Extron electronic sDMS 3200 user manual

User manual for the device Extron electronic sDMS 3200

Device: Extron electronic sDMS 3200
Category: Switch
Manufacturer: Extron electronic
Size: 4.48 MB
Added : 5/24/2013
Number of pages: 25
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Extron electronic sDMS 3200. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Extron electronic sDMS 3200.

For your convenience

If looking through the Extron electronic sDMS 3200 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Extron electronic sDMS 3200 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Extron electronic sDMS 3200 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Extron electronic sDMS 3200 User manual - Online PDF
Advertisement
« Page 1 of 25 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Extron electronic sDMS 3200 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Extron electronic sDMS 3200. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Setup Guide
Matrix Switchers
DMS 1600, DMS 2000,
DMS 3200, DMS 3600
Configurable Digital Video Matrix Switchers

68-1829-50 Rev. C
09 13

Summary of the content on the page No. 2

Safety Instructions FCC Class A Notice Safety Instructions • English Инструкция по технике This equipment has been tested and found to comply with the limits for a безопасности • Русский WARNING: This symbol, , when used on the product, is intended Class A digital device, pursuant to part 15 of the FCC rules. The Class A to alert the user of the presence of uninsulated dangerous voltage ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан within the product’s enclosure that may present a risk of e

Summary of the content on the page No. 3

Software Commands Contents Commands are written in the fonts shown here: ^AR Merge Scene,,Op1 scene 1,1 ^B 51 ^W^C [01] R 0004 00300 00400 00800 00600 [02] 35 [17] [03] E Y! *Y1&* Y2)* Y2#* Y2! CE} Introduction ..................................... 1 Remote Control .............................. 13 About this Guide ........................... 1 Selected SIS Commands ............ 13 NOTE: For commands and examples of computer or device responses mentioned in this guide, the character “0” is u

Summary of the content on the page No. 4

Introduction WARNING: Risk of serious physical injury — The DMS fiber optic I/O boards output continuous invisible light, which may be harmful to the eyes; use with caution. • Do not look into the fiber optic cable connectors or into the fiber optic cables themselves. • Plug the attached dust caps into the optical transceivers when the fiber cable is unplugged. This section gives an overview of this guide and the DMS 1600, DMS 2000, DMS 3200, and DMS 3600 and describes their features. Top

Summary of the content on the page No. 5

About the DMS Matrix Switchers Configurability The DMS 1600, DMS 2000, DMS 3200, and DMS 3600 (see figure 1) The DMS matrix switchers are assembled from I/O boards. are configurable matrix switchers that distribute DVI signals and DFX • The DMS 1600 can include up to four I/O boards. transmitter and receiver outputs and inputs. I/O boards route signals • The DMS 2000 can include up to five I/O boards. that are compatible with all Extron DVI video product lines and the fiber optic outputs an

Summary of the content on the page No. 6

Installation This section describes installation of the DMS matrix switchers, including connections and features. Topics that are covered include: • Rear Panel • Front Panel Rear Panel I/O Board Configuration Overview See figure 2. Each I/O board is identified by the input and output connector numbers supported by the board position. The input and output numbers on the boards are identified as locations A through D. Location A Location A Input Output Input 2 Input 3 Input 4 Output 1 Output

Summary of the content on the page No. 7

10 1 1 2 10 1 1 2 DVI-D INPUTS DVI-D OUTPUTS A B C D A B C D DVI-D INPUTS DVI-D OUTPUTS A B C D A B C D DMS 44 DVI ANAHEIM, CA AB AB CD CD AB AB CD CD FAN ASSIMBLY DMS 44 DVI DVI-D INPUTS DVI-D OUTPUTS TMDS TMDS A B C D A B C D FIBER FIBER DMS FIBER 44 INPUTS OUTPUTS AB CD DMS 44 DVI DVI-D INPUTS DVI-D OUTPUTS TMDS A B C D A B C D FIBER DMS FIBER 44 INPUTS AB CD DMS 44 DVI DVI-D INPUTS DVI-D OUTPUTS TMDS A B C D A B C D FIBER DMS FIBER 44 INPUTS DMS 44 DVI REDUND REDUNDANT ANT AB CD AB CD

Summary of the content on the page No. 8

Front Panel Remote port — If desired, connect a control system or computer to e the rear panel Remote RS-232/RS-422 port. CONTROL Pin RS-232 Function RS-422 Function CONFIG ENTER PRESET VIEW ESC 1 — Not used — Not used CONTROL VIEW ESC 2 Tx Transmit Tx– Transmit (–) PRIMARY CONFIG ENTER PRESET 5 REDUNDANT 1 3 Rx Receive Rx– Receive (–) POWER POWER SUPPLY 4 — Not used — Not used DMS 1600 DMS 2000 5 Gnd Ground Gnd Ground TMDS DIGITAL MATRIX SWITCHER TMDS DIGITAL MATRIX SWITCHER 6 — Not used —

Summary of the content on the page No. 9

Front Panel Operations This section describes simple DMS matrix switcher operation from the front panel. Topics that are covered include: • Creating a Tie • Viewing Ties (and Muting Outputs) • Saving or Recalling a Preset • Locking Out the Front Panel (Executive Mode) Creating a Tie A "tie" is an input-to-output connection. A "set of ties" is an input tied to two or more outputs. (An output can never be tied to more than one input.) A "configuration" is one or more ties, one or more sets of

Summary of the content on the page No. 10

3. Press an output button. The buttons for the tied input and all tied Remote Control outputs light. 4. Press the View button again to exit View mode. All input and output buttons return to an unlit state. Saving or Recalling a Preset This section describes using the remote control features of the DMS matrix switchers to control the devices. Topics that are covered The DMS switchers have 32 global memory presets. include: 1. Save a preset — Press and hold the Preset button until it flashes

