Summary of the content on the page No. 1
Installation Manual
SuperSmart
EtherHub-16se
Summary of the content on the page No. 2
Installation Manual SuperSmart EtherHub-16se Advanced 16-Port 10BASE-T Smart Ethernet Hub
Summary of the content on the page No. 3
Copyright (c) 1995 by Accton Technology Corporation. All rights reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of Accton Technology Corporation. Accton makes no warranties with respect to this documentation and disclaims any implied warranties of merchantability, quality, or fitness for any particular purpose. The information in this document is subject to change without notice. Accton reserves the right to make rev
Summary of the content on the page No. 4
FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications. Its op
Summary of the content on the page No. 5
Sicherheitshinweise 1. Die Steckdose muß sich in der Nähe des Gerätes befinden und leicht zugänglich sein. 2. Zum Reinigen den Stecker aus der Steckdose ziehen. Beim Reinigen keine Flüssigreiniger oder Sprays verwenden, sondern ein angefeuchtetes Tuch. 3. Das ...... gerät nicht in Naßräume oder in der Nähe von Wasser benutzen, wie z.B. Badezimmer, Schwimmbad, Spülbecken usw. . Das Eindringen von Wasser kann zur Zerstörung des Gerätes führen. 4. Das ...... gerät nicht auf einer unstabilen Unterla
Summary of the content on the page No. 6
About this Guide This is an installation guide for Accton’s SuperSmart Ethernet Hub. It covers the following topics: ì Hardware description and summary of features ì Hardware installation procedure ì System setup and configuration Package Checklist Carefully unpack the contents of the package and verify them against the checklist given below. æ EtherHub-16se (Model No. EH2051) æ One AC power cord æ 0.5 meter FlexBus 1500 cable æ Four rubber feet æ BNC T-type connector and two 50-ohm (Ω) termi
Summary of the content on the page No. 7
Contents Chapter 1: Introduction 1-1 Overview 1-1 Features of the SuperSmart Hub 1-2 Chapter 2: Hardware Description 2-1 Front Panel Display 2-1 SmartWatch LED Panel 2-1 PWR/CPU 2-2 Isolated 2-2 Utilization 2-2 Collision 2-3 Segment LED Indicators 2-4 Port Status Indicators 2-4 Partition 2-5 Link/Traffic 2-5 Diagnostic Test LED Indicators 2-6 Configure Button 2-7 Station Ports 2-8 Daisy-Chain Switch 2-8 Rear Panel Displays 2-9 Port Connections 2-9 FlexBus 1500™ 2-9 ALT Port
Summary of the content on the page No. 8
SuperSmart User’s Guide Chapter 4: Setup and Configuration 4-1 System Setup 4-1 Diagnostic Tests 4-1 Upon Power On 4-1 During Normal Operation 4-1 Multi-Segment Architecture 4-2 Hot Remove Function 4-2 Using the Configure Button 4-3 Selections Available 4-5 Appendix A: Product Specifications A-1 Features A-1 Physical Characteristics A-1 Standards Compliance A-2 Appendix B: Product Support Services B-1 Product Registration B-1 Problem Report B-1 Hardware Repair Service B-1 Software
Summary of the content on the page No. 9
List of Figures Figure 2.1 SmartWatch LED Panel 2-1 Figure 2.2 Daisy-Chain Switch Setting 2-8 Figure 2.3 The SuperSmart Rear Panel 2-9 Figure 3.1 Stacking Hubs without a Rack 3-3 Figure 3.2 Mounting Hubs Using a Mounting Rack 3-4 ix
Summary of the content on the page No. 10
Chapter 1: Introduction Overview The SuperSmart (EtherHub-16se) hub is a powerful and innovative LAN network enhancement product. This hub supports a multi-segment bus architecture that enhances traffic flow and network bandwidth utilization. It offers the network manager a wide range of flexible configuration options, allowing you to effectively increase your network’s bandwidth. The SuperSmart hub can be used in a stand-alone configuration to form a simple LAN networking 2 to 16 computers
Summary of the content on the page No. 11
SuperSmart User’s Guide Features of the SuperSmart Hub • One optional port (BNC, AUI or fiber-optic) for connecting to any Ethernet media via slide-in alternative module transceiver • Supports daisy chaining by using a daisy-chain switch to convert port 16 to a daisy-chain port • Automatic polarity detection and correction permits automatic recovery due to wiring errors • Automatically partitions any bad port to protect the network • Flexible installation for desktop, wall-mount, or rack insta
Summary of the content on the page No. 12
