Thermo Products USDT 2004B user manual

User manual for the device Thermo Products USDT 2004B

Device: Thermo Products USDT 2004B
Category: Stud Sensor
Manufacturer: Thermo Products
Size: 0.5 MB
Added : 2/4/2014
Number of pages: 10
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Thermo Products USDT 2004B. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Thermo Products USDT 2004B.

For your convenience

If looking through the Thermo Products USDT 2004B user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Thermo Products USDT 2004B on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Thermo Products USDT 2004B to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Thermo Products USDT 2004B User manual - Online PDF
Advertisement
« Page 1 of 10 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Thermo Products USDT 2004B but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Thermo Products USDT 2004B. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

USDT 2004B
Installation and User’s Guide


Introduction
General Information 2

Installation
Collector Sensor 3
Control Box 5
Power Connection 6
Display Window 6

Operation
Basic Operation of Digital Display 6
Programming the Temperature Range 8
Manual Operation Mode 9
Troubleshooting 10


Thermo Technologies
5560 Sterrett Place • Suite 115
Columbia, Maryland 21044
Phone 410.997.0778 • Fax 410.997.0779
e-Mail info@the

Summary of the content on the page No. 2

Introduction Note: The information supplied in this manual is for guidance only - no part of this may be used for any agreement, whether express or implied, or to form any contract. Thermo Technologies reserves the right to change specifications without prior notice. SDT 2004B is a powerful temperature differential control unit. It uses two temperature U sensors to control a simple solar water heating system; one sensor measures the temperature of the solar collector whilst th

Summary of the content on the page No. 3

INSTALLATION Note: This installation procedure is for guidance only, and the installer should verify its suitability. Make sure that the solar system is physically installed, manually tested, and ready for controlled operation. he following safety precautions is strongly recommended: T 1. Before attempting to install and operate the unit read this instruction manual carefully. 2. Only suitably qualified personnel should carry out installation and required maintenanc

Summary of the content on the page No. 4

l Collector sensor (red cable with protective terminal box): Either push into a thermowell, (sensor pocket), which is soldered or riveted directly to the manifold (vacuum tubes). Alternately, strap the sensor to the collector outlet pipe or the absorber (flat plate collectors) that projects from the collector housing. Ideally, house the collector sensor (encased in a suitable sensor pocket) into a T-piece on the collector return outlet. Protect the sensor cable from UV and moisture.

Summary of the content on the page No. 5

Undo the screw at the top of the housing. The control electronics are mounted on the enclosure cover. The controller enclosure can be screwed to the wall with cable entry grommets pointed downwards. Use the supplied plastic bridges to secure power and sensor cables. Base of the unit to be mounted at eye-level and wired as shown above Caution: Controller wiring should only be done when the unit is not energized. It is possible to damage the control unit if it is assembled un

Summary of the content on the page No. 6

ower Connections: A small blade screwdriver may be used to fasten miniaturized P terminal block screws while the corresponding wire is inserted. NOTE 1: Always disconnect the controller from power supply before opening the housing. NOTE 2: The controller should be properly grounded. Flexible wires, 18/3 AWG (gauge/conductor) simplify connection to the terminals. The power terminal block will accommodate wire sizes to 14 AWG. All other connections should be secured and adequa

Summary of the content on the page No. 7

ò Push selection key once to enter the advanced (Par or *Men) mode. Once in selected mode, press one more time to select the parameter in that mode. Selected parameter blinks allowing the user to modify it. You can modify the selected parameter while the middle window blinks by pressing the ï or ð key. ñ Push selection key once to accept selection (blinking stops showing the new set-point steady) or go back to the previous selection. (*) USDT 2004B does not support “Men” mode oper

Summary of the content on the page No. 8

Par Using the navigation key ^_ allows you to select the desired parameter while you are in the program mode. Press the selection key ò once to select the parameter in the window. Selected parameter blinks allowing you to modify it. You can modify the selected parameter while the middle window blinks by pressing the ï or ð key. The unit accepts the new value by pressing the ñ key once. RUV 2.0 – This display shows the software revision number. NR O – This indicates the USDT 20

Summary of the content on the page No. 9

Manual Operation Mode This mode allows the user to manually turn the pump on or off. AUTO The above display indicates that the unit is working in automatic mode. The o pump starts at a temperature difference of 15 F and runs as long as ? T is o above 7 F. The B symbol appears in upper display line next to the collector symbol while the pump is running. User can switch to manual mode by pressing ò key. By pressing ð key while centerline blinks, a hand symbol G in lower lin

Summary of the content on the page No. 10

roubleshooting T In general, all of the settings in the menus Par and Men and the terminal should first be checked if there is a malfunction. Malfunction, but "realistic" temperature values: • Check program number. It should be “0” (zero) for 2004B unit. • Check the switch-on and switch-off thresholds and the set differential temperatures, page 8. Have the thermostat and differential thresholds already been reached? • Can the pump (output) be switched on and off in manual mode? I


Alternative user manuals
# User manual Category Download
1 Thermo Products USDT2004 User manual Stud Sensor 0
2 A&D sf/sg User manual Stud Sensor 2
3 Sony ICX423AL User manual Stud Sensor 1
4 Sony E01X23A41 User manual Stud Sensor 1
5 Sony ICX418ALB User manual Stud Sensor 1
6 Agilent Technologies 81680A User manual Stud Sensor 3
7 Agilent Technologies 81689A User manual Stud Sensor 3
8 Agilent Technologies 81480A User manual Stud Sensor 1
9 Agilent Technologies 85037-90013 User manual Stud Sensor 2
10 Agilent Technologies 81682A User manual Stud Sensor 2
11 Agilent Technologies 81640A User manual Stud Sensor 1
12 Agilent Technologies 4A User manual Stud Sensor 1
13 Agilent Technologies E9300 User manual Stud Sensor 1
14 Agilent Technologies 3A User manual Stud Sensor 1
15 Agilent Technologies 81632A User manual Stud Sensor 10