Summary of the content on the page No. 1
Photoelectric Safety Sensors
Installation Instructions
and Owner’s Manual
Wayne-Dalton Corp.
P.O. Box 67 Mt. Hope, OH 44660
(888) 827-3667
Opener Models:
www.wayne-dalton.com
Torsion idrive™ models: 3651-372, 3750-372.
Quantum™/Classicdrive™ models: 3012, 3014, 3016, 3018, 3212, 3213, 3214, 3312, 3313, 3314, 3316, 3412, 3414, 3512, 3514.
DoorMaster™ models: BDOR-2000 & BIRW-2000
idrive™ models: 3660-372, 3661-372, 3662-372, 3760-372, 3751-372.
WIRES ARE
PRE-ATTACHED
Photoelectric Sensors Hardwa
Summary of the content on the page No. 2
Table of Contents ○○○○ ○○○○○○○○ Important Safety Instructions For Installation And Use 2. ○○○○○○○○○○○○○○○○○○○○○○○○ ○○○○○○○○○○○○○○ Bracket Installation 3. ○○○○○○○○○○○○ ○○○○○ Wiring Installation “Quantum™/Classicdrive™” 4. ○○○○ ○○○○○○○○○○○○○○○○○○○○○○○○ Wiring Installation “DoorMaster™” 4. ○○○○○○○○○○○○○○○○○○ ○○○○○○○○○○○○○○ Wiring Installation “idrive™” 5. ○○○○○○○○○○○ ○○○○○○○○○○○○○○○ Wiring Installation “Torsion idrive™” 5. ○○○○○○○○○○○○○○○ ○○○○○○○○○ Photoelectric Safety Sensor Alignment 6. ○○○○ ○○○○
Summary of the content on the page No. 3
Step 1: Photoelectric Safety Sensor Bracket Installation WARNING DISCONNECT ALL POWER TO “U” BRACKETS GARAGE DOOR OPENER BEFORE SERVICING OR INSTALLING ACCESSORIES OR PHOTOELECTRIC SAFETY SENSORS. FOR ALL OPENERS, UNPLUG 120 V AC POWER CORD FROM RECEPTACLE. FOR DOORMASTER, ALSO UNPLUG TELEPHONE CORD TYPE COMMUNICATIONS CABLE. Select a mounting position, no more than 5 inches above the WALL MOUNTING BRACKETS floor to center line of wall mounting bracket. The sending and receiving units sh
Summary of the content on the page No. 4
Step 2: Photoelectric Safety Sensor Wiring Installation For: Quantum™/Classicdrive™ models: 3012, 3014, 3016, 3018, 3212, 3213, 3214, 3312, 3313, 3314, 3316, 3412, 3414, 3512, 3514. Uncoil wires from the photoelectric sensors and route wires up the garage walls and along ceiling towards the right side of the opener (see Fig. 1). Route wires behind torque tube and tack wires in place Opener with insulated staples (not supplied). Take care to run wires in a location where they will not interfere
Summary of the content on the page No. 5
Step 2: Photoelectric Safety Sensor Wiring Installation For: idrive™ models: 3660-372, 3661-372, 3662-372, 3760-372, 3751-372. Uncoil wires from photoelectric sensors and route wires up garage wall and along door header towards the right side of the opener (see Fig. 3 ). Route wires behind torque tube and tack wires in place with insulated staples (not supplied).Take care to run wires in a location where they will not interfere with the operation of the door and do not staple through wire. Conn
Summary of the content on the page No. 6
Step 3: Photoelectric Safety Sensor Alignment IMPORTANT! - This infrared safety sensor sends an invisible FIG.5 beam of light from the sending unit to the receiving unit across IN IN the door opening. The door opener will not operate until the 1/4-20 Carriage bolts safety sensor is connected to the power unit and properly Top View aligned. If the invisible beam of light is misaligned or obstructed, an open door cannot be closed by the transmitter or a momentary Align In Center activation of the
Summary of the content on the page No. 7
IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH: Please thoroughly read safety rules on Page 2 and the following operating instructions. Operate only when opener is properly adjusted and the door is visible and unobstructed. Never let children operate or play with Always keep moving door insight and keep door controls. Keep remote control away people and objects away from the door from children until it is completely closed. NO ONE Test door opener monthly. O