Chapter 2: Hardware Description This chapter describes the hardware features of the SuperSmart hub. Before connecting any network device to the hub, please read this chapter carefully. For easier management and control of the hub, familiarize yourself with the front panel indicators and Configure button. Front Panel Display SmartWatch LED Panel The SmartWatch LED panel includes comprehensive indicators for monitoring the device and network status. A quick glance at the front panel tells
Summary of the content on the page No. 13
SuperSmart User’s Guide PWR/CPU Color: Green Label: PWR/CPU Function: Power indicator LED Activity Condition Indication STEADY LIGHT ON Unit is receiving power; CPU is running. BLINKING LIGHT ON Unit is receiving power; CPU is running. NO LIGHT OFF Power is disconnected; no power received. Isolated Color: Green Label: Isolated Function: Indicates the hub is isolated from Ethernet segment of the FlexBus 1500 backplane. LED Activity Condition Indication STEADY LIGHT ON Hub is isolated from
Summary of the content on the page No. 14
SuperSmart User’s Guide For example, if network utilization reaches 1%, the LED labeled 1% will light. However, if network utilization rises above 1% (e.g., 30%), the LED labeled 30 and all the other LEDs before it (i.e., 1, 5, and 15) will light in rapid succession. These LEDs monitor the share of valid network frames transmitted by this hub within a 10Mbps bandwidth. They provide a quick way to monitor the current traffic load relative to the network’s capacity. Collision Label (%) Color F
Summary of the content on the page No. 15
SuperSmart User’s Guide When more than 31 consecutive collisions occur on the cable segment connected to a port, that port is automatically partitioned by the hub. The F hub automatically reconnects this port when a data packet longer than 512 bits (normal) is transmitted or received by the partitioned port without collision. This applies to all RJ-45 station ports and the ALT PORT. Segment LED Indicators Color: Green Label: Function: Indicates which segment is attached to the hub. There are
Summary of the content on the page No. 16
SuperSmart User’s Guide Partition LED Activity Condition Indication STEADY RED LIGHT PARTITION Indicates port partitioning due to an abnormal network condition. NO LIGHT OFF Port is in good condition. The Partition LEDs are also used as diagnostic LEDs. Please refer F to the section on Diagnostic Test LED Indicators later in this chapter for more information. Partition A port is temporarily partitioned when a line error or too many collisions are detected on the attached segment. While it is a
Summary of the content on the page No. 17
SuperSmart User’s Guide TROUBLESHOOTING If the Link/Traffic LED does not light up when a device is connected to its corresponding port, check that both the hub and connected device are powered on. For devices connected to the hub using a twisted-pair cable, check that the cable length does not exceed 100 meters. You should have standard, straight cables and not cross-over or other specialized cables. Traffic Traffic refers to the movement of packets being received by the port. A port’s corres
Summary of the content on the page No. 18
SuperSmart User’s Guide The system tests each component one at a time. The unit will complete the test cycle even if a problem is detected on any of the components. If no lights are ON, this means that all the hub components passed the diagnostics. If any problems were detected, the corresponding LED will blink after test completion to indicate which component failed the test. Configure Button On the left front panel is a button labeled Configure. Use this button for the following configur
Summary of the content on the page No. 19
SuperSmart User’s Guide Station Ports The unit has sixteen RJ-45 station ports. Using twisted-pair cable, connect your workstation (via the network interface card’s port) to any available RJ-45 port. Port 16 can be converted into a daisy-chain port by enabling the Daisy-Chain switch (see the following Daisy-Chain Switch section for related information). Hence, this port can also be used to connect the unit to another compatible unit using twisted-pair cable. Daisy-Chain Switch This switch
Summary of the content on the page No. 20
SuperSmart User’s Guide Rear Panel Displays This section describes significant features of the unit’s rear panel. POWER POWER Alternative Port SWITCH SOCKET Connectors ALT PORT ON This device complies with Part 15 of the FCC FlexBus 1500 Operation is subject to the following two (1) This device may not cause harmful 100-250 VAC (2) This device must accept any interference OFF including interference that may cause 50 -60Hz 1A IN OUT Figure 2.3 The SuperSmart Rear Panel Por