Emerson ADTS user manual

User manual for the device Emerson ADTS

Device: Emerson ADTS
Category: Switch
Manufacturer: Emerson
Size: 0.82 MB
Added : 1/15/2014
Number of pages: 13
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson ADTS. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson ADTS.

For your convenience

If looking through the Emerson ADTS user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson ADTS on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson ADTS to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson ADTS User manual - Online PDF
Advertisement
« Page 1 of 13 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson ADTS but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson ADTS. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Operator’s
4000 Series ADTS
Automatic Delayed–Transition Transfer Switches
Manual
J–design 150–600A, H–design 800–1200A,
G–design 1600–3000A, F–design 4000A
Refer to the outline and wiring drawings provided
with your 4000 Series ADTS for all installation and
DANGER is used in this manual to warn of high
connectiondetailsandaccessories.
voltages capable of causing shock, burns, or death.
RefertoGroup5ControllerUser’sGuide381333–126
forATSstatusdisplaymessages,timedelays,pickup
&dropoutsettings,an

Summary of the content on the page No. 2

Catalog NumberIdentification Typical4000Seriescatalogno. forJ–design, 2pole, 260amp, 240V, ADTSinType1enclosure: J 4ADTS A 2 260 F 5 C design prefix letter Neutral Phase Poles Amperes Voltage Controller Enclosure A –solid 2–singleØ A 115 5–standard C –type1 150 1200 J 400 B –switched 3–threeØ B 120 K 415 5X–if F –type3R 260 1600 accessories G –type4 C – overlapping 400 2000 C 208 L 440 ordered H –type4X 600 2600 blank– none D 220 M 460 800 3000 E 230 N 480 L –type12 blank– open type F 240 P 550

Summary of the content on the page No. 3

SECTION1 INSTALLATION ASCO4000SeriesAutomaticDelayed–TransitionTrans- should be tested to verify that they are not defective or ferSwitchesarefactorywiredandtested.Fieldinstalla- havebeendamagedduringinstallation. tionsimplyrequiresmountingandconnectionofservice Connecting PowerConductors cables, andauxiliarycontrolcircuits(ifrequired). AWiringDiagramisfurnishedwiththeASCO4000Series Remove the Shipping Skid 4ADTS (separate from this manual). Refer to this For large switches, open the front door

Summary of the content on the page No. 4

INSTALLATION (continued) ControllerGround A groundingwire must be connected to the controller’s lower left mounting stud. Because the controller is mountedontheenclosuredoor,aconductivestrapmust be used between the enclosure and the door. This connection provides proper grounding which does not EngineStarting TS Auxiliary Contacts relyuponthedoorhinges. Signals Feature 14A& 14B 5amps,32VDC 10 amps, 32 VDC Harnesses 5ampsresistive28VDC 10 amps250 VAC or120 VAC max. general purpose TB TerminalBloc

Summary of the content on the page No. 5

INSTALLATION (continued) FunctionalTest TheFunctionalTestconsistsofthreechecks: ❐ 1 — ManualOperationTest,pages1–3through1–6 Emergency contacts (upper shaft) ❐ 2—VoltageChecks,page1–7 contact window indicators position ❐ 3 — ElectricalOperation, page1–8 O is open indicators C is closed (right side) Do these checks in the order presented Normal contacts to avoid damaging the ATS. (lower shaft) Read all instructions on the Wiring Diagram and labels affixed to the ATS. Note the control features tha

Summary of the content on the page No. 6

INSTALLATION (continued) J–design 150–600amp H–design 800–1200amp left side of transfer switch left side of transfer switch lobes on weights prevent both N&Econtacts maintenance from being handle closed at the same time Emergency source contact shaft hub Emergency source contact shaft hub clip maintenance handle Normal source contact shaft hub clips Normal source contact shaft hub Figure 1-6. Maintenance handle on 150–600 amp. Figure 1-9. Maintenance handle on 800–1200 amp. J–design transfer swi

Summary of the content on the page No. 7

INSTALLATION (continued) Do notmanually operate the transfer switch until bothpower sources are disconnected: open bothcircuitbreakers. Table C. Maintenance handle positions on 150–1200 amp. transfer switches. . J–design 150---600 A H–design 800---1200 A 1 2 Transfer Switch Maintenance Interlocked Shafts Interlocked Weights ShaftIndicators Position Handle Link between contact Lobes prevent shafts prevents closing closing both N & E both N & E contacts contacts up weight hub hub E=O E uppercontac

