GarrettCom P80C user manual

User manual for the device GarrettCom P80C

Device: GarrettCom P80C
Category: Switch
Manufacturer: GarrettCom
Size: 0.2 MB
Added : 9/28/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for GarrettCom P80C. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with GarrettCom P80C.

For your convenience

If looking through the GarrettCom P80C user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual GarrettCom P80C on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual GarrettCom P80C to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
GarrettCom P80C User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual GarrettCom P80C but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to GarrettCom P80C. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


















Magnum P80F & P80C
Corporate Headquarters


Personal Switches
GarrettCom, Inc.

47823 Westinghouse Dr.
Fremont, CA 94539

Phone (510) 438-9071
Fax (510) 438-9072
Website: http://www.GarrettCom.com

email support@garrettcom.com






Installation and User Guide


www .. GarrettCom com
www .. GarrettCom com

Summary of the content on the page No. 2

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) Magnum™ P80F & P80C Personal Switches Installation and User Guide Part #: 84-00079, (Rev B 4/01) Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom, Magnum and Personal Switch are trademarks and Personal Switch is a registered trademark of GarrettCom, Inc. Impor

Summary of the content on the page No. 3

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.com Federal Communications Commission Radio Frequency Interference Statement This equipment generate

Summary of the content on the page No. 4

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) The Magnum Line ETHERNET CONNECTIVITY PRODUCTS "DESIGNED AND MANUFACTURED IN THE USA" OVERVIEW GarrettCom, Inc.offers the premium-quality Magnum™ line of Ethernet LAN connectivity products with industry-standard functionality and built-in fiber configurability. Magnum products are designed for use in demanding Carrier Class, Industrial Grade and OEM applications where reliability is a primary

Summary of the content on the page No. 5

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) TABLE OF CONTENTS PAGE 1.0 SPECIFICATIONS ........................................................................................2 1.1 Technical Specifications..................................................................................... 2 1.2 Ordering Information..............................

Summary of the content on the page No. 6

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) 1.0 SPECIFICATIONS 1.1 Technical Specifications Ports Performance When a port is operating at 100Mbps: Data Rate: 100Mbps When a port is operating at 10 Mbps: Data Rate: 10 Mbps Network Standards 100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for

Summary of the content on the page No. 7

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) External -48VDC Power Supply (Optional) Power Input Voltage: 36 to 70 VDC (auto ranging), “-, GND, +” Power Consumption: 8 watts typical, 10 watts max. Network Cable Connectors - for eight RJ-45 shielded female ports and 1 fiber port 100Mbps: Category 5 UTP/STP, fiber (50/125, 62.5/125, 9/125 micron) 10 Mbps: Category 3, 4, 5 UTP (Note: auto-sensing does not sense cable type) Maximum Load pe

Summary of the content on the page No. 8

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) 1.2 Ordering Information Magnum P80F, 10/100 Personal Switch with a 100Mb Fiber Port Magnum P80F-MSC-d, or -i: 8-port Personal Switch with one 100Mbps switched fiber port (multi-mode SC-type connector), and seven “N-way” half- or full-duplex switched RJ-45 10/100 auto-negotiating ports. Includes store-and-forward switching that filters and forwards data moving between the port

Summary of the content on the page No. 9

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) 2.0 INTRODUCTION 2.1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included. This package should contain: 1 Magnum P80F Personal

Summary of the content on the page No. 10

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) negotiating ports. For half- or full duplex selection on the P80F, and Full-fixed and Auto- negotiation selection on the P80, see sections 4.3 and 4.4. The Magnum P80 & P80F Personal Switches provide the switching speed and the reliability to smoothly support multiple workgroups at 100Mbps or 10 Mbps speed. The optional fiber port is normally configured and tested with the Magnum P80F u

Summary of the content on the page No. 11

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) port. Port # 2SW always supports fiber ports only and the RJ-45 connector is inoperative at all times. LEDs to indicate operating status of all ports are mounted on the top. There are power (PWR) and ERROR (self-test at power up failed) indicators for the unit. For each port, there are Link and Activity (LINK/ACT) LEDs indicating traffic, and speed (ON for 100Mbps), and full/half (F/H) duplex

