GarrettCom - Garrett CommunicationsMagnum 6KQ user manual

User manual for the device GarrettCom - Garrett CommunicationsMagnum 6KQ

Device: GarrettCom - Garrett CommunicationsMagnum 6KQ
Category: Switch
Manufacturer: GarrettCom
Size: 0.63 MB
Added : 9/28/2014
Number of pages: 56
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for GarrettCom - Garrett CommunicationsMagnum 6KQ. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with GarrettCom - Garrett CommunicationsMagnum 6KQ.

For your convenience

If looking through the GarrettCom - Garrett CommunicationsMagnum 6KQ user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual GarrettCom - Garrett CommunicationsMagnum 6KQ on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual GarrettCom - Garrett CommunicationsMagnum 6KQ to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
GarrettCom - Garrett CommunicationsMagnum 6KQ User manual - Online PDF
Advertisement
« Page 1 of 56 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual GarrettCom - Garrett CommunicationsMagnum 6KQ but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to GarrettCom - Garrett CommunicationsMagnum 6KQ. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1












Corporate Headquarters




GarrettCom, Inc.

47823 Westinghouse Dr.
Fremont, CA 94539-7437

Phone (510) 438-9071
Fax (510) 438-9072
Magnum 6KQ
Website: http://www.GarrettCom.com

Managed Field Switch
email support@garrettcom.com














Hardware



Installation and User Guide


www .. GarrettCom com www .. GarrettCom com

i

Summary of the content on the page No. 2

Magnum 6KQ Managed Field Switch Installation & User Guide 04/07) Magnum™ 6KQ Managed Field Switch Hardware Installation and User Guide Part #: 84-00180Z (Rev. A) Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc. Important: The Magnum

Summary of the content on the page No. 3

Magnum 6KQ Managed Field Switch Installation & User Guide 04/07) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.com Federal Communications Commission Radio Frequency Interference Statement Radio Frequency Interference Statement This

Summary of the content on the page No. 4

Magnum 6KQ Managed Field Switch Installation & User Guide 04/07) Table of Contents.............................................................................. Page 1.0 SPECIFICATIONS ............................................................................... 1 1.1 Technical Specifications ...................................................................... 1 1.2 Ordering Information..........................................................................

Summary of the content on the page No. 5

Magnum 6KQ Managed Field Switch Installation & User Guide 04/07) 5.2.2. 6KQF-2MSC Fiber connector .................................................... 37 5.2.3 6KQF-2SSCL FX-SC-type, Sgl.M ........................................... 37 5.2.4 6KQ3-RJMSC “COMBO” connector....................................... 38 5.2.5 6KQ4-MT MTRJ Small-Form-factor ......................................... 38 5.2.6 6KQ4-RJMT, “COMBO” multi-mode FX , MTRJ Small-FF ... 39 5.2.7 6K

Summary of the content on the page No. 6

Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) THE MAGNUM LINE Industrial networking products "Designed and Manufactured in the USA" Overview GARRETTCOM, INC. OFFERS THE PREMIUM-QUALITY MAGNUM™ LINE OF INDUSTRIAL CONECTIVITY PRODUCTS WITH INDUSTRY-STANDARD FUNCTIONALITY AND BUILT-IN FIBER CONFIGURABILITY. MAGNUM PRODUCTS ARE DESIGNED FOR USE IN DEMANDING INDUSTRIAL GRADE, CARRIER CLASS, POWER UTILITY AND OEM APPLICATIONS WHERE RELIABILITY IS A PRIMARY CONSIDERATION

Summary of the content on the page No. 7

Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 1.0 SPECIFICATIONS 1.1 Technical Specifications Performance Filtering / Forwarding Rate: Ethernet(10Mb):14,880 pps Fast Ethernet(100Mb): 148,800 pps Gigabit Ethernet (1000Mb): 1, 488,000 pps Switching Processing Type: Store and Forward with IEEE 802.3x full- duplex flow -control, non-blocking Data Rate: 10Mbps,100Mbps and 1000Mbps Address Table Capac

Summary of the content on the page No. 8

Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 1000BASE-SX, full-duplex, multi-mode(50µm cable) - 550m 1000BASE-LX, full-duplex, single-mode(62.5µm cable) -5Km Fiber Multi-mode connector types supported: Fiber Port, ST-type (twist-lock):Fiber multi-mode, 10Mb 10BASE-FL Fiber Port, MTRJ-type (plug-in):SFF Fiber multi-mode100BASE-FX Fiber Port, SC-type (snap-in):Fiber optic multi-mode, 100BASE-FX Fiber Port, ST-type (twist-lock): Fiber

Summary of the content on the page No. 9

Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 12 watts typical (for a small 4 port copper-only model) DC-DUAL POWER SOURCE (OPTIONAL) For DC internal power supplies at –48VDC, 24VDC and 125VDC, with the Dual-Source option (for continuity of operation when either of the DC input sources are interrupted), see Appendices B and C. Dual-Source Terminal Block : “ –A, -B, +A, +B ” 6KQ Mounting: Vertical mounting normal. Suitable for wall or DIN-Rail

Summary of the content on the page No. 10

Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 1.2 Ordering Information Magnum Managed Field Switch (16 ports max) MODEL DESCRIPTION Magnum 6KQ- 24VDC Magnum 6KQ Managed Field Switch, base unit with 24VDC power supply and four 10/100 copper ports. May be configured with a selection of 10/100/1000 fiber and copper port connector types from a family of 6KQ port modules per the 6KQ configuration guide, 16 total ports max. Heavy duty and environmentally

