Cisco Systems CATALYST 6500 WS-X6066-SLB-S-K9 user manual

User manual for the device Cisco Systems CATALYST 6500 WS-X6066-SLB-S-K9

Device: Cisco Systems CATALYST 6500 WS-X6066-SLB-S-K9
Category: Switch
Manufacturer: Cisco Systems
Size: 1.97 MB
Added : 6/22/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Cisco Systems CATALYST 6500 WS-X6066-SLB-S-K9. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Cisco Systems CATALYST 6500 WS-X6066-SLB-S-K9.

For your convenience

If looking through the Cisco Systems CATALYST 6500 WS-X6066-SLB-S-K9 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Cisco Systems CATALYST 6500 WS-X6066-SLB-S-K9 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Cisco Systems CATALYST 6500 WS-X6066-SLB-S-K9 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Cisco Systems CATALYST 6500 WS-X6066-SLB-S-K9 User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Cisco Systems CATALYST 6500 WS-X6066-SLB-S-K9 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Cisco Systems CATALYST 6500 WS-X6066-SLB-S-K9. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


Catalyst 6500 Series Switch Content Switching
Module with SSL Installation Note
Product Number: WS-X6066-SLB-S-K9
This publication describes how to install the Content Switching Module with SSL (CSM-S) in the
Catalyst 6500 series switches and includes the software and hardware requirements.
Note The term SSL daughter card refers to a Secure Socket Layer (SSL) termination daughter card that
accelerates SSL transactions. Except where specifically differentiated, the term Content Switching
Mo

Summary of the content on the page No. 2

Safety Overview � Obtaining Technical Assistance, page 26 � Obtaining Additional Publications and Information, page 27 Safety Overview Warning IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its

Summary of the content on the page No. 3

Safety Overview Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert

Summary of the content on the page No. 4

Safety Overview Varning! VIKTIGA SÄKERHETSANVISNINGAR Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanliga förfaranden för att förebygga olyckor. Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning. SPARA DESSA ANVISNINGAR Catalyst 6500

Summary of the content on the page No. 5

Safety Overview Aviso INSTRUÇÕES IMPORTANTES DE SEGURANÇA Este símbolo de aviso significa perigo. Você se encontra em uma situação em que há risco de lesões corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os circuitos elétricos e familiarize-se com as práticas padrão de prevenção de acidentes. Use o número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham o dispositivo.

Summary of the content on the page No. 6

Safety Overview Catalyst 6500 Series Switch Content Switching Module with SSL Installation Note 6 78-16856-01

Summary of the content on the page No. 7

Front Panel Description Front Panel Description These sections describe the physical attributes of the CSM-S: � LEDs, page 8 � RJ-45 Connector, page 9 � SSL Connector, page 9 Figure 1 shows the CSM-S front panel. Figure 1 Content Switching Module with SSL Front Panel SSL Certificate Management Status Connector LED RJ-45 Crypto Note The RJ-45 connector is covered by a removable plate. Catalyst 6500 Series Switch Content Switching Module with SSL Installation Note 78-16856-01 7 113438

Summary of the content on the page No. 8

Front Panel Description Note You are required to make initial SSL daughter card configurations through a direct connection to the CSM-S Certificate Management port (Cert. Mgt). After the initial configurations, you can make an SSH or Telnet connection to further configure the module. See Chapter 5 in the Catalyst 6500 Series Content Switching Module with SSL Installation and Configuration Note. LEDs When the CSM-S powers up, it initializes various hardware components and communicates with t

Summary of the content on the page No. 9

Environmental and System Requirements RJ-45 Connector The RJ-45 connector, which is covered by a removable plate, is used to connect a management station device or a test device. This connector is used by field engineers to perform testing and to obtain dump information. SSL Connector The Certificate Management (Cert. Mgt.) port connector is used for SSL certificate management and is available to make the necessary connection to the SSL daughter card for initial configuration purposes. Aft

