Emerson 5150 user manual

User manual for the device Emerson 5150

Device: Emerson 5150
Category: Switch
Manufacturer: Emerson
Size: 3.33 MB
Added : 1/15/2014
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson 5150. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson 5150.

For your convenience

If looking through the Emerson 5150 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson 5150 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson 5150 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson 5150 User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson 5150 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson 5150. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation Manual

5100 Series, Catalog 5150
Connectivity Module
For use with Automatic Transfer Switches,
Power Manager, & Digital Power Meter

Section Page
Welcome............................................................................................................. ii
Overview, Specifications, Installation Overview, DIP Switch (RS485)..........

Summary of the content on the page No. 2

ii Welcome Connectivity Module Who Should Use this Installation Manual This manual for the Connectivity Module should be used to assist individuals who will: • install the Connectivity Module (mount and wire) • configure the Connectivity Module • enter in information about your Automatic Transfer Switches (7000 & 4000 Series, Series 300, ASCO 940,962,436,434,447,448) • use Ethernet access to monitor Connectivity Module (connected devices) ® Prerequisites A working k

Summary of the content on the page No. 3

Connectivity Module Overview, Specifications, Installation Overview, DIP Switch iii Overview Installation Overview The Connectivity Module brings together several different serial devices that communicate at different 1. Determine the kind of network to use to connect the baud rates and with different protocols to a common various devices to the Connectivity Module. Ethernet media. It can communicate with up to eight 2. If a RS485 network will be used, do not install the cli

Summary of the content on the page No. 4

iv Outline and Mounting Drawing Connectivity Module

Summary of the content on the page No. 5

v Wiring Diagrams Connectivity Module

Summary of the content on the page No. 6

Connectivity Module Wiring Diagrams vi

Summary of the content on the page No. 7

vii Wiring Diagrams Connectivity Module

Summary of the content on the page No. 8

Connectivity Module Wiring Diagrams viii

Summary of the content on the page No. 9

Connectivity Module Status LEDs ix Status LEDs LED LED Description LED Function / Mode of Operation Solid GREEN – functioning as a Connectivity Module (Acc. 72E). Power indication status. POWER GREEN/AMBER Solid AMBER – functioning as a Serial Module (Acc. 72A). Data receiving status. RX Blinking GREEN – indicates receiving data from a client. GREEN Data transmit status. Blinking GREEN – indicates transmitting data to a client. TX GREEN

Summary of the content on the page No. 10

1-1 Installation Connectivity Module How to Install the Connectivity Module How to Install the Connectivity Module on 7000 & 4000 Series and Series 300 ATSs on ASCO 940/962 ATSs The Connectivity Module (CM) mounts on a DIN rail The Connectivity Module (CM) mounts on a DIN rail under the ATS Controller (Group 5 & 1). A short serial near the ATS Control Panel. A separate power supply is cable connects the CM to the Controller. If a Power needed unless it is connected to a Power Ma

Summary of the content on the page No. 11

Connectivity Module Installation 1-2 How to Install the Connectivity Module for How to Test Communication to the a stand-alone Power Manager or Digital Connectivity Module Power Meter You need the following settings from your network administrator for each Connectivity Module (CM) The Connectivity Module (CM) mounts on a DIN rail connected to an Automatic Transfer Switch (ATS), Power near the Power Manager (PM) or Digital Power Meter Manager (PM), or Digital Power Meter (DP

Summary of the content on the page No. 12

1-3 Installation Connectivity Module How to View & Change Configuration Pages How to View Pages from a Connectivity from a Connectivity Module Module after it is installed To view and change configuration pages on a client After installation, testing, and configuration is completed, computer, follow these steps: to view pages on a client computer, follow these steps: 1. Be sure that your computer is connected to the Internet. 1. Be sure that your computer is connected t

Summary of the content on the page No. 13

Connectivity Module 7000 & 4000 Series ATSs 2-1 Device Configurator Screen for 7000 & 4000 Series ATSs The Device Configurator Screen for 7000 & 4000 Series ATSs shows the Group 5 controller configuration settings (right side) and Connectivity Module (server) configuration settings (left side) for the selected ATS. Group 5 Controller Configuration (right side) Enter or change the ATS Name (8 char. max.)and the ATS Location (20 char. max.). Press the Update button when finished t

