Siemens E12 user manual

User manual for the device Siemens E12

Device: Siemens E12
Category: Stud Sensor
Manufacturer: Siemens
Size: 3.56 MB
Added : 2/4/2014
Number of pages: 47
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Siemens E12. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Siemens E12.

For your convenience

If looking through the Siemens E12 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Siemens E12 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Siemens E12 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Siemens E12 User manual - Online PDF
Advertisement
« Page 1 of 47 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Siemens E12 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Siemens E12. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Industry Automation and Drive Technologies - SCE















Training Manual for Integrated Automation
Solutions
Totally Integrated Automation (TIA)

MODULE E12
VISION SENSOR Shape Checking
with SIMATIC S7-300F-2 PN/DP and VS120







TIA Training Document Page 1 of 47 Module
E12
Status: 01/2010 Vision Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120

Summary of the content on the page No. 2

Industry Automation and Drive Technologies - SCE This manual was prepared for training purposes by Siemens AG for the project Siemens Automation Cooperates with Education (SCE). Siemens AG does not guarantee the contents of this document. Passing on this document as well as copying it, using and communicating its contents is permitted within public training and continued education facilities. Excep

Summary of the content on the page No. 3

Industry Automation and Drive Technologies - SCE PAGE 1. Preface.....................................................................................................Fehler! Textmarke nicht definiert. 2. Notes on using the CPU 315F-2 PN/DP .........................................................................................................7 3. Notes on the SIMATIC VS120 components................................................................................................

Summary of the content on the page No. 4

Industry Automation and Drive Technologies - SCE The following symbols serve as a guide through Module E12: Information Programming Sample Task Notes TIA Training Document Page 4 of 47 Module E12 Status: 01/2010 Vision Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120

Summary of the content on the page No. 5

Industry Automation and Drive Technologies - SCE 1 PREFACE Regarding its content, Module E12 is part of the instruction unit ’IT Communication with S7’. Fundamentals of STEP7 Programming 2 to 3 days Modules A Additional Functions of System Simulation STEP7 Programming with SIMIT SCE 2 to 3 days Modules B 1 to 2 days Modules G Programming Industrial Fieldbus Process Languages Systems Visualization 2 to 3 days Modules F 2 to 3 days

Summary of the content on the page No. 6

Industry Automation and Drive Technologies - SCE Hardware and software required 1 PC, operating system Windows XP Professional with SP2 or SP3/Vista 32 Bit Ultimate and Business/Server 2003 SP2 with 600MHz (only XP)/1 GHz and 512MB (only XP)/1 GB RAM, free disk storage approx. 650 to 900 MB, MS Internet Explorer 6.0 and network card 2 Software STEP 7 V 5.4 3 SPS SIMATIC S7300 with CPU 315F-2 PN/DP and at least one digital input and output module. Sample configuration: -

Summary of the content on the page No. 7

Industry Automation and Drive Technologies - SCE 2 NOTES ON USING THE CPU 315F-2 PN/DP The CPU 315F-2 PN/DP is a CPU that is shipped with 2 integrated interfaces. - The first interface is a combined MPI/PROFIBUS DP interface that can be used at the PROFIBUS DP as master or slave to connect distributed IO/field devices with very fast reaction time. In addition, it is possible to program the CPU here by means of an MPI or PROFIBUS DP - The second interface is an i

Summary of the content on the page No. 8

Industry Automation and Drive Technologies - SCE 3.2 Performance Features • Incident light method with LED ring lamp • Object recognition with object search and object check • Startup by means of setup support at the PG/PC with installed Internet Explorer • Up to 20 object checks per second • Up to 64 objects to be checked can be stored • To sort the objects to be checked, 2 digital outputs are provided: OK, N_OK • Operator interface is completely Web-based • Extensive o

Summary of the content on the page No. 9

Industry Automation and Drive Technologies - SCE 3.4 Recording and Reading Out Recognition Values in a PROFINET IO Environment • By means of the Ethernet (TCP/IP) and a switch, a PC/PG is connected that is used exclusive for the setup process. • By means of the Ethernet and a switch, a connection exists to an automation systems with PROFINET IO capability. • The SIMATIC VS120 is controlled by the automation system. • The result of the objects to be checked is read out via

Summary of the content on the page No. 10

Industry Automation and Drive Technologies - SCE 3.5 Setting the Communication Interface of the VS120 to PROFINET First, switch on the power supply of the evaluation device VS120 for the initial startup. At the initial startup, "Factory Settings Used" appears on the LCD display. Confirm with "OK". The VS120 will then perform a self test: • Checking the Ethernet connection Press ESC • Functional check of the sensor head Press ESC After completion of the self te

Summary of the content on the page No. 11

Industry Automation and Drive Technologies - SCE "Connect" Menu: The Ethernet IP mode has to be set to PNIO. Place the cursor in front of Ports and press the OK button Place the cursor in front of Ethernet and press the OK button Place the cursor in front of IP Mode and press the OK button Place the cursor in front of PNIO and press the OK button The evaluation device now requests a restart; press the OK button to confirm. After the restart, the red bus error LED