Summary of the content on the page No. 8

INSTALLATION (continued) Insert handle Turn counterclockwise into hole Emergency to OPEN contacts. Grasp handle (spring fully contacts firmly with Turn clockwise to compressed) both hands CLOSE contacts. Slide the hub onto the window shaft and insert the pin. indicators OPEN or CLOSED Normal counterclockwise DOWN clockwise DOWN contacts OPENS the contacts OPENS the contacts Pull out shaft to open Emergency Pull out shaft to close Emergency source contacts (upper) source contacts (upper) contact

Summary of the content on the page No. 9

INSTALLATION (continued) Pressfor15 Sec. observe these lights Figure 1-14. Standard controls and indicators. Close the normalsource (utility) circuit breaker. Two two left 2 --- Voltage Checks lights should come on. The 1 normalsource Accepted (upper First check the nameplate on the transfer switch; the left) and the Transfer Switch rated voltage must be the same as the normal and Position connected to normal emergencylinevoltages. (lower left) lights should be on. Carefully use an accurate volt

Summary of the content on the page No. 10

INSTALLATION (continued) step 2 step 4 press these buttons If this light is on, the buttons willnot Pressfor15 Sec. work untilthe controls are unlocked. observe If this light is blinking, the user these lights controls are unlocked for 5 minutes. Figure 1-15. User controls and indicators. The twoleftlights should be on; 3 --- ElectricalOperation the normal source Accepted (upperleft)and the Transfer 1 Thisprocedurewillchecktheelectricaloperationofthe Switch Position connected to automatictransfe

Summary of the content on the page No. 11

SECTION2 TESTING&SERVICE TRANSFER TEST DISCONNECTING THE CONTROLLER Operatethe4000SeriesADTSatleastonceamonthby The harness disconnect plugs are furnished for repair following the five–step Electrical Operation Transfer purposes only and should not have to be unplugged. If Testprocedureonpage1–7. thecontrollermust beisolated, followthesesteps: Disconnecting the Plugs PREVENTIVE MAINTENANCE Reasonable care in preventive maintenance will insure Do notunplug the controller high reliability and long

Summary of the content on the page No. 12

TESTING&SERVICE (continued) 2. Use the maintenance handle to manually operate the MANUAL LOADTRANSFER transferswitch to the opposite source. First open the This procedure will manually transfer the load if the closed contacts, then close the other contacts. Do not controllerisdisconnected. try toclose bothNormal andEmergency contact.See Manual Operation onpage 1–3 through1–6. 3. Thenremovethemaintenancehandle.. Do notmanually operate the transfer switch until bothpower sources are disconnected (

Summary of the content on the page No. 13

INDEX A I R auxiliarycircuits,1–2 indicators,contactposition,1–3 ratinglabel, cover inspection, 2–1 replacementparts,2–1 C installation, 1–1 S cable interlockedweights,1–6 lugs, 1–2 service preparation,1–2 L intheU.Scall1–800–800–2726 catalognumber, insidecover inCanadacall1–888–234–2726 labels, enginestartcontacts, 1–2 cleaning, 2–1 settings rating, cover see ControllerUser’s Guide connections lights, 1–7, 1–8 line, 1–1 shaftindicators,1–3 LoadDisconnectedlight, 1–8 contactpositionindicators,1–


Alternative user manuals
# User manual Category Download
1 Emerson 5081-T User manual Switch 38
2 Emerson ASCO 300 Series User manual Switch 747
3 Emerson ASCO 7000 User manual Switch 91
4 Emerson 7000 User manual Switch 58
5 Emerson ASCO 185 User manual Switch 45
6 Emerson 7ADTB User manual Switch 3
7 Emerson 185 User manual Switch 7
8 Emerson B-294 HD User manual Switch 0
9 Emerson Autochangeover Controllers AC8 User manual Switch 7
10 Emerson 214A401 User manual Switch 0
11 Emerson 214A400 User manual Switch 3
12 Emerson 214A404 User manual Switch 0
13 Emerson 260 User manual Switch 0
14 Emerson 300 User manual Switch 1
15 Emerson 386 User manual Switch 0
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4