Summary of the content on the page No. 14

2-2 7000 & 4000 Series ATSs Connectivity Module Device Configurator Screen for 7000 & 4000 Series ATSs with a PM or DPM If a Power Manager (PM) or Digital Power Meter (DPM) is used with a 7000 & 4000 Series ATS, a button appears on the lower left corner of the Connectivity Module Device Configurator screen. Press the Config PM button to display the Power Manager or Power Meter Configuration screen (right side). Power Manager or Power Meter Configuration Enter or change the PM

Summary of the content on the page No. 15

Connectivity Module 7000 & 4000 Series ATSs 2-3 Detail Screen for 7000 & 4000 Series ATSs The Detail Screen for 7000 & 4000 Series ATSs shows the switch location, ratings, timer settings, actual timer values, pickup and dropout settings, event logging, and other status indications. ATS one-line icon shows position & source status (green or red circle means source is acceptable, grey circle means source is not acceptable) ATS location Active time delays ATS name Status of Nor

Summary of the content on the page No. 16

3-1 Series 300 ATSs Connectivity Module Device Configurator Screen for Series 300 ATSs The Device Configurator Screen for Series 300 ATSs shows the Group 1 controller configuration settings (right side) and the Connectivity Module (server) configuration settings (left side) for the selected ATS. Group 1 Controller Configuration (right side) Enter or change the ATS Name (8 char. max.) and the ATS Location (20 char. max.). Press the Update button when finished to save the Group

Summary of the content on the page No. 17

Connectity Module Series 300 ATSs 3-2 Device Configurator Screen for Series 300 ATSs with a PM or DPM If a Power Manager (PM) or a Digital Power Meter (DPM) is used with a Series 300 ATS, a button appears on the lower left corner of the Connectivity Module Device Configurator screen. Press the Config PM button to display the Power Manager or Power Meter Configuration screen (right side). Power Manager or Power Meter Configuration Enter or change the PM or DPM Name (8 char. max.

Summary of the content on the page No. 18

3-3 Series 300 ATSs Connectivity Module Detail Screen for Series 300 ATSs The Detail Screen for Series 300 ATSs shows the switch location, ratings, timer settings, actual timer values, pickup and dropout settings, and other status indications. ATS one-line icon shows position & source status (green or red circle means source is acceptable, grey circle means source is not acceptable) Status of ATS location Emergency Source ATS type ATS name Status of Normal Source Actua

Summary of the content on the page No. 19

Connectivity Module ASCO 940/962 ATSs 4-1 Device Configurator Screen for ASCO 940/962 ATSs The Device Configurator Screen for ASCO 940/962 ATSs shows the Group 7A controller configuration settings (right side) and the Connectivity Module (server) configuration settings (left) for the selected ATS. Group 7A Controller Configuration (right side) Enter or change the ATS Name (18 char. max.) and ATS Nominal Voltage (must be entered to get correct reading). Press the Update button

Summary of the content on the page No. 20

4-2 ASCO 940/962 ATSs Connectivity Module Detail Screen for ASCO 940/962 ATSs The Detail Screen for ASCO 940/962 ATSs shows the switch location, ratings, timer settings, actual timer values, pickup and dropout settings, and other status indications. ATS one-line icon shows position & source status (green or red circle means source is acceptable, grey circle means source is not acceptable) Status of ATS name Status of Normal Source Emergency Source Actual voltage Actua


Alternative user manuals
# User manual Category Download
1 Emerson 5081-T User manual Switch 38
2 Emerson ASCO 300 Series User manual Switch 747
3 Emerson ASCO 7000 User manual Switch 91
4 Emerson 7000 User manual Switch 58
5 Emerson ASCO 185 User manual Switch 45
6 Emerson 7ADTB User manual Switch 3
7 Emerson 185 User manual Switch 7
8 Emerson B-294 HD User manual Switch 0
9 Emerson Autochangeover Controllers AC8 User manual Switch 7
10 Emerson 214A401 User manual Switch 0
11 Emerson 214A400 User manual Switch 3
12 Emerson 214A404 User manual Switch 0
13 Emerson 260 User manual Switch 0
14 Emerson 300 User manual Switch 1
15 Emerson 386 User manual Switch 0
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4