Summary of the content on the page No. 10

Environmental and System Requirements System Requirements Before you install the CSM-S in the Catalyst 6500 series switch, make sure that the switch meets the hardware and software requirements listed in this section. Caution You can use the Multilayer Switch Feature Card (MSFC2), which is internal to the Catalyst 6500 series switch, to route traffic on either the client side or the server side of the CSM-S, but not both simultaneously (unless policy-based routing is used). Memory Requireme

Summary of the content on the page No. 11

Installing the CSM-S Software Requirements Caution The CSM-S release is not supported by the Catalyst operating system. Table 4 lists the software versions for the CSM-S. Table 4 CSM-S Software Requirements CSM-S Software Release Software Part Number Hardware Catalyst Operating System Cisco IOS Release 2,1(1) SC6K-1.1-CSM-S WS-X6066-SLB-S-K9 Not Applicable Cisco IOS software Release 12.2(18)SXD Software Compatibility The minimum software version that is listed is the minimum release that is r

Summary of the content on the page No. 12

Installing the CSM-S Preparing to Install the CSM-S Before installing the CSM-S, make sure that the following items are available: � Catalyst 6500 series switch chassis � Management station that is available through a Telnet or a console connection to perform configuration tasks Required Tools These tools are required to install the CSM-S in the Catalyst 6500 series switches: � Flat-blade screwdriver � Phillips-head screwdriver � Wrist strap or other grounding device � Antistatic mat or antis

Summary of the content on the page No. 13

Installing the CSM-S � Slot 1 is reserved for the supervisor engine. � Slot 2 can be used for a redundant supervisor engine if the supervisor engine in slot 1 fails. � If a redundant supervisor engine is not required, slots 2 through 6 on the 6-slot chassis, slots 2 through 9 on the 9-slot chassis, and slots 2 through 13 on the 13-slot chassis are available for switching modules, such as the CSM-S. � The empty slots require filler plates, which are blank switching-module carriers that mai

Summary of the content on the page No. 14

Installing the CSM-S Step 6 If the slot from which you removed the module is to remain empty, install a module filler plate to keep dust out of the chassis and to maintain proper airflow through the chassis. Warning Blank faceplates (filler panels) serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the

Summary of the content on the page No. 15

3 4 4 5 5 6 6 INPUT FAN OUTPUT INPUT FAN OUTPUT OK OK FAIL OK OK FAIL FAN STATUS WS-X6224 24 PORT 100FX WS-C6500-SFM SWITCH FABRIC MDL WS-X6K-SUP2-2GE Switch Load 100% PORT 1 PORT 2 CONSOLE PORT MODE CONSOLE PCMCIA EJECT 1% SUPERVISOR2 WS-X6K-SUP2-2GE Switch Load 100% PORT 1 PORT 2 CONSOLE PORT MODE CONSOLE PCMCIA EJECT 1% SUPERVISOR2 Installing the CSM-S Figure 2 Positioning the Module in a Horizontal Slot Chassis Insert module between slot guides EMI gasket 1 2 3 4 5 6 o EMI gas

Summary of the content on the page No. 16

3 4 4 5 5 6 6 WS-C6500-SFM SWITCH FABIRD MDL WS-X6224 24 PORT 100FX FAN STATUS WS-X6K-SUP2-2GE Switch Load 100% PORT 1 PORT 2 CONSOLE PORT MODE CONSOLE PCMCIA EJECT 1% SUPERVISOR2 WS-X6K-SUP2-2GE Switch Load 100% PORT 1 PORT 2 CONSOLE PORT MODE CONSOLE PCMCIA EJECT 1% SUPERVISOR2 Installing the CSM-S Figure 3 Clearing the EMI Gasket in a Horizontal Slot Chassis 1 2 3 Press down 4 Press down 5 6 1 mm Gap between the module EMI gasket and the module above it c. Using the thumb and f

