Enterasys Networks Enterasys Vertical Horizon VH-2402S user manual

User manual for the device Enterasys Networks Enterasys Vertical Horizon VH-2402S

Device: Enterasys Networks Enterasys Vertical Horizon VH-2402S
Category: Switch
Manufacturer: Enterasys Networks
Size: 1.23 MB
Added : 5/3/2014
Number of pages: 110
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Enterasys Networks Enterasys Vertical Horizon VH-2402S. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Enterasys Networks Enterasys Vertical Horizon VH-2402S.

For your convenience

If looking through the Enterasys Networks Enterasys Vertical Horizon VH-2402S user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Enterasys Networks Enterasys Vertical Horizon VH-2402S on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Enterasys Networks Enterasys Vertical Horizon VH-2402S to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Enterasys Networks Enterasys Vertical Horizon VH-2402S User manual - Online PDF
Advertisement
« Page 1 of 110 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Enterasys Networks Enterasys Vertical Horizon VH-2402S but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Enterasys Networks Enterasys Vertical Horizon VH-2402S. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

VERTICAL HORIZON
VH-2402S
FAST ETHERNET SWITCH
MANAGEMENT GUIDE
9033645-01

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Notice Only qualified personnel should perform installation procedures. NOTICE Enterasys Networks reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Enterasys Networks to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL ENTERASYS NETWORKS BE LIABLE FOR ANY INCIDENTAL

Summary of the content on the page No. 4

Notice ii 9033645-01

Summary of the content on the page No. 5

TABLE OF CONTENTS 1. MANAGEMENT OVERVIEW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Required Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Console Port (Out-of-Band) Connections . . . . . . . . . . . . . . . . . . . . 1 Remote Management via the Console Port. . . . . . . . . . . . . . . . . . . 2 In-Band Connections .

Summary of the content on the page No. 6

Displaying the Unicast Address Table . . . . . . . . . . . . . . . . . . . . . 62 Displaying the IP Multicast Registration Table . . . . . . . . . . . . . . . 63 Configuring Static Unicast Addresses. . . . . . . . . . . . . . . . . . . . . . 64 Resetting the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Logging Off the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 3. CONFIGURING & MONITORING THE SWITCH . . . . . . . . .

Summary of the content on the page No. 7

Remapping Network Topology . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 APPENDIX B. VIRTUAL LANS (VLANS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 VLANs and Frame Tagging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 VH-2402S VLAN Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Assigning Ports to VLANs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Forwarding Tagged/Untagged Frames . . . . . .

Summary of the content on the page No. 8

vi Table of Contents VH-2402S

Summary of the content on the page No. 9

1. MANAGEMENT OVERVIEW Configuration Options For advanced management capability, the VH-SMGMT Vertical Horizon Management Module provides a menu-driven system configuration program. This program can be accessed by a direct or modem connection to the serial port on the Management Module (out-of-band), or by a Telnet connection over the network (in-band). The Management Module is based on SNMP (Simple Network Management Protocol). This SNMP agent permits a switch stack to be managed from any

Summary of the content on the page No. 10

When attaching to a PC, set terminal emulation type to VT100, specify the port used by your PC (i.e., COM 1~4), and then set communications to 8 data bits, 1 stop bit, no parity, and 19200 bps (for initial configuration). Also be sure to set flow control to “none.” (Refer to “Configuring the Serial Port” on page 19 for a complete description of configuration options.) Remote Management via the Console Port Configure the Switch Site Connect the Management Module’s DB9 serial port to the modem

Summary of the content on the page No. 11

In-Band Network Connection The on-board configuration program can be accessed using Telnet from any computer attached to the network. The switch and stack can also be managed by any computer using a Web browser (Internet Explorer 4.0 or above, or Netscape Navigator 4.0 or above), or from a network computer using network management software. 9033645-01 Management Overview 3

Summary of the content on the page No. 12

4 Management Overview VH-2402S

Summary of the content on the page No. 13

2. VH-2402S USER INTERFACE Overview Access is gained to the console menus by connecting a terminal to the console port (with a direct cable connection or over modems), or using Telnet to access the Management Module over the network. These menus allow you to reconfigure the switch, as well as to monitor the status and performance of the switch or the attached stack. The menus have a layout similar to the sample Main Menu shown in Figure 2-1. The information is divided into the following pa

Summary of the content on the page No. 14

User Access Once a direct connection to the serial port or a Telnet connection is established, the login screen for the on-board configuration program . You may need to press Enter a few times to display the screen. appears The default user names are “admin” and “guest,” with no passwords. The administrator has Read/Write access, which allows you to read and modify switch information. The guest has Read Only access to the management program, which allows you to view switch information, but

Summary of the content on the page No. 15

Factory Defaults Table 2-1 lists the default settings for switch configuration parameters. Each parameter can be changed via the console menus or Telnet. Table 2-1. Factory Default Settings Parameter Default Value Multicast Filtering GMRP Disabled IGMP Multicast Filtering Disabled Port Configuration Flow Control Disabled Speed and Duplex Auto Admin Enabled Broadcast Storm Control Enabled - 500 pps Port Priority Default Ingress User Priority 0 Spanning Tree Algorithm Active Aging Time 300 Bri

Summary of the content on the page No. 16

Parameter Default Value Virtual LANs Acceptable VLAN Frame Type All Configurable PVID Tagging Yes GVRP Disabled Untagged VLAN Group Assignment 1 VLAN Ingress Filtering False VLAN Learning SVL 8 VH-2402S User Interface VH-2402S

Summary of the content on the page No. 17

Main Menu The Main Menu is the first screen seen after successfully logging into the system. Figure 2-2 shows the Main Menu and the accompanying table . describes the Main Menu Vertical Horizon Local Management -- VH-2402S Main Menu System Information Menu... Management Setup Menu... Device Control Menu... Network Monitor Menu... System Restart Menu... Exit Use or arrow keys to move. to select. Figure 2-2. Main Menu Selection Description System Information Menu System Informati

Summary of the content on the page No. 18

Selection Description Device Control Menu Port Configuration Enables any port, enables/disables flow control, and sets communication mode to auto-negotiation, full duplex or half duplex. Port Information Displays operational status, including link state, flow control method, and duplex mode. Spanning Tree Enables Spanning Tree Algorithm; also sets parameters for Configuration hello time, maximum message age, switch priority, and forward delay; as well as port priority and path cost. Spanni

Summary of the content on the page No. 19

Selection Description IP Multicast Displays all the multicast groups active on this switch, Registration Table including multicast IP addresses and corresponding VLAN IDs. Static Unicast Address Used to manually configure host MAC addresses in the Table Configuration unicast table. System Restart Restarts system with options to use POST, or to retain factory defaults, IP settings, or user authentication settings. Exit Exits the configuration program. System Information Menu Use the System

Summary of the content on the page No. 20

Displaying System Information Use the System Information screen to display descriptive information about the switch, or for quick system identification as shown in the following figure and table. Vertical Horizon Local Management -- VH-2402S System Information System Description : Vertical Horizon VH-2402S System Object ID : 1.3.6.1.4.1.52.3.9.1.10.7 System Up Time : 48067 (0 day, 1 hr, 2min, 34 sec) System Name : DEFAULT SYSTEM NAME System Contact : DEFAULT SYSTEM CONTACT Syste


Alternative user manuals
# User manual Category Download
1 Enterasys Networks 2H252-25R User manual Switch 7
2 Enterasys Networks 2S4082-25-SYS User manual Switch 2
3 Enterasys Networks 5H1XX User manual Switch 4
4 Enterasys Networks 6E2xx User manual Switch 0
5 Enterasys Networks 2G4072-52 User manual Switch 16
6 Enterasys Networks 6H2xx User manual Switch 0
7 Enterasys Networks BL-89520ENT User manual Switch 0
8 Enterasys Networks BL-89710ENT User manual Switch 0
9 Enterasys Networks 6H3xx User manual Switch 1
10 Enterasys Networks 5G1XX User manual Switch 0
11 Enterasys Networks 700 User manual Switch 0
12 Enterasys Networks BL-89420ENT User manual Switch 0
13 Enterasys Networks BL-89620ENT User manual Switch 0
14 Enterasys Networks 6G3xx User manual Switch 0
15 Enterasys Networks C1H124-24 User manual Switch 0
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4