Omega FTB600B user manual

User manual for the device Omega FTB600B

Device: Omega FTB600B
Category: Stud Sensor
Manufacturer: Omega
Size: 0.43 MB
Added : 6/25/2014
Number of pages: 26
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Omega FTB600B. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Omega FTB600B.

For your convenience

If looking through the Omega FTB600B user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Omega FTB600B on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Omega FTB600B to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Omega FTB600B User manual - Online PDF
Advertisement
« Page 1 of 26 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Omega FTB600B but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Omega FTB600B. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

User’s Guide
Shop online at
omega.com
e-mail: info@omega.com
For latest product manuals:
omegamanual.info
FTB600B Series
Ultra-Low Flow Sensors

Summary of the content on the page No. 2

® OMEGAnet On-Line Service Internet e-mail omega.com info@omega.com Servicing North America: Canada: U.S.A.: ISO 9001 Certified 976 Bergar One Omega Drive, Box 4047 Laval (Quebec) H7L 5A1, Canada Stamford, CT 06907-0047 Tel: (514) 856-6928 Tel: (203) 359-1660 FAX: (514) 856-6886 FAX: (203) 359-7700 e-mail: info@omega.ca e-mail: info@omega.com For immediate technical or application assistance: U.S.A. and Canada: Mexico: ® ~ Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA En Espanol: (001) 203-359

Summary of the content on the page No. 3

FTB600B Series TABLE OF CONTENTS Ultra-Low Flow Sensors Section Page Section 1 Introduction ...................................................................... 1 A. General Description .................................................... 1 B. Principle of Operation ................................................. 1 C. Material Characteristics of PVDF ............................... 2 Section 2 Operation Parameters ..................................................... 3 A. Temperature ......

Summary of the content on the page No. 4

FTB600B Series Ultra-Low Flow Sensors NOTES: ii

Summary of the content on the page No. 5

FTB600B Series Installation 1 IMPORTANT: READ INSTRUCTIONS THOROUGHLY BEFORE INSTALLING FLOW METER Section 1 - Introduction A. General Description The FTB600B Series is an axial paddle wheel turbine type flow meter based on the pelton wheel principle. This unique patented design makes the FTB600B Series a very accurate, repeatable, linear device. Not only is the FTB600B Series precise, but it is also a rugged, trouble- free flow meter, which can be used in a wide variety of industries including:

Summary of the content on the page No. 6

FTB600B Series 1 Installation C. Material Characteristics of PVDF (Polyvinylidene Fluoride) 1. Material of construction Trade name - Kynar All wetted parts of the FTB600B Series are PVDF, excluding the O-ring. Wetted parts include any part of the meter that will or could come in contact with the fluid. List of wetted parts: 1. Barbed fittings 5. End caps 2. Flow meter body 6. Strainer 3. Rotor 7. Bearings 4. Helical nozzle (Viton O-ring seal) 2. Chemical Composition Polyvinylidene Fluoride is a

Summary of the content on the page No. 7

FTB600B Series Operating Parameters 2 Section 2. - Operating Parameters A. Temperature Since the FTB600B Series has printed circuit boards molded into the body of the meter it is strongly recommended that 180°F not be exceeded. Exceeding 180°F can cause irreparable damage to the circuit boards. B. Flow Ranges The FTB600B Series is available in six different sizes, which cover a flow range from 0.1 to 120 lpm. Specific flow ranges FTB601B 0.1 to 2 lpm (0.03 to 0.53 gpm) FTB602B 0.3 to 9 lpm (0.0

Summary of the content on the page No. 8

FTB600B Series 2 Operation Parameters 4

Summary of the content on the page No. 9

FTB600B Series 2 Operating Parameters C. Recommended Viscosity Range 1-5 cSt (w/o correction) The effects of changing viscosity on the FTB600B Series are the same as any other turbine flow meter. It is important to remember that a turbine meter is a viscosity dependent device, where as the viscosity increases the linearity of the flow meter will decrease. (Water like viscosities are ideally suited for use with the FTB600B Series) The FTB600B Series is factory calibrated with water. Correction pr

Summary of the content on the page No. 10

FTB600B Series Silicone Treatment 3 Section 3 - Silicone Treatment Silicone treatment is standard for all types of the FTB600B Series series electronics. 6

