Summary of the content on the page No. 1
TruCluster Software Products
Hardware Configuration Technical Update for
DS-DWZZH-05 UltraSCSI Hub
December 1998
Product Version: TruCluster Production Server
Software Software Version 1.4A and
TruCluster Production Server
Software Version 1.5 and TruCluster
Available Server Software 1.4A and
TruCluster Available Server Software
Version 1.5
Operating System and Version: Compaq’s DIGITAL UNIX Version
4.0B and Compaq’s DIGITAL UNIX
Version 4.0D
This technical update describes how to configure the DS
Summary of the content on the page No. 2
© Compaq Computer Corporation 1998 All rights reserved. The following are trademarks of Compaq Computer Corporation: ALL–IN–1, Alpha AXP, AlphaGeneration, AlphaServer, AltaVista, ATMworks, AXP, Bookreader, CDA, DDIS, DEC, DEC Ada, DEC Fortran, DEC FUSE, DECnet, DECstation, DECsystem, DECterm, DECUS, DECwindows, DTIF, Massbus, MicroVAX, OpenVMS, POLYCENTER, PrintServer, Q–bus, StorageWorks, TruCluster, ULTRIX, ULTRIX Mail Connection, ULTRIX Worksystem Software, UNIBUS, VAX, VAXstation, VMS, XUI,
Summary of the content on the page No. 3
Contents About This Technical Update 1 DS-DWZZH-05 UltraSCSI Hub 1.1 General Overview ..................................................... 1–1 1.2 DS-DWZZH Overview ................................................ 1–2 2 Using the DS-DWZZH-05 UltraSCSI Hub in a Cluster Configuration 2.1 DS-DWZZH-05 UltraSCSI Hub Description ..................... 2–1 2.2 DS-DWZZH-05 Configuration Guidelines ........................ 2–1 2.3 DS-DWZZH-05 Fair Arbitration ................................... 2–3 2.4 DS-
Summary of the content on the page No. 4
2–4 TruCluster Configuration Using a KZPBA-CB UltraSCSI Adapter, a DS-DWZZH-05 UltraSCSI Hub, and an HSZ70 RAID Array Controller .............................................. 2–11 Tables 2–1 DS-DWZZH UltraSCSI Hub Maximum Configurations ........ 2–2 2–2 Hardware Components Used in the Configuration Shown in Figure 2–3 ............................................................. 2–10 2–3 Hardware Components Used in the Configuration Shown in Figure 2–4 ..............................................
Summary of the content on the page No. 5
About This Technical Update This technical update provides important information about using the TM DS-DWZZH-05 UltraSCSI hub with the TruCluster software products. Audience If you plan to use a DS-DWZZH-05 UltraSCSI hub in a TruCluster hardware configuration, read this addendum to the TruCluster Software Products Hardware Configuration manual. Organization This technical update contains an introductory chapter and a chapter covering the use and configuration of the DS-DWZZH-05 UltraSCSI hub in a T
Summary of the content on the page No. 6
Summary of the content on the page No. 7
1 DS-DWZZH-05 UltraSCSI Hub This technical update to the TruCluster Software Products Hardware Configuration manual provides important information about support for the DS-DWZZH-05 UltraSCSI hub with the TruCluster Production Server Software Version 1.4A and TruCluster Production Server Software Version 1.5 and TruCluster Available Server Software Version 1.4A and TruCluster Available Server Software Version 1.5 products. 1.1 General Overview The DS-DWZZH-05 UltraSCSI hub was recently qualified fo
Summary of the content on the page No. 8
this technical update provides the DS-DWZZH-05 configuration information that would appear in Chapter 4 of the TruCluster Software Products Hardware Configuration manual. 1.2 DS-DWZZH Overview The DS-DWZZH series UltraSCSI hubs are SCSI-2 and draft SCSI-3 compliant SCSI 16-bit signal converters capable of data transfer rates of up to 40 MB per second. Cluster member systems and HSZ50 or HSZ70 RAID array controllers are radially connected to the hub ports. A DS-DWZZH UltraSCSI hub: • Improves the r
Summary of the content on the page No. 9
2 Using the DS-DWZZH-05 UltraSCSI Hub in a Cluster Configuration 2.1 DS-DWZZH-05 UltraSCSI Hub Description The DS-DWZZH-05 UltraSCSI hub is supported on TruCluster Available Server Software Version 1.4A and TruCluster Available Server Software Version 1.5 and TruCluster Production Server Software Version 1.4A and TruCluster Production Server Software Version 1.5. The DS-DWZZH-05: • Is a 5.25-inch StorageWorks Building Block (SBB) • Has five VHDCI differential SCSI bus connectors • Uses SCSI ID 7 w
Summary of the content on the page No. 10
• A StorageWorks DS-BA356 shelf (which has the required 180-watt power supply). • A wide BA356 which has been upgraded to the 180-watt power supply with the DS-BA35X-HH option. _____________________ Note _____________________ Dual power supplies are recommended for any BA356 shelf containing a DS-DWZZH-05 UltraSCSI hub in order to provide a higher level of availability between cluster member systems and storage. • The lower righthand device slot of the BA370 shelf within the RA7000 or ESA 10000
Summary of the content on the page No. 11