Summary of the content on the page No. 12

Industry Automation and Drive Technologies - SCE 4 STARTING UP A PROJECT WITH CPU 315F-2 PN/DP AND VS120 Below, starting up the VS120 in a project is described. As SIMATIC S7-300 Station, the CPU 315F-2 PN/DP is used. In the CPU’s control program, a data structure has to be generated by means of a function block call (FB1) with data block (DB10). The data structure looks like this: FB1 DB10 for VS120 Result of the form checl Instance DB1 of FB1 All additional inf

Summary of the content on the page No. 13

Industry Automation and Drive Technologies - SCE 4.1 Setting Up a New Project 1. The central tool in STEP 7 is the ’SIMATIC Manager’. It is called here with a double click (→ SIMATIC Manager) 2. STEP7 programs are managed in projects. We are now setting up such a project (→ File → New) 3. Now, the project is assigned the ’Name’ ’VS120’ (→ VS120 → OK) TIA Training Document Page 13 of 47 Module E12 Status: 01/2010

Summary of the content on the page No. 14

Industry Automation and Drive Technologies - SCE 4. Next, highlight your project and insert an ’Industrial Ethernet Subnet’. (→ VS120 → Insert → Subnet → Industrial Ethernet). 5. Now, a ’SIMATIC 300 Station’ is inserted (→ Insert → Station → SIMATIC300 Station) TIA Training Document Page 14 of 47 Module E12 Status: 01/2010 Vision Sensor Shape Check with SIMATIC S7-300F 2PN/

Summary of the content on the page No. 15

Industry Automation and Drive Technologies - SCE 4.2 Configuring the Hardware 6. With a double click, open the configuration tool for the ’Hardware’. (→ Hardware) 7. Open the hardware catalog by clicking on the symbol ' ’. (→ ) Insert the ’Mounting Channel’ with a double click (→ SIMATIC 300 → RACK-300 → Mounting Channel). Note: Then, a configuration table is displayed automatically for setting up Rack 0. TIA Training Document Page 15 of 47 Module E

Summary of the content on the page No. 16

Industry Automation and Drive Technologies - SCE 8. Now, from the hardware catalog select all modules that are also inserted in your actual rack and place them in the configuration table. To this end, click on the name of the respective module, hold the mouse key and drag it to a line in the configuration table. We start with the power supply ’PS 307 5A’ (→ SIMATIC 300 → PS-300 → PS 307 5A) Note: If your hardware differs from the one shown here, simply select the c

Summary of the content on the page No. 17

Industry Automation and Drive Technologies - SCE 9. Next, we drag the ’CPU 315F-2 PN/DP’ to the second slot. The CPU’s order number and the version are provided on the front of the CPU. (→ SIMATIC 300 → CPU-300 → CPU 315F-2 PN/DP → 6ES7 315-2FH13-0AB0 → V2.6) 10. When entering the CPU, the window below is displayed. In this window, do the following: assign to the CPU 315F-2 PN/DP an ’IP Address’, specify the ’Subnet screen form’ and select the ’Ethernet’ that is already

Summary of the content on the page No. 18

Industry Automation and Drive Technologies - SCE Notes regarding networking on the Ethernet (additional information is provided in Appendix V of the training manual): MAC address: The MAC address consists of a permanent and a variable part. The permanent part ("Basic MAC address") identifies the manufacturer (Siemens, 3COM, ...). The variable part of the MAC address differentiates the different Ethernet stations and should be assigned globally unique. On each module, a MAC

Summary of the content on the page No. 19

Industry Automation and Drive Technologies - SCE 11. Next, we drag the input module for 16 inputs to the 4th slot. The module’s order number is inscribed on the front. (→ SIMATIC 300 → DI-300 → SM 321 DI16x24VDC). Note: Slot 3 is reserved for interface modules and remains empty for that reason. The module’s order number is shown in the footer of the catalog. TIA Training Document Page 19 of 47 Module E12 Status: 01/2010

Summary of the content on the page No. 20

Industry Automation and Drive Technologies - SCE 12. Then, we drag the output module for the 16 outputs to the 5th slot. The module’s order number is inscribed on the front. (→ SIMATIC-300 → DO-300 → SM 322 DO16x24VDC/0.5A). Note: The module’s order number is shown in the footer of the catalog. 13. Now, we have to change the PROFINET device name to PN-IOx100. Select ’PN-IO’ with a double click (→ PN-IO,→ PN-IOx100,→ OK) TIA Training Document Page 20 of 47


Alternative user manuals
# User manual Category Download
1 A&D sf/sg User manual Stud Sensor 2
2 Sony ICX423AL User manual Stud Sensor 1
3 Sony E01X23A41 User manual Stud Sensor 1
4 Sony ICX418ALB User manual Stud Sensor 1
5 Agilent Technologies 81680A User manual Stud Sensor 3
6 Agilent Technologies 81689A User manual Stud Sensor 3
7 Agilent Technologies 81480A User manual Stud Sensor 1
8 Agilent Technologies 85037-90013 User manual Stud Sensor 2
9 Agilent Technologies 81682A User manual Stud Sensor 2
10 Agilent Technologies 81640A User manual Stud Sensor 1
11 Agilent Technologies 4A User manual Stud Sensor 1
12 Agilent Technologies E9300 User manual Stud Sensor 1
13 Agilent Technologies 3A User manual Stud Sensor 1
14 Agilent Technologies 81632A User manual Stud Sensor 10
15 Agilent Technologies 81642A User manual Stud Sensor 1