Summary of the content on the page No. 11

Number of connections A switcher can have up to 200 simultaneous TCP connections, including all HTTP sockets and Telnet connections. When the connection limit is reached, the switcher accepts no new connections until some have been closed. No error message or indication is given that the connection limit has been reached. To maximize the performance of your switcher, keep the number of connections low and close unnecessary open sockets. Establishing a USB Port Connection A standard USB ca

Summary of the content on the page No. 12

• • • • • • • • • • • • • • • • DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 15 Command and Response Table for SIS Commands Command ASCII Command Response Additional Description (Host to Unit) (Unit to Host) NOTES: Commands can be entered back-to-back in a string, with no spaces. For example: 1*1!02*02&003*003%. The matrix switchers support 1-, 2-, and 3-digit numeric entries (1*1!, 02*02&, or 003*003%). Create ties NOTES: The ! tie command, the & tie command, and the % tie comm

Summary of the content on the page No. 13

16 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 17 Command ASCII Command Response Additional Description (Host to Unit) (Unit to Host) EDID NOTE: In the commands below, the EDID data can come from either an active output or be set to a specified value. E X! X# } X! X#] X! Assign EDID data to an input A * EDID EdidA * = Input number Assign EDID data to all inputs E X# } X#] A* *EDID EdidA0* E X# } X#] Save output #1 EDID data to

Summary of the content on the page No. 14

• • 18 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control 19 Command ASCII Command Response Additional Description (Host to Unit) (Unit to Host) Channel mute commands X@ Channel mute Mute output (no signal is output). X@*1B VmtX@*1] X@ Channel unmute X@*0B VmtX@*0] Unmute output (signal is output). Read channel mute 1 = mute on, 0 = mute off. X@B X$] Global channel mute 1*B Mute all outputs. Vmt1] Global channel unmute 0*B Unmute a

Summary of the content on the page No. 15

20 DMS 1600, DMS 2000, DMS 3200, DMS 3600 • Remote Control Command and Response Table for IP-Specific SIS Commands Additional Description Command ASCII Command Response (host to unit) (unit to host) IP and serial port setup Set IP address Default: 192.168.254.254 EX1!CI} IpiX1!] Read IP address ECI} X1!] Set subnet mask EX1!CS} IpsX1!] Default: 255.255.0.0 Read subnet mask ECS} X1!] Set gateway IP address Default: 0.0.0.0 EX1!CG} IpgX1!] Read gateway IP address ECG} X1!] Set DHCP on or off EX

Summary of the content on the page No. 16

Installing and Starting the Control Program ® Another way to operate the switcher is via the Windows -based Matrix Switchers Control Program. This program is contained on the Extron Software Products DVD (included with the switcher) or on the website. Run this program on a PC connected to a serial port (item on page 8), e Ethernet port (item on page 8), or USB port (item on page 9) on the f a switcher. The program must be installed on a Windows-based computer and cannot be run from the

Summary of the content on the page No. 17

4. Follow the on-screen instructions. The installation program creates a 2. On the next page that appears, select the Install the software C:\Program Files\Extron\Matrix_Switchers directory and an “Extron automatically radio button and click Next. Follow the on-screen Electronics\Matrix Switchers” group folder. It installs the following instructions. The wizard assigns the driver necessary to access the four programs: switcher to the connected Configuration (USB) port (this may take a few

Summary of the content on the page No. 18

4. If you selected IP [LAN] in step 2, the IP Connection window Accessing the HTML Pages appears. Another way to configure and operate the switcher is via its factory-installed HTML pages, which are always available and cannot be erased or overwritten. The HTML pages that are pre-loaded on the switcher are accessible through its LAN port, connected via a LAN or ® ® WAN, using a web browser such as Microsoft Internet Explorer (see item on page 8, for connection information.) f Configurin

Summary of the content on the page No. 19

5. Execute a ping command by entering ping followed by a space and 4. Press the keyboard key. The switcher checks whether it is the new IP address at the command prompt. For example: password-protected. ping 10.13.197.7 If the switcher is not password-protected, it checks and downloads the HTML start-up page. The switcher is ready for C:\>ping 10.13.197.7 operation via HTML remote control. Pinging 10.13.197.7 with 32 bytes of data: If the switcher is password-protected, it downloads

Summary of the content on the page No. 20

Maintenance and Modifications This section describes repairing and reconfiguring the DMS matrix switchers by replacing components. Topics that are covered include: • Removing and Installing an I/O Board or Blank Panel • Removing and Installing a Power Supply Module (DMS 1600 and DMS 3600) • Removing and Installing a Fan (DMS 1600 and DMS 3600) Removing and Installing an I/O Board or Blank Panel NOTES: • For proper cooling and air flow, boards or blank panels should be installed in all loca


Alternative user manuals
# User manual Category Download
1 Extron electronic 3000 User manual Switch 1
2 Extron electronic 3200 Series User manual Switch 3
3 Extron electronic 3000B User manual Switch 0
4 Extron electronic 26-238-07 User manual Switch 3
5 Extron electronic 60-442-01 User manual Switch 0
6 Extron electronic 14400 User manual Switch 1
7 Extron electronic 426-01 User manual Switch 1
8 Extron electronic 60-442-11 User manual Switch 2
9 Extron electronic 450 Plus User manual Switch 2
10 Extron electronic 60-426-01 User manual Switch 0
11 Extron electronic 5cr Plus User manual Switch 2
12 Extron electronic 3200s User manual Switch 6
13 Extron electronic 60-442-02 User manual Switch 1
14 Extron electronic 60-728-01 User manual Switch 1
15 Extron electronic 64 Series User manual Switch 1
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4