Table 2–1: DS-DWZZH UltraSCSI Hub Maximum Configurations (cont.) a DS-DWZZH-03 DW-DWZZH-05 Disk Drives Personality bc Module 1 1 2 Installed 0 1 3 Installed a DS-DWZZH UltraSCSI hubs and disk drives may coexist in a storage shelf. Installed disk drives are not associated with the DS-DWZZH UltraSCSI hub SCSI bus segments; they are on the SCSI bus connected to the personality module. b If the personality module is installed, you can install a maximum of four DS-DWZZH-03 UltraSCSI hubs. c The person
Summary of the content on the page No. 12
conventional manner; the highest SCSI ID asserted during the arbitration cycle obtains use of the SCSI bus. _______________________ Note _______________________ Host port SCSI ID assignments are not linked to the physical port when fair arbitration is disabled. The DS-DWZZH-05 retains SCSI ID 7 regardless of whether fair aarbitrarion is enabled or not. 2.4 DS-DWZZH-05 Address Configurations The DS-DWZZH-05 has two addressing modes; wide addressing mode and narrow addressing mode. With either addr
Summary of the content on the page No. 13
Figure 2–1: DS-DWZZH-05 Front View Fair Disable Controller Host Port Port SCSI ID SCSI ID 6 - 4 2 (14) (6 - 0) Power Host Port SCSI ID 3 Busy (15) Host Port Host Port SCSI ID SCSI ID 0 1 (12) (13) ZK-1447U-AI Using the DS-DWZZH-05 UltraSCSI Hub in a Cluster Configuration 2–5
Summary of the content on the page No. 14
Figure 2–2: DS-DWZZH-05 Rear View W1 ZK-1448U-AI 2.5 SCSI Bus Termination Power Each host adapter connected to a DS-DWZZH-05 UltraSCSI hub port must supply termination power (termpwr) to enable the termination resistors on each end of the SCSI bus segment. If the host adapter is disconnected from the hub, the port is disabled. Only the UltraSCSI bus segment losing termination power is affected. The remainder of the SCSI bus operates normally. 2.6 DS-DWZZH-05 Indicators The DS-DWZZH-05 has two in
Summary of the content on the page No. 15
To configure a TruCluster configuration using a DS-DWZZH-05 UltraSCSI hub, follow these steps: 1. Configure and install the DS-DWZZH-05 UltraSCSI hub (Section 2.7.1) 2. Verify that the host adapter termination is installed and cable the host adapter to the DS-DWZZH-05 UltraSCSI hub (Section 2.7.2) 3. Cable the RAID array controller to the hub: • HSZ50 (Section 2.7.3.1) • HSZ70 (Section 2.7.3.2) 2.7.1 Installing the DS-DWZZH-05 UltraSCSI Hub All existing versions of Compaq’s DIGITAL UNIX operating s
Summary of the content on the page No. 16
• Ensure that no member systems’ host adapter SCSI ID is set at 7 (because the DS-DWZZH-05 uses SCSI ID 7). • Connect a BN38C cable between the host adapter and the appropriate DS-DWZZH-05 UltraSCSI hub port. Each connection forms a SCSI bus segment with the host adapter and the hub. The maximum length of a SCSI bus segment, including cable and internal device bus length, is 25 meters. 2.7.3 Cabling the RAID array Storage Subsystem to the DS-DWZZH-05 UltraSCSI Hub To prepare the storage portion
Summary of the content on the page No. 17
Figure 2–3 shows a sample configuration that uses KZPSA-BB SCSI adapters, a DS-DWZZH-05 UltraSCSI hub, and an HSZ50 RAID array controller. Figure 2–3: TruCluster Configuration Using KZPSA SCSI Adapters, a DS-DWZZH-05 UltraSCSI Hub, and an HSZ50 RAID Array Controller AlphaServer Member System 1 T KZPSA-BB 1 1 KZPSA-BB DS-DWZZH-05 T T 1 T AlphaServer T Member T T System 2 2 HSZ50 1 1 4 KZPSA-BB KZPSA-BB T T 2 HSZ50 T AlphaServer AlphaServer Member Member 3 System 3 System 4 ZK-1449U-AI _____________
Summary of the content on the page No. 18
Table 2–2: Hardware Components Used in the Configuration Shown in Figure 2–3 Callout Number Description ab 1 BN38C HD68 to VHDCI cable 2 H885-AA HD68 trilink connector 3 H879-AA HD68 terminator b 4 BN21K or BN21L HD68 cable a The maximum length of the SCSI bus segment, including BN38C cable and internal device length, must not exceed 25 meters. b The maximum length of the SCSI bus segment, including the combined length of the BN38C and BN21K (or BN21L) cables, must not exceed 25 meters. 2.7.3.2 C
Summary of the content on the page No. 19
Figure 2–4: TruCluster Configuration Using a KZPBA-CB UltraSCSI Adapter, a DS-DWZZH-05 UltraSCSI Hub, and an HSZ70 RAID Array Controller AlphaServer Member System 1 T KZPBA-CB 1 1 KZPBA-CB DS-DWZZH-05 T T 4 T AlphaServer T Member T T System 2 2 HSZ70 1 1 4 KZPBA-CB KZPBA-CB T T 2 HSZ70 T AlphaServer AlphaServer Member Member 3 System 3 System 4 ZK-1460U-AI _______________________ Note _______________________ The systems shown in Figure 2–4 use KZPBA-CB UltraSCSI adapters. They could be KZPSA-BB S
Summary of the content on the page No. 20
Table 2–3: Hardware Components Used in the Configuration Shown in Figure 2–4 Callout Number Description a 1 BN38C HD68 to VHDCI cable 2 H8861-AA VHDCI trilink connector 3 H8863-AA VHDCI terminator b 4 BN37A VHDCI cable a The maximum length of the SCSI bus segment, including BN38C cable and internal device length, must not exceed 25 meters. b The maximum length of the SCSI bus segment, including the combined length, of BN37A cables and internal device length, must not exceed 25 meters. 2–12 Using