Belkin OMNIVIEW P74696 user manual

User manual for the device Belkin OMNIVIEW P74696

Device: Belkin OMNIVIEW P74696
Category: Switch
Manufacturer: Belkin
Size: 7.4 MB
Added : 5/8/2013
Number of pages: 49
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Belkin OMNIVIEW P74696. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Belkin OMNIVIEW P74696.

For your convenience

If looking through the Belkin OMNIVIEW P74696 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Belkin OMNIVIEW P74696 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Belkin OMNIVIEW P74696 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Belkin OMNIVIEW P74696 User manual - Online PDF
Advertisement
« Page 1 of 49 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Belkin OMNIVIEW P74696 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Belkin OMNIVIEW P74696. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

® ®
OmniView ENTERPRISE OmniView ENTERPRISE
1U Rack-Mount Console with 1U Rack-Mount Console with
Built-In 8-Port KVM Switch Built-In 8-Port KVM Switch
Belkin Tech Support Belkin Ltd.
US: 310-898-1100 ext. 2263 7 Bowen Crescent, West Gosford
800-223-5546 ext. 2263 NSW 2250, Australia
Europe: 00 800 223 55 460 +61 (0) 2 4372 8600
Australia: 1800 235 546 +61 (0) 2 4372 8603 fax
New Zealand: 0800 235 546
Belkin B.V.
Belkin Corporation Boeing Avenue 333
501 West Walnut Street 1119 PH Schip

Summary of the content on the page No. 2

® ® OmniView ENTERPRISE OmniView ENTERPRISE 1U Rack-Mount Console with 1U Rack-Mount Console with Built-In 8-Port KVM Switch Built-In 8-Port KVM Switch Control your rack servers Control from a compact 1U rack-mount console User Manual F1DC108C

Summary of the content on the page No. 3

Table of Contents Table of Contents 1. Introduction ........................................................................................... 1 Package Contents ......................................................................... 1 2. Overview ............................................................................................... 2 Feature Overview .......................................................................... 2 Equipment Requirements ..............................

Summary of the content on the page No. 4

s se ec ct ti io on n Intr Introduction oduction P Package ackage Cont Contents ents 1 Package Contents: 2 3 1U Rack-Mount Rack-Mount IEC Power Two Console with Brackets with Cable Keys 4 KVM Switch Screws 5 6 Registration User Quick Card Manual Installation Guide 7 Congratulations on your purchase of this Belkin ENTERPRISE 1U Rack-Mount Console with Built-In 8-Port KVM Switch (the Rack-Mount Console KVM Switch*). Our diverse line of KVM solutions exemplifies the Belkin commitment t

Summary of the content on the page No. 5

Overview Feature Overview This User Manual will provide details about your new Rack-Mount Console KVM Switch, from installation and operation to troubleshooting—in the unlikely event of a problem. For quick and easy installation, please refer to the Quick Installation Guide included in your packaging. Thank you for purchasing the Belkin OmniView ENTERPRISE 1U Rack-Mount Console with Built-In 8-Port KVM Switch. We appreciate your business and have confidence that you will soon see for yours

Summary of the content on the page No. 6

section Overview Feature Overview • Video Resolution 1 The LCD supports SXGA video r esolutions of up to 1280x1024. 2 • Hot Keys Hot key functionality allows you to select a desired port using designated key commands. By using a simple hot key sequence on your keyboard, you can 3 select one server from as many as 256 servers, instantaneously. 4 • Reprogrammable Hot Key Initiator Sequence The Rack-Mount Console KVM Switch allows you to select up to six alternate keys to initiate hot key c

Summary of the content on the page No. 7

Overview Equipment Requirements Equipment Requirements Cables Connecting the Rack-Mount Console KVM Switch to a server requires custom Belkin OmniView ENTERPRISE Dual-Port Micro-Cabling. To connect multiple KVM Switches together, a custom Belkin OmniView ENTERPRISE Daisy-Chain Cable is required. F1D9400-XX (PS/2) OmniView ENTERPRISE Dual-Port Micro-Cabling F1D9400-XX (PS/2 Style) F1D9401-XX (USB Style) F1D9401-XX (USB) OmniView ENTERPRISE Daisy-Chain Cable F1D9402-XX (-XX denotes len

Summary of the content on the page No. 8

section Overview Operating System Requirements Operating System Requirements 1 The Rack-Mount Console KVM Switch is compatible with servers running on the 2 following platforms: ® ® • Windows 98, 2000, Me, NT , XP, 2003 3 ® ® • Red Hat Linux 7.0, 7.1, 7.2 • Mandrake • Linspire 4 ® ® • Novell NetWare 5.x, 6.x ® • MAC OS X v10.x 5 6 7 5

Summary of the content on the page No. 9

Overview Unit Display Diagrams Unit Display Diagrams OmniView ENTERPRISE 1U Rack-Mount Console with Built-In 8-Port KVM Switch LCD Handle Keylock LCD Mouse Drawer LCD Display Handle Buttons Keyboard Front Bracket Front View Flash Port Daisy-Chain Power Port, In Switch Optional Console Daisy-Chain 4 High-Density, 50-Pin, SCSI IEC Power PS/2 or USB Ports Port, Out 2-Style Computer Ports, each Connector Supporting 2 Servers Back View 6

Summary of the content on the page No. 10

section Overview LCD Display Buttons 1 LCD Display Buttons The Rack-Mount Console KVM Switch includes six buttons on the LCD 2 panel that allow you to adjust the settings on the display. The buttons are recessed in the panel to prevent accidental activation when the LCD 3 is folded down and stored. You will need to use a fine-tipped object to access the buttons. The table below provides the list of control functions for each button. 4 5 6 7 Activate settings menu; select/unselect Exit to pr