Summary of the content on the page No. 11

Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 6KQF-4MT “4 ports” module, w/four 100Mb mm 2km FX MTRJ’s fiber ports 6KQF-4MLC “4 ports” module, w/four 100Mb mm 2km FX LC’s fiber ports 6KQF-4SLC “4 ports” module, w/four 100Mb Sm, 15km FX LC’s fiber ports 6KQF-2MST “2 ports” module, w/two 100Mb mm, 2km FX ST’s fiber ports 6KQF-2MSC “2 ports” module, w/two 100Mb mm, 2km FX SC’s fiber ports 6KQF-2SSC “2 ports” module, w/two 100Mb Sm, 20km FX SC’s fiber ports 6

Summary of the content on the page No. 12

Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 2.0 Introduction 2.1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included. This package should contain: 1 Magnum 6KQ Managed Field Switch, bas

Summary of the content on the page No. 13

 Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 2.2 Product Description - Magnum 6KQ Field Switch Magnum 6KQ Managed Field Switches provide maximum configurability in their class. The fiber-rich 6KQ can be configured with up to 12 100Mb fiber ports and two Gigabit ports. For 10/100 copper, regular or PoE-equipped 10/100 RJ-45 or 10/100/1000 copper ports may be configured to a maximum or 12 at 10/100 and 2 Gig ports. Magnum 6KQ comes with the best-of-br

Summary of the content on the page No. 14

Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) The 6KQ managed switches also provide PoE options via power – inside PoE modules on one of A, B or C slots and allows the users to select a wide option of combo PoE modules to support 802.3af pd devices. See details for PoE modules in sec 5.2.10. The Power Sourcing Equipment (PSE) is fully compatible with Powered Devices (PD)(e.g wireless access points, IP phones) that comply with the IEEE 802.3af PoE standard

Summary of the content on the page No. 15

Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) Alarm Relay contacts provided on each Magnum 6KQ Switch monitor the hardware and software through traps, providing a record of any losses of power signals and other user- defined software events. See Section 3.5 for details. The wide selections of Quad port (queen size) modules are key to the flexibility and adaptability of Magnum 6KQs. Some of the popular 4 ports modules are described below. For a list of all

Summary of the content on the page No. 16

Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) on the port. A fiber cable must be connected into a SFF port and the Link (LK) indicator for that port must be ON (indicating there is a powered-up device at the other end of the cable) in order for a LK LED to provide valid indications of operating conditions on that port. 2.2.2 Four-Port Copper Module, 6KQ4-RJ45 The 6KQ’s 4-port Copper module, model 6K4-RJ45, provides four 10/100Mb switched 1

Summary of the content on the page No. 17

Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) dependent upon the -48VDC input power to supply the PD power for these RJ-45 (10/100) ports. Each port supplies up to 15watts to power the PoE PD devices. A maximum of 8 PoE ports can be configured in the A and B slots of a 6KQ switch with - 48vdc power input. The PoE modules are also available with mix–n-match fiber modules configured in other 6KQ slots. Please check the Configuration Guide and the ordering inf

Summary of the content on the page No. 18

Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) 2.2.5 Two -Port 10 Mb mm Fiber ST Modules The 2-port @10Mb ST fiber modules behave the same as the 2@100Mb ST fiber modules except for the 10Mb speed. The default setup on the 10Mb fiber module is half-duplex, which allows the Magnum 6KQ Switch to connect to any 10Mb hub or media converter or almost any other device with a 10Mb fiber Ethernet port. The default setting of the 100Mb fiber module is full dup

Summary of the content on the page No. 19

Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) There are three LEDs mounted on each Gigabit port module. The Gigabit fiber has LEDs that indicate F/H (Full/Half duplex), LK (Link status) and ACT (receiving activity) on that port when lit. The copper Gigabit ports come with speeds indicating (10/100/1000Mb) LEDs also. The operation of the Gigabit SFP and 10/100/1000 RJ-45 ports is as described for those port types above. For detailed information about 10Mb

Summary of the content on the page No. 20

Magnum 6KQ Managed Field Switch Installation and User Guide (04/07) load is greatest. When the Magnum 6KQ Switch detects that its free buffer queue space is low, the Switch sends industry standard (full-duplex only) PAUSE packets out to the devices sending it packets to cause “flow control”. This tells the sending devices to temporarily stop sending traffic, which allows the traffic to catch-up without dropping packets. Then, normal packet buffering and processing resumes. Th


Alternative user manuals
# User manual Category Download
1 GarrettCom 1024 User manual Switch 1
2 GarrettCom 4K-Series User manual Switch 4
3 GarrettCom 14E User manual Switch 0
4 GarrettCom 500-Series User manual Switch 1
5 GarrettCom 4K16 User manual Switch 2
6 GarrettCom 1016 User manual Switch 0
7 GarrettCom 6K32 User manual Switch 2
8 GarrettCom 6K25 User manual Switch 2
9 GarrettCom 6K16V User manual Switch 1
10 GarrettCom 6K32TRC User manual Switch 3
11 GarrettCom 6K32T User manual Switch 14
12 GarrettCom 6K8 User manual Switch 1
13 GarrettCom 8000X User manual Switch 2
14 GarrettCom CS14 User manual Switch 1
15 GarrettCom DS 880 User manual Switch 1
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4