Summary of the content on the page No. 1
CHAPTER2
Switch Installation
This chapter describes how to start your switch and how to interpret the power-on self-test (POST) that
ensures proper operation. It also describes how to install the switch.
Read the topics and perform the procedures in this order:
• Preparing for Installation, page 2-1
� Verifying Switch Operation, page 2-5
� Mounting the Switch, page 2-5
� Installing a Cover for the Reset Button (Optional), page 2-24
� Installing the Power Cord Retainer (Optional), page 2-25
�
Summary of the content on the page No. 2
Chapter 2 Switch Installation Preparing for Installation Warning Read the wall-mounting instructions carefully before beginning installation. Failure to use the correct hardware or to follow the correct procedures could result in a hazardous situation to people and damage to the system. Statement 378 Warning Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001 Warning Read the installation instructions before connecting the syst
Summary of the content on the page No. 3
Chapter 2 Switch Installation Preparing for Installation Warning For connections outside the building where the equipment is installed, the following ports must be connected through an approved network termination unit with integral circuit protection: 10/100/1000 Ethernet. Statement 1044 Warning To prevent the system from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of: 113°F (45°C) Statement 1047 Note For Catalyst 3560CG-8PC-S,
Summary of the content on the page No. 4
Chapter 2 Switch Installation Powering the Switch � Temperature around the unit does not exceed 113°F (45°C). If the switch is installed in a closed environment or in a multirack assembly, the temperature around it might be greater than normal room temperature. � Humidity around the switch must not exceed 95 percent. � Altitude at the installation site must not be greater than 10,000 feet (3,049 meters). � Do not place any items on the top of the switch. � Do not wall-mount the switch w
Summary of the content on the page No. 5
Chapter 2 Switch Installation Verifying Switch Operation Note You can use both the uplink port and the auxiliary power adapter. However, the auxiliary power input takes precedence. Catalyst 3560CPD-8PT-S � Connect a 10/100/1000 uplink port to a PoE+ switch, such as a Catalyst 3750-X. Or � Plug the auxiliary power adapter cord into the switch AUX power connector and into an AC power outlet. Note You can use both the uplink port and the auxiliary power adapter. However, the auxiliary pow
Summary of the content on the page No. 6
Chapter 2 Switch Installation Mounting the Switch On a Desk or Shelf (without Mounting Screws) Step 1 Locate the adhesive strip with the rubber feet in the accessory kit. Step 2 Remove the four rubber feet from the adhesive strip, and attach them to the recessed areas on the bottom of the unit. This prevents the switch from sliding on the desk or shelf. Note We strongly recommend that you attach the rubber feet. Doing so helps prevent airflow restriction and overheating. Step 3 Place t
Summary of the content on the page No. 7
Chapter 2 Switch Installation Mounting the Switch Figure 2-1 Installing the Mounting Screws on Top of a Desk or a Shelf 2 3 1 1 Screw template 3 Desk or shelf 2 Screws Step 3 Peel the adhesive strip off the bottom of the screw template, and attach it to the top of the desk or shelf. Step 4 Use a 0.144-inch (3.7 mm) or a #27 drill bit to drill a 1/2-inch (12.7 mm) hole in the three screw template slots. Step 5 Insert three screws in the slots on the screw template, and tighten them until
Summary of the content on the page No. 8
Series PD SYST STAT DPLX 1234 5678 SPD 1 2 PoE PD MODE CONSOLE POWER OVER ETHERNET Chapter 2 Switch Installation Mounting the Switch Figure 2-2 Mounting the Switch on Top of a Desk or Shelf 3 1 2 1 Slides on this way 3 Desk or shelf 2 Screws After you mount the switch, see the “After Installing the Switch” section on page 2-31 for information about configuring the switch. Under the Desk- or Shelf-Mounting Step 1 Use the screw template to align the mounting screw holes and also as a gu
Summary of the content on the page No. 9
Chapter 2 Switch Installation Mounting the Switch Figure 2-3 Installing the Mounting Screws Under a Desk or Shelf 1 2 3 4 3 1 Desk or shelf 3 Screws 2 Screw template 4 Adhesive Step 4 Use a 0.144-inch (3.7 mm) or a #27 drill bit to drill a 1/2-inch (12.7 mm) hole in the three screw template slots. Step 5 Insert three screws in the slots on the screw template, and tighten until they touch the top of the screw template. Step 6 Remove the screw template from underneath the desk or shelf. S
Summary of the content on the page No. 10
Chapter 2 Switch Installation Mounting the Switch Figure 2-4 Mounting the Switch Under a Desk or Shelf 1 2 3 1 Desk or shelf 3 Slides on this way 2 Screws After you mount the switch, see the “After Installing the Switch” section on page 2-31 for information about configuring the switch. Wall-Mounting Warning Read the wall-mounting instructions carefully before beginning installation. Failure to use the correct hardware or to follow the correct procedures could result in a hazardous si
Summary of the content on the page No. 11