Summary of the content on the page No. 11

Overview Specifications Specifications Part No.: F1DC108C Max. Number of KVM Switches in Daisy-Chain: 16 Max. Number of Servers in Daisy-Chain: 248 Keyboard Emulation: PS/2 & USB Mouse Emulation: PS/2 & USB Server Ports: High-density, 50-pin, SCSI 2-style connector (requires Belkin OmniView ENTERPRISE Dual-Port Micro-Cabling) Max. LCD Resolution: 1280x1024 (SXGA) Keyboard Type: 106-key, PS/2-compatible Mouse Type: PS/2-compatible touch pad Enclosure: Metal enclosure Dimensio

Summary of the content on the page No. 12

section Installation Pre-Configuration 1 Pre-Configuration The enclosure of the Rack-Mount Console KVM Switch is designed for 2 rack-mount configuration in a standard 19-inch server rack. Rack-mount hardware is included for a sturdy rack installation. When deciding where to place the Rack-Mount Console KVM Switch, consider 3 the location of your servers and the length of cables needed to connect those servers to your Rack-Mount Console KVM Switch. 4 5 Cable Length Recommendations For PS/2

Summary of the content on the page No. 13

Installation Installing the Rack-Mount Console KVM Switch into a Server Rack Installing the Rack-Mount Console KVM Switch into a Server Rack Step 1 Remove the contents from the box. Step 2 Place the Rack-Mount Console KVM Switch on a rack and install the rack-mount brackets. 10

Summary of the content on the page No. 14

section Installation Installing the Rack-Mount Console KVM Switch into a Server Rack Step 3 1 Mount the Rack-Mount Console KVM Switch to your rack or cabinet. 2 3 4 5 6 7 Step 4 Connect the IEC power cable to an active power outlet and power up the Rack-Mount Console KVM Switch. 11

Summary of the content on the page No. 15

Installation Installing the Rack-Mount Console KVM Switch into a Server Rack Step 5 Unlock your Rack-Mount Console KVM Switch with keys provided. 12 12 12

Summary of the content on the page No. 16

section Installation Connecting Servers to the Rack-Mount Console KVM Switch (PS/2 Connection) 1 Connecting Servers to the Rack-Mount Console KVM Switch (PS/2 Connection) 2 Step 1 Using the OmniView ENTERPRISE Dual-Port Micro-Cabling (part number 3 F1D9400-XX, PS/2 style), connect the high-density, 50-pin, SCSI 2-style connector to a free Rack-Mount Console KVM Switch port, starting with the port for the first two servers. (For best results, screw the connectors into the 4 Rack-Mount C

Summary of the content on the page No. 17

Installation Connecting Servers to the Rack-Mount Console KVM Switch (USB Connection) Connecting Servers to the Rack-Mount Console KVM Switch (USB Connection) Step 1 Using the OmniView ENTERPRISE Dual-Port Micro-Cabling (part number F1D9401-XX, USB style), connect the high-density, 50-pin, SCSI 2-style connector to a free Rack-Mount Console KVM Switch port, starting with the port for the first two servers. (For best results, screw the connectors into the Rack-Mount Console KVM Switch an

Summary of the content on the page No. 18

section Installation Connecting Servers to the Rack-Mount Console KVM Switch (USB Connection) Step 4 1 Your server will detect the Rack-Mount Console KVM Switch as a generic mouse and keyboard. Older versions of Windows do not automatically install 2 USB HID devices, so you will have to manually press “Next” through the Windows Add/Remove Hardware Wizard until the HID devices are all installed (the Rack-Mount Console KVM Switch will install four devices: an HID keyboard, 3 an HID mou

Summary of the content on the page No. 19

Installation Connecting Multiple KVM Devices (Daisy-Chaining) Connecting Multiple KVM Devices (Daisy-Chaining) You can daisy-chain up to 15 additional Rack-Mount Console KVM Switches and other Belkin ENTERPRISE KVM Switches and Expanders together with your Rack-Mount Console KVM Switch. This will allow a server administrator to control up to a maximum of 248 servers. Each daisy-chained KVM device becomes a unit that is referred to as a “BANK” and is assigned an address. The first KVM switc

Summary of the content on the page No. 20

section Installation DIP Switch Configuration Chart 1 DIP Switch Configuration Chart DIP SWITCH # 2 BANK ADDRESS 1 2 3 4 Down Down Down Down BANK 00 (Default) 3 Up Down Down Down BANK 01 Primary/Secondary Down Up Down Down BANK 02 Secondary 4 Up Up Down Down BANK 03 Secondary 5 Down Down Up Down BANK 04 Secondary Up Down Up Down BANK 05 Secondary 6 Down Up Up Down BANK 06 Secondary Up Up Up Down BANK 07 Secondary 7 Down Down Down Up BANK 08 Secondary Up Down Down Up BANK 09 Secondary Down Up


Alternative user manuals
# User manual Category Download
1 Belkin F1D104 User manual Switch 12
2 Belkin 5232K User manual Switch 2
3 Belkin F1D5104P User manual Switch 5
4 Belkin BITRONICS P73046 User manual Switch 1
5 Belkin BITRONICS P72655 User manual Switch 1
6 Belkin 5216K User manual Switch 1
7 Belkin F1D5102T User manual Switch 0
8 Belkin F1DA104Z User manual Switch 2
9 Belkin F1D001 User manual Switch 1
10 Belkin F1DD102U, F1DD104U User manual Switch 6
11 Belkin F1DC108B User manual Switch 1
12 Belkin F1DJ102P-B User manual Switch 2
13 Belkin F1DF102P User manual Switch 4
14 Belkin F1DE101G User manual Switch 0
15 Belkin F1DD102LEA User manual Switch 12
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4