Summary of the content on the page No. 11

FTB600B Series Infrared Sensors 4 Section 4 - Infrared Sensor A. Supply Voltage 24 Vdc. Do not exceed 24 Vdc. Doing so can cause overheating and eventual failure of all PC boards. Printed circuit boards are non- repairable. B. Frequency Output 1. Square wave pulse, unscaled (See Figure 4-1) 2. Output impedance 75 ohms 3. Directly proportional to flow rate 4. Output - dc frequency 5. Offset 0.64 volts 6. Peak voltage = Supply voltage - 1.2 volts 7. Peak to peak voltage Supply voltage - 1.2 volts

Summary of the content on the page No. 12

FTB600B Series 4 Infrared Sensors C. Frequency Ranges for (non-cartridge models) pulses/l Model Frequency (Hz) K-Factor FTB601B 60 to 1200 36,000 FTB602B 40 to 1200 8,000 FTB603B 27 to 800 3,200 FTB604B 20 to 600 1,200 FTB605B 18.75 to 562 450 FTB606B 15 to 450 225 D. Cable Requirements 1. 20 to 22 AWG (American Wire Gauge) 2. 4 conductor-shielded cable. NOTE Avoid influences of strong electromagnetic forces as they can damage components on the PC boards. 8

Summary of the content on the page No. 13

FTB600B Series 4 Infrared Sensors Figure 4-1. Output Frequency Waveforms 9

Summary of the content on the page No. 14

FTB600B Series Installation 5 Section 5 - Installing the FTB600B Series in the fluid line. A. Make sure the fluid is compatible with PVDF (polyvinylidene fluoride) and meets viscosity, pressure and temperature parameters of the FTB600B Series. The fluid must also meet filtration requirements as listed in 3D. B. Install the FTB600B series in the fluid line with the arrow pointing in the direction of the flow. C. While installing the FTB600B Series in the fluid line be careful not to over-torque t

Summary of the content on the page No. 15

FTB600B Series 5 Installation Figure 5-1. Supply Voltage and Signal Output Connections 11

Summary of the content on the page No. 16

FTB600B Series 5 Installation Table 5-1. Piping Table 12

Summary of the content on the page No. 17

FTB600B Series 5 Installation Table 5-1. Piping Table Con't. 13

Summary of the content on the page No. 18

FTB600B Series Specifications 6 Section 6 - Specifications Accuracy: ±3% of reading Repeatability: ±0.1% of reading Linearity: ±1% of reading Viscosity Range: 1 to 15 centistokes Working Pressure: 150 PSIG at 175°F Wetted Materials: PVDF Power Supply: 5 to 18 Vdc, 6 to 33 mA Output Signal: Unscaled square wave Pressure Drop: See Section 7 14

Summary of the content on the page No. 19

FTB600B Series Pressure Drop Curves 7 Section 7 - Pressure Drop Curves Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB601 50 45 40 35 30 25 20 15 10 5 0 0 0.5 1.0 1.5 2.0 Liters/minute 15 kPa

Summary of the content on the page No. 20

FTB600B Series 7 Pressure Drop Curves Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB602 250 200 150 100 50 0 0 2.0 4.0 6.0 8.0 10.0 Liters/minute 16 kPa


Alternative user manuals
# User manual Category Download
1 Omega CDTX-90 User manual Stud Sensor 12
2 Omega DMD-476 User manual Stud Sensor 0
3 Omega CNiS16D User manual Stud Sensor 0
4 Omega CNiS8C User manual Stud Sensor 0
5 Omega CNiS8 User manual Stud Sensor 0
6 Omega CNiS8DV User manual Stud Sensor 0
7 Omega CNiS16 User manual Stud Sensor 0
8 Omega CNiS32 User manual Stud Sensor 0
9 Omega FCLTX-100 User manual Stud Sensor 0
10 Omega CNiS8DH User manual Stud Sensor 0
11 Omega LV800 User manual Stud Sensor 0
12 Omega OS35 User manual Stud Sensor 2
13 Omega CDE683 User manual Stud Sensor 0
14 A&D sf/sg User manual Stud Sensor 2
15 Sony ICX423AL User manual Stud Sensor 1
16 Sony E01X23A41 User manual Stud Sensor 1
17 Sony ICX418ALB User manual Stud Sensor 1
18 Agilent Technologies 81680A User manual Stud Sensor 3