Summary of the content on the page No. 12

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) When the up-link port is used to cascade two P80-series Personal Switches, the auto-sensing feature will cause the connecting link to operate at 100Mbps speed and full-duplex mode. 2.4 Fiber port, ST or SC Connector for Model P80F Tx Rx Tx Rx UPLINK UPLINK FH = X = X H F H F 100Mbps Fiber port, ST-type mm or SC type (single-mode or multi-mode) Th

Summary of the content on the page No. 13

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) 2.5 Frame Buffering and Latency The Magnum P80 & P80F are store-and-forward switches. Each frame (or packet) is loaded into the Switch’s memory and inspected before forwarding can occur. This technique ensures that all forwarded frames are of a valid length and have the correct CRC, i.e., are good packets. This eliminates the propagation of bad packets, enabling all of the available bandwid

Summary of the content on the page No. 14

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) processing resumes. This flow-control sequence occurs in a small fraction of a second and is transparent to an observer. See Section 4.6 for additional details. Another feature implemented in Magnum P80 & P80F Personal Switches is a collision-based flow-control mechanism (when operating at half-duplex only). When the Switch detects that its free buffer queue space is low, the Switch preven

Summary of the content on the page No. 15

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) Up-Link on port # 1 for a high speed “copper” connection An up-link switch is built in for port # 1. The F/H 10/100 switched RJ-45 port # 1 can support a local server, a power user, another hub or switch cascaded, or a switched “stack” connection to another P80F or P80C for expansion. Installation is “Plug and Play”, operation is transparent to software The Magnum P80F & P80C oper

Summary of the content on the page No. 16

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) 5V, 2Amps Magnum P80 Personal Switch Link/Act Power Speed Error F/H GARRET PORTS 1 2 3 4 5 6 7 8 UPLINK Tx Rx 2 3 4 5 6 7 8 UPLINK 1SW = X F H 2SW 100Mbps fiber Print Server 1

Summary of the content on the page No. 17

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) 5VDC, Magnum P80 Personal Powe Link/Act Speed Erro F/ GARRET PORTS 1 2 3 4 5 6 7 UPLINK Tx Rx UPLINK 1SW 3 4 5 6 7 = FF A 2SW 12V, 1.5Amps Magnum DS80C Dual Personal Hub Powe Link/Ac Spee Erro F/

Summary of the content on the page No. 18

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) 3.0 INSTALLATION This chapter provides instructions for installing Magnum P80-series units. 3.1 Locating Magnum P80F & P80C 10/00Mb Personal Switch The location of a Magnum P80F & P80C Personal Switch is dependent on the physical layout of the network. Typically the switch is located in a workplace site. The compact size of the unit allows it to be conveniently placed in an office, classro

Summary of the content on the page No. 19

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) metal screws for each bracket and attaching to the Magnum P80F and P80C through the round hole of the bracket. A user-supplied screw attaches the bracket to the mounting surface. It is recommended to use appropriate # 4 screws for attaching mounting bracket to wall (e.g wood screw, self-tapping screw, machine screw). It is also recommended that the brackets be attached to two opposite corners o

Summary of the content on the page No. 20

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03) 1. Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded, either unshielded or shielded cables and wiring may be used. 2. Connect the other end of the cable to the corresponding device. 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illumin


Alternative user manuals
# User manual Category Download
1 GarrettCom 1024 User manual Switch 1
2 GarrettCom 4K-Series User manual Switch 4
3 GarrettCom 14E User manual Switch 0
4 GarrettCom 500-Series User manual Switch 1
5 GarrettCom 4K16 User manual Switch 2
6 GarrettCom 1016 User manual Switch 0
7 GarrettCom 6K32 User manual Switch 2
8 GarrettCom 6K25 User manual Switch 2
9 GarrettCom 6K16V User manual Switch 1
10 GarrettCom 6K32TRC User manual Switch 3
11 GarrettCom 6K32T User manual Switch 14
12 GarrettCom 6K8 User manual Switch 1
13 GarrettCom 8000X User manual Switch 2
14 GarrettCom CS14 User manual Switch 1
15 GarrettCom DS 880 User manual Switch 1
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4