Summary of the content on the page No. 17

WS-C6500-SFM SWITCH FABRIC MDL FAN STATUS WS-X6K-SUP2-2GE Switch Load 100% PORT 1 PORT 2 CONSOLE PORT MODE CONSOLE PCMCIA EJECT 1% SUPERVISOR2 WS-X6K-SUP2-2GE Switch Load 100% PORT 1 PORT 2 CONSOLE PORT MODE CONSOLE PCMCIA EJECT 1% SUPERVISOR2 Installing the CSM-S Figure 4 Ejector Lever Closure in a Horizontal Slot Chassis 1 2 3 4 5 6 Ejector levers flush with module faceplate Note Failure to fully seat the module in the backplane connector can result in system messages. e. Tighten

Summary of the content on the page No. 18

WS-C6500-SFM SWITCH FABRIC MDL 24 PORT 100FX WS-X6224 WS-X6K-SUP2-2GE Sw 100% itch Load PORT 1 PORT 2 CONSOLE PORT CONSOLE MODE PCMCIA EJECT 1% SUPERVISOR2 WS-X6K-SUP2-2GE Switch Load 100% PORT 1 PORT 2 CONSOLE PORT CONSOLE MODE PCMCIA EJECT 1% SUPERVISOR2 STATUS SYSTEM CONSOLE PWR MGMT RESET STATUS SYSTEM CONSOLE PWR MGMT RESET STATUS ACTIVE SE E EX L CT N T STATUS ACTIVE FA ST TUS INPUT FAN OUTPUT INPUT FAN OUTPUT OK OK FAIL OK OK FAIL N A Installing the CSM-S Figure 5 Positionin

Summary of the content on the page No. 19

WS-C6500-SFM SWITCH FABIRD MDL WS-X6224 24 PORT 100FX WS X6K SUP2 2GE 100%Sw ch Load PORT 1 PORT 2 CONSOLE PORT CONSOLE MODE PCMC A EJECT 1% SUPERVISOR2 - - - it I WS-X6K-SUP2-2GE Switch Load 100% PORT 1 PORT 2 CONSOLE PORT CONSOLE MODE PCMCIA EJECT 1% SUPERVISOR2 STATUS SYSTEM CONSOLE PWR MGMT RESET STATUS ACTIVE SELECT NEXT STATUS SYSTEM CONSOLE PWR MGMT RESET STATUS ACTIVE FA ST TUS INPUT FAN OUTPUT INPUT FAN OUTPUT OK OK FAIL OK OK FAIL N A Installing the CSM-S Figure 6 Cle

Summary of the content on the page No. 20

WS-X6224 24 PORT 100FX WS-X6K-SUP2-2GE Switch Load 100% PORT 1 PORT 2 CONSOLE PORT MODE CONSOLE PCMCIA EJECT 1% SUPERVISOR2 WS-X6K-SUP2-2GE Switch Load 100% PORT 1 PORT 2 CONSOLE PORT MODE CONSOLE PCMCIA EJECT 1% SUPERVISOR2 STATUS SYSTEM CONSOLE PWR MGMT RESET STATUS ACTIVE SELECT NEXT STATUS SYSTEM CONSOLE PWR MGMT RESET FAN STATUS Verifying the Installation Figure 7 Ejector Lever Closure in a Vertical Slot Chassis All ejector levers flush with module faceplate e. Tighten the two


Alternative user manuals
# User manual Category Download
1 Cisco Systems 11500 Series User manual Switch 13
2 Cisco Systems 11503 User manual Switch 3
3 Cisco Systems 11506 User manual Switch 1
4 Cisco Systems 11501 User manual Switch 1
5 Cisco Systems 116T User manual Switch 2
6 Cisco Systems 11500 User manual Switch 0
7 Cisco Systems 1503 User manual Switch 0
8 Cisco Systems 12006 User manual Switch 0
9 Cisco Systems 1548 User manual Switch 10
10 Cisco Systems 15454 User manual Switch 6
11 Cisco Systems 1900 User manual Switch 31
12 Cisco Systems 1800 User manual Switch 9
13 Cisco Systems 1538 User manual Switch 9
14 Cisco Systems 15600 User manual Switch 1
15 Cisco Systems 2900 User manual Switch 11
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4