Chapter 2 Switch Installation Mounting the Switch Step 1 Locate the screw template. The template is used to align the mounting screw holes. Note Figure 2-5 shows the measurements for the location of the screws on the switch. Step 2 Position the screw template so that the two side-by-side slots face toward the floor, as shown in Figure 2-6. For the best support of the switch and cables, make sure that you attach the switch securely to a wall stud or to a firmly attached plywood mounting
Summary of the content on the page No. 12
THIS SIDE AWAY FROM MOUNTING SURFACE CABLE SIDE ENTRY Chapter 2 Switch Installation Mounting the Switch Figure 2-6 Installing the Mounting Screws on the Wall 1 2 2 3 2 Figure 2-7 Installing the Switch on a Wall 1 3 2 2 2 Step 8 Place the switch onto the mounting screws, and slide it down until it locks in place. See Figure 2-7. Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2-12 OL-23803-02 157828 208926 RESET AUX 53V , 1.5A
Summary of the content on the page No. 13
Chapter 2 Switch Installation Mounting the Switch With a Mounting Tray The mounting kit (part number CMP-MGNT-TRAY=) is optional. You can order it when you order your switch, or you can order it later from your Cisco representative. The mounting kit ships contents: � Two number-10 Phillips pan-head screws � Three number-8 Phillips pan-head screws � Mounting tray � Magnet You can use the mounting tray by itself with mounting screws, or with a magnet. Mounting Tray with Screws You can use
Summary of the content on the page No. 14
Series PD SYST STAT DPLX 1234 5678 SPD 1 2 PoE PD MODE CONSOLE POWER OVER ETHERNET Chapter 2 Switch Installation Mounting the Switch 1 Number-8 Phillips pan-head screws 3 Desk or shelf 2 Mounting tray Step 4 Place the switch onto the mounting screws, and slide the switch until it locks into place. See Figure 2-9. Figure 2-9 Installing the Switch on the Mounting Tray 1 2 3 4 1 Switch 3 Mounting tray 2 Sliding direction 4 Desk Catalyst 3560-C and 2960-C Switch Hardware Installation Guide 2
Summary of the content on the page No. 15
Series PD SYST STAT DPLX 12 3 45 6 7 8 SPD 1 2 PoE PD MODE CONSOLE POWER OVER ETHERNET Chapter 2 Switch Installation Mounting the Switch Step 5 Use the two number-10 Phillips pan-head screws to secure the mounting tray to the switch. See Figure 2-10. Figure 2-10 Securing the Mounting Tray to the Switch 1 2 1 Switch 2 Number-10 Phillips pan-head screws Warning To prevent airflow restriction, allow clearance around the ventilation openings to be at least: 3 in. (7.6 cm) Statement 1076 Mou
Summary of the content on the page No. 16
Series PD SYST STAT DPLX 1234 5678 SPD 1 2 PoE PD MODE CONSOLE POWER OVER ETHERNET Series PD SYST STAT 12 3 45 6 7 8 DPLX SPD 1 2 PoE PD MODE CONSOLE POWER OVER ETHERNET Chapter 2 Switch Installation Mounting the Switch Step 1 Place the switch on the mounting tray. See Figure 2-11. Figure 2-11 Placing the Switch on the Mounting Tray 1 2 1 Switch 2 Mounting tray Step 2 Use the two number-10 Phillips pan-head screws to secure the mounting tray to the switch. See Figure 2-12. Figure 2-12
Summary of the content on the page No. 17
Chapter 2 Switch Installation Mounting the Switch Warning Read the wall-mounting instructions carefully before beginning installation. Failure to use the correct hardware or to follow the correct procedures could result in a hazardous situation to people and damage to the system. Statement 378 Caution Do not wall-mount the switch with its front panel facing up. Following safety regulations, wall-mount the switch with its front panel facing down or to the side, to allow sufficient airfl
Summary of the content on the page No. 18
Series PD SYST STAT DPLX 1 2 34 5 678 SPD 1 2 PoE PD MODE CONSOLE POWER OVER ETHERNET Chapter 2 Switch Installation Mounting the Switch In a Rack Installing the switch in a rack requires an optional bracket kit that is not included with the switch. You can order these kits from your Cisco representative: � 19-inch rack-mounting brackets (RCKMNT-19-CMPCT=) � 23- and 24-inch rack-mounting brackets (RCKMNT-23-CMPCT=) Warning To prevent bodily injury when mounting or servicing this unit in
Summary of the content on the page No. 19
r 1 2 5 1 2 P V Se ies PD SYST STAT DPLX 34 678 SPD oE PD MODE CONSOLE POWER O ER ETHERNET Series PD SYST STAT DPLX 12 34 5678 SPD 1 2 PoE PD MODE CONSOLE POWER OVER ETHERNET Chapter 2 Switch Installation Mounting the Switch Figure 2-15 shows how to attach a 23-inch bracket to one side of the switch. Follow the same steps to attach the second bracket to the opposite side. Figure 2-15 Attaching the 23-inch Brackets for Rack-Mounting 1 1 Phillips flat-head screw Mounting the Switch in a
Summary of the content on the page No. 20
Series PD SYST STAT 1234 5 678 DPLX SPD 1 2 PoE PD MODE CONSOLE POWER OVER ETHERNET Chapter 2 Switch Installation Mounting the Switch On a DIN Rail The DIN-mount kit (part number CMP-DIN-MNT=) is optional. You can order it when you order your switch, or you can order it later from your Cisco representative. The DIN-mount kit contains: � Two number-10 Phillips pan-head screws � DIN rail mount To install the switch on a DIN rail, follow the instructions described in these sections: � Att