Emerson E-DESIGN 150-400A user manual

User manual for the device Emerson E-DESIGN 150-400A

Device: Emerson E-DESIGN 150-400A
Category: Switch
Manufacturer: Emerson
Size: 1.02 MB
Added : 1/15/2014
Number of pages: 10
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson E-DESIGN 150-400A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson E-DESIGN 150-400A.

For your convenience

If looking through the Emerson E-DESIGN 150-400A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson E-DESIGN 150-400A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson E-DESIGN 150-400A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson E-DESIGN 150-400A User manual - Online PDF
Advertisement
« Page 1 of 10 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson E-DESIGN 150-400A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson E-DESIGN 150-400A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

7000 Series ACTS
Operator’s
Automatic Closed–Transition Transfer Switches
Manual
E–design 150–400A, F–design 600–800A,
G–design 1000–4000A, F–design 3000–4000A,
Refer to the outline and wiringdrawings provided
with your 7000 Series ACTS for allinstallation and
DANGER is used in this manual to warn of high
connection details and accessories.
voltages capable of causing shock, burns, or death.
Refer to Group 5 Controller User’s Guide
381333–126 for ATS status display messages, time
delays, pickup

Summary of the content on the page No. 2

Catalog Number Identification Typical 7000 Series catalog no. for E–design switched neutral, 3 pole, 400 amp, 480 V, ACTS in Type 1 enclosure: E 7ACTS C 3 400 N 5 C design prefix letter Neutral PhasePoles Amperes Voltage Controller Enclosure A –solid 2–singleØ A 115 5–standard C –type1 150 1000 J 400 B–switched 260 3–threeØ 1200 B 120 K 415 5X–if F–type3R accessories 400 G–type4 C –overlapping C 208 L 440 1600 ordered 600 L –type12 2000 blank–none D 220 M 460 800 blank–opentype 3000 E 230 N 480

Summary of the content on the page No. 3

SECTION1 INSTALLATION ASCO Series 7000 AutomaticClosed–Transition Transfer Switches are factory wired and tested. Field installation simply requires mountingand connection of service De–energize the conductors before making any line orauxiliary circuitry connections. Be sure cables, and auxiliary controlcircuits (if required). thatNormal and Emergency line connections Remove the Shipping Skid are in proper phase rotation. Place engine gen- erator starting control in the OFFposition. Forlargeswit

Summary of the content on the page No. 4

INSTALLATION (continued) TightenboltedjointstothetorquespecifiedinTableA. Engine Starting Contacts The engine controlcontact connections(ifused)are located onthe transferswitch. Connect signalwiresto The reliablility of the connection depends appropriateterminalsasspecifiedinTableBandshown onhowcleanand howtightthejointis. inFigure 1–1. Table B. Engine start connections Table A. Tightening torque values for bolted joints (Grade 5 hardware) When normal Terminals on source fails transferswitch Bol

Summary of the content on the page No. 5

INSTALLATION (continued) handle shafts handle handle Figure 1-2. Figure 1-3. Figure 1-4 150 – 400 A (3 pole) 600 & 800 A (& 4 pole 400 A) 3000 & 4000 A E–design switches F–design switches F–design transfer switches 1000 through 4000 amp. G–design SeeFigure1-5. 1–ManualOperation Installthe hub(with pin) onto the shaft and insert the Adetachablemanualoperatorhandleisprovidedonthe manualfirmlyintothesideholeinthehub. Pushin Transfer Switchesformaintenancepurposesonly. or pullout hubto engage opposi

Summary of the content on the page No. 6

INSTALLATION (continued) GREEN RED RED RED RED observe these lights GREEN RED Figure 1-6. Standard controls and indicators. Close the normal source circuit breaker. The Transfer Switch 2 --- Voltage Checks 1 Connected To Normal and the First check nameplate on transfer switch;rated voltage Normal Source Accepted lights should come on. mustbethesameasnormalandemergencylinevoltages. Use an accurate voltmeter to check phase to phase and Verify thatthe feeders have been 2 phase to neutral voltages p

Summary of the content on the page No. 7

INSTALLATION (continued) GREEN RED RED RED RED observe operate these lights this switch GREEN RED Figure 1-7. Standard controls and indicators. 3 --- ElectricalOperation The Transfer Switch Connected To Normal and Normal Source 1 Thisprocedure willcheck the electricaloperationof the Accepted lights should be on. AutomaticClosed–TransitionTransferSwitch. See Figure 1---7. Turn and hold Transfer Control switch clockwise to Transfer Test until the engine starts and runs 2 Besureto closetheenclosure

Summary of the content on the page No. 8

SECTION2 TESTING&SERVICE TRANSFERTEST DISCONNECTINGTHE CONTROLLER Operate the 7000 Series ACTS at least once a month The harness disconnect plugs are furnished for repair by followingthe five–step Electrical Operation purposes only and should not have to be unplugged. Transfer Testprocedure on page 1–5. If the controller must be isolated, followthese steps: Disconnecting the Plugs PREVENTIVEMAINTENANCE Reasonable care inpreventive maintenance willinsure high reliability and longlife for the 7000

Summary of the content on the page No. 9

TESTING&SERVICE (continued) 2. Usethemaintenancehandletomanuallyoperatethe MANUALLOADTRANSFER transfer switch to the opposite source. First open the Thisprocedure willmanually transferthe loadif the closed contacts, then close the other contacts. Do not controller is disconnected. leave both closed.See Manual Operation on page 1–3. 3. Thenremovethemaintenancehandle. Seepage1–3. Do notmanually operate the transferswitch until bothpowersources are disconnected (all conductors deenergized). Verify

Summary of the content on the page No. 10

INDEX A I R alarmreset, 1–5, 2–2 inspection, 2–1 ratinglabel, cover auxiliarycircuits,1–2 installation, 1–1 replacementparts,2–1 L C S labels, cable settings enginestartcontacts, 1–2 lugs, 1–2 see Controller User’s Guide rating, cover preparation,1–2 lights, 1–4, 1–5 catalognumber, inside cover T lubrication,2–1 cleaning, 2–1 test, functional, 1–2, 1–3, 1–4, 1–5 closedtransitionbypass, 1–5, 2–2 M timedelays, 2–1 see Controller User’s Guide connections maintenancehandle, 1–3 line, 1–1 TransferCon


Alternative user manuals
# User manual Category Download
1 Emerson 5081-T User manual Switch 38
2 Emerson ASCO 300 Series User manual Switch 747
3 Emerson ASCO 7000 User manual Switch 91
4 Emerson 7000 User manual Switch 58
5 Emerson ASCO 185 User manual Switch 45
6 Emerson 7ADTB User manual Switch 3
7 Emerson 185 User manual Switch 7
8 Emerson B-294 HD User manual Switch 0
9 Emerson Autochangeover Controllers AC8 User manual Switch 7
10 Emerson 214A401 User manual Switch 0
11 Emerson 214A400 User manual Switch 3
12 Emerson 214A404 User manual Switch 0
13 Emerson 260 User manual Switch 0
14 Emerson 300 User manual Switch 1
15 Emerson 386 User manual Switch 0
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4