quick Heat Recovery feature is not affected by the Heat Heat Pump Operation — Source Logic shown in the chart above. For more information Zoneline 3900 and 5800 Series about the Quick Heat Recovery Feature, see page 9. The Heat sources: Heat pump, heat pump and simultaneous full heat output of the resistance heater is dependent upon electric resistance heat or electric resistance heat. circuit amperage and the power connection kit used. See Zoneli

Summary of the content on the page No. 20

Application Comments High Wall Mount — For units Use and Care Manual and installation instructions are ® mounted high in the wall, the shipped with Zoneline units. It is important that any air discharge louvers should be conditioning system be properly sized and applied in order at a setting that provides the to achieve the desired temperature and humidity levels with most horizontal air discharge. the space to be conditioned. Air conditioners are designed 50° Recommended installati


Alternative user manuals
# User manual Category Download
1 GE Monogram 3900 Series User manual Air Conditioner 4
2 GE Monogram AEE18 User manual Air Conditioner 4
3 GE Monogram 5800 Series User manual Air Conditioner 2
4 Sony SU-PW2 User manual Air Conditioner 12
5 Sony CV-P12PX User manual Air Conditioner 3
6 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
7 Sony VGN-BX500 User manual Air Conditioner 1
8 Philips 190S5 User manual Air Conditioner 21
9 Philips Comfort-Cire AMC 45 User manual Air Conditioner 7
10 Philips Comfort-Cire AMC 30 User manual Air Conditioner 2
11 Philips CS-E15DB4EW User manual Air Conditioner 4
12 Philips GOGEAR SA3425 User manual Air Conditioner 1
13 Philips 3160 User manual Air Conditioner 7
14 Philips Comfort-Cire AMW User manual Air Conditioner 3
15 Philips Comfort-Cire AMC 25 User manual